File Nr. 3900.18-450.113.16 | Revision: 201710
IEC60115-1 clause 4.13
(U=2,5* , ≤2* Umax, 5 [s])
±[%] 0,03 (≤1M) ; 0,1 (>1M) 0,03 (≤1M) ; 0,15 (>1M)
0,05 (≤1M) ; 0,1 (>1M) 0,05 (≤1M) ; 0,15 (>1M)
Single pulse high voltage overload
IEC60115-1 clause 4.27
(U=10*
Severity 4, 10 pulses 10[µs]/700[µ
±[%] 0,15 0,25
Power
operation 0,15 0,5
Periodic electric overload
IEC60115-1 clause 4.39
(U=15*
0.1[s]on, 2.5[s]off,1000 cycles
Standard
operation ±[%] 0,15 0,15
0,3 0,3
Failure Rate
(Total, ϑ0 , max, 60[%] cont. lev.)
[10-9 h-1] ≤ 0,1
Endurance at 70ºC,
IEC60115-1 clause 4.25.1
(U= Umax,, 1,5[h]ON ; 0,5[h]OFF)
Precision
operation ±[%]
Standard
operation ±[%]
0.15 (<10R) ; 0.1 (10R≤1M) ; 0.25 (>1M)
0.3 (<10R) ; 0.2 (10R≤1M) ; 0.5 (>1M)
Power
operation ±[%]
Endurance at upper Category Temp.
IEC60115-1 clause 4.25.3
±[%] 125ºC 0.15 (<10R) ; 0.1 (10R≤1M) ; 0.25 (>1M) 0,15 (≤1M) ; 0,5 (>1M)
0.3 (<10R) ; 0.2 (10R≤1M) ; 0.5 (>1M)
Damp Heat, Steady State
IEC60115-1 clause 4.24
(40±2[°C], 93±3[% r.h.], 56[d])
±[%] 0,15 (≤ 1M) ; 0,25 (>1M) 0,25 (≤ 1M) ; 1 (>1M)
Damp Heat, Steady State, Accelerated
IEC60115-1 clause 4.37
(85±2[°C], 85±5[%RH], U = 0.3*
)
±[%] 0,25 (≤ 1M) ; 2 (>1M) 0,5 (≤ 1M) ; 2 (>1M)
IEC60068-2-14 ; IEC60115-1 clause 4.19
( 30[min] each , 1000 cycles)
±[%]
-55~155ºC 0,5 0,5
IEC60068-2-6 ; IEC60115-1 clause 4.22
(10;2000[Hz], ≤1,5[mm] , or ≤200[m/s
2
±[%] 0,05 (≤ 1M) ; 0,1 (>1M) 0,05
Resistance to Soldering Heat
IEC60115-1 clause 4.18
(260±5 [°C], 10±1[s])Solder bath method
±[%] 0,1 (≤ 10R) ; 0,05 (>10R) 0,1 (≤ 10R) ; 0,05 (>10R)
IEC60115-1 clause 4.38 ; IEC61340-3-1
( 3 positives + 3 negatives discharges)
±[%] 0,5 [2 kV] 0,5 [4 kV]
IEC60115-1 clause 4.7
No flash over or breakdown
IEC60115-1 clause 4.35, IEC60695-11-5
No burning after 30[s]
IEC60068-2-20 ; IEC60115-1 clause 4.17
±3
±0,2
[s],SnAg3Cu0.5 or SnAg3 .5)
≥ 95% covered, no visible damage
Component Resistance to Solvents
IEC60068-2-45 ; IEC60115-1 clause 4.29
(50[ºC] method 2)
No visible damage
Resistance to solvents of Marking
IEC60068-2-45 ; IEC60115-1 clause 4.30
(50[ºC] method 1)
Marking visible , no visible damage
Color code
NOTES: MARKING [COLOR CODE]:
•
ZCM204 Color code marking is applied according to IEC 60062 in four bands (E24 series) for 5 % tolerance, or in five bands (E96 or E192 series).
Each color band appears as a single solid
line, voids are permissible if at least 2/3 of the band is visible from each radial angle of view. The
last color band for tolerance is approximately 50 % wider than the other bands.
•
ZCM207 Color code marking is applied according to IEC 60062 in four (E24 series) or six bands (E96 series). Each color band appears as a single
solid line, voids are permissible if at least
2/3 of the band is visible from each radial angle of view. The last color band represents the TCR for
resistors with TCR ≤50 ppm/K and nominal tolerance ≤1 %.
Zero ohm jumpers are marked with one centered black band.