GreenTech EC tubeaxial fans
Ø 119 x 38 mm
Material: Housing: GRP1) (PBT)
Impeller: GRP1) (PA)
Direction of air flow: Exhaust over struts
Direction of rotation: Clockwise,
looking towards rotor
Connection: with 2 flat pins 2.8 x 0.5
(not with IP65) optional
flying leads
Highlights: Fully integrated converter
and fan electronics. ACi4400
models are universally usable
for all main voltages between
90 and 264 VAC. Compact
design and lightweight.
Weight: 275 g
Possible special versions:
- Speed signal
- PWM speed control
- Analog speed control
- Moisture protection
- Salt spray protection
- Degree of protection: IP 65
- Compliance for use in systems with
flammable refrigerant charge up
to 150 g
(1) Fiberglass-reinforced plastic
Subject to change
Rotor protrusion max. 0.6 mm.
Nominal Data
Air flow
Air flow
Nominal voltage
Frequency
Voltage range
Sound pressure level
Sound power level
Sintec sleeve bearings
Ball bearings
Power consumption
Nominal speed
Temperature range
Service life L10 (40 °C)
ebm-papst standard
Service life L10 (Tmax)
ebm-papst standard
Life ecpectancy L10IPC
(40 °C)
Curve
Type m3/h cfm VAC Hz VAC dB(A) Bel(A) / Watts rpm-1 °CHours Hours
ACi4400HHAU* 175 103 100...240 50 / 60 90...264 43 5.5 4.5 3,300 -40...+75 65,000 / 25,000 110,000
ACi4400/2HHP** 175 103 100...240 50 / 60 90...264 43 5.5 4.5 3,300 -40...+75 65,000 / 25,000 110,000
ACi4420ML 100 59 230 50 / 60 195...265 25 4.1 1.7 1,850 -40...+75 65,000 / 25,000 110,000
ACi4420N 147 86 230 50 / 60 195...265 36 4.9 2.8 2,700 -40...+75 65,000 / 25,000 110,000
ACi4420H 160 94 230 50 / 60 195...265 39 5.1 3.2 3,000 -40...+75 65,000 / 25,000 110,000
ACi4420HH 175 103 230 50 / 60 195...265 43 5.5 4.4 3,300 -40...+75 65,000 / 25,000 110,000
ACi4410HH 175 103 115 50 / 60 85...132 43 5.5 4.4 3,300 -40...+75 65,000 / 25,000 110,000
ACi4400L 78 46 100...240 50 / 60 90...264 23 3.7 1.1 1,500 -40...+75 65,000 / 25,000 110,000
ACi4400MLR*** 100 59 100...240 50 / 60 90...264 25 4.1 1.7 1,850 -40...+75 65,000 / 25,000 110,000
ACi4400H 160 94 100...240 50 / 60 90...264 39 5.2 3.8 3,000 -40...+75 65,000 / 25,000 110,000
ACi4400HH 175 103 100...240 50 / 60 90...264 43 5.5 4.4 3,300 -40...+75 65,000 / 25,000 110,000
1
8
2
8
3
5
7
4
6
8
8
56 7 8
Air performance measured
according to: ISO 5801. Installation
category A, without contact
protection. Noise: Total sound
power level LWA ISO 10302
measured on a hemisphere with
a radius of 2 m. Sound pressure
level LpA measured at 1 m distance
from fan axis. The values given are
applicable only under the specified
measuring conditions and may
differ depending on the installation
conditions. In the event of deviation
from the standard configuration, the
parameters must be checked after
installation! For detailed information
see http://www.ebmpapst.com/
general conditions
* analog (5-10 VDC) speed control input, IP 65 ** PWM speed control input and 2ppr, open collector tach output *** moisture protection