www.lightechinc.com
LIGHT YEARS AHEAD
WWW.LIGHTECHINC.COM
TM
Standards/Approvals
VDE and VDE-EMV approved
Transformer meets CE standards
RoHS compliant
Available Version
901105240LB-Standard Version
Mechanical and Thermal
Dimensions(mm) 30 x 51 x 113.5
Weight 120 grams
Tc Max 85°C
Ta Max 45°C
PC plastic casing
Removable mounting ears
Output Voltage vs. Load at 240V
Output vs. Input at Max. Load
MM
Rev. 1
11.4
11.5
11.6
11.7
11.8
11.9
12
12.1
35W 105W
9.5
10
10.5
11
11.5
12
12.5
207V 230V 253V
Electrical
Maximum load 105W
Minimum load with dimmer 35W
Input 230-240V 50/60Hz
Output at Max. load 11.5V 35kHz
Input current at Max. load 9A
Output current at Max. load 9.5A
Power factor Min. 0.98
Dimmable
EMC (RFI) EN 55015
Harmonics EN 61000-3-2
Electrostatic Discharge IEC61000-4-2
EMC Immunity IEC61000-4-3
Burst IEC61000-4-4
Surge IEC61000-4-5
Injected RF IEC61000-4-6
Mains interruption IEC61000-4-11
Immunity EN 61547/61047
Safety EN 61347
SELV
- PENDING
10
LET-105-12V/240V R LB
Lite Beetle
See reverse side for more information
Short Circuit and Thermal
Protection
Electronic internal universal resettable
short circuit protection. Auto-Reset
thermal cut-off @ 100C.
12.2
12.3
12.4
Mounting Instructions
Safety Instructions:
1. Please note national installation
regulations.
2. The measurement of output
voltage can only be done with
suitable measuring instruments.
LET-105-12V/240V R LB
Lite Beetle
Electronic safety isolating