Speed and accuracy for test optimization
8-slot mainframe accepts up to 8 DC
power modules
1200 W total DC power output, up to 150 W
per module

Fast, low-noise outputs

Optional isolation and polarity reversal relays
Built-in measurements and advanced

Protection features to ensure DUT safety


66000A 1200 W DC
Modular Power System,GPIB

66000 modular power system
Keysight Technologies, Inc. 66000 modular power system simplifies
test-system assembly, cabling, programming, debugging and
operation. It is ideal for ATE and production test environments,
where it can supply bias power and stimulus to subassemblies and
final products. The modular power system saves rack space, the
7-inch-high (4-EIA units) mainframe can accommodate up to eight
DC power modules.
Key features
GPIB-programmable voltage and current
Programmable over-voltage and over-current protection
Self-test initiated at power-up or from GPIB command
Electronic calibration over GPIB or from keyboard
Over-temperature protection
Discrete fault indicator/remote inhibit (DFI/RI)
Five nonvolatile store-recall states per output
User-definable power-on state
Multiple mainframes at One GPIB address
The Keysight serial link feature will allow you to control up to
16 outputs at one GPIB address by connecting an auxiliary
mainframe. The serial link cable comes standard with the
66000 MPS mainframe. For applications with a broader range of
power requirements, one 66000 mainframe can be connected with
up to eight of the 6640, 6650, 6670, 6680, 6690 or 6030 series of
system power supplies. This solution provides power ranges from
150 watts to 5000 watts at one primary GPIB address.
Output connections
System assembly is simplified thanks to a quick-disconnect connector
assembly on each module. Once your wires are connected to the
load, the connector design permits the modules to be removed
from the front of the mainframe without disconnecting cabling or
removing the mainframe from the rack. One connector assembly is
shipped with each module.

Increase test throughput by using the output sequencing feature
of the 66000 MPS. This powerful feature allows you to download
up to 20 voltage, current, and dwell-time parameter sets per output.
This sequence can be paced by the programmed dwell times. As
an alternative, triggers can be used to step through the output
list. The output sequences can be executed without controller
intervention, thereby increasing overall test system throughput.


Supplemental Characteristics
(Non-warranted characteristics determined
by design and useful in applying the product)
66101A
66102A
66103A
66104A
66105A
66106A
Average programming resolution
Voltage
Current
Over voltage protection(OVP)
2.4 mV
4.6 mA
50 mV
5.9 mV
2.3 mA
120 mV
10.4 mV
1.4 mA
200 mV
18.0 mV
0.75 mA
375 mV
36.0 mV
0.39 mA
750 mV
60.0 mV
0.23 mA
1.25 mV
OVP accuracy 250 mV 500 mV 800 mV 1 V 1.5 V 2.5 V
Specifications
(at 0 ° to 55 °C unless otherwise specified)
66101A 66102A 66103A 66104A 66105A 66106A
Output ratings at 40°C
Output voltage
Output current
Maximum power
0 to 8 V
0 to 16 A
128 W
0 to 20 V
0 to 7.5 A
150 W
0 to 35 V
0 to 4.5 A
150 W
0 to 60 V
0 to 2.5 A
150 W
0 to 120 V
0 to 1.25 A
150 W
0 to 200 V
0 to 0.75 A
150 W
Programming accuracy (at 25 °C ± 5 °C)
Voltage 0.03% +
Current 0.03% +
3 mV
6 mA
8 mV
3 mA
13 mV
12 mA
27 mV
1.2 mA
54 mV
0.6 mA
90 mV
0.4 mA
Readback accuracy (via GPIB or keyboard dis-
play at 25 °C ± 5 °C)
Voltage 0.02% +
Current 0.02% +
2 mV
6 mA
5 mV
3 mA
8 mV
2 mA
16 mV
1 mA
32 mV
0.6 mA
54 mV
0.3 mA
Ripple and noise from 20 Hz to 20 MHz
Constant voltage rms
peak-to-peak
Constant current rms
2 mV
5 mV
8 mA
3 mV
7 mV
4 mA
5 mV
10 mV
2 mA
9 mV
15 mV
1 mA
18 mV
25 mV
1 mA
30 mV
50 mV
1 mA
Line regulation
Voltage
Current
0.5 mV
0.75 mA
0.5 mV
0.5 mA
1 mV
0.2 mA
2 mV
0.1 mA
3 mV
50 µA
5 mV
30 µA
Load regulation
Voltage
Current
1 mV
0.5 mA
1 mV
0.2 mA
1 mV
0.2 mA
2 mV
0.1 mA
4 mV
50 µA
7 mV
30 µA
Transient response time Less than 1 ms for the output voltage to recover within 100 mV of its previous level following any
step change in load current up to 10 percent of the power module rated output current

continued
Supplemental Characteristics
(Non-warranted characteristics determined
by design and useful in applying the product)
66101-J03
Special order
option
66101-J05
Special order
option
66101-J05
Special order
option
66103-J01
Special order
option
66103A-J02
Special order
option
Average programming resolution
Voltage
Current
OVP
2 mV
6 mA
45 mV
3,6 mV
4.6 mA
75 mV
4.5 mV
31 mA
90 mV
11 mV
1.4 mA
200 mV
12 mV
1.2 mA
230 mV
OVP accuracy 250 mV 375 mV 375 mV 850 mV 920 mV
Specifications
(at 0 ° to 55 °C unless otherwise specified)
66101-J03
Special order
option
66101-J05
Special order
option
66101-J05
Special order
option
66103-J01
Special order
option
66103A-J02
Special order
option
Output ratings at 40°C
Output voltage
Output current
Maximum power
5.7 V
20 A
114 W
12 V
12 A
144 W
15 V
10 A
150 W
37 V
4.5 A
167 W
40 V
3.6 A
144 W
Programming accuracy (at 25 °C ± 5 °C)
Voltage 0.03% +
Current 0.03% +
2.5 mV
8 mA
5 mV
6 mA
8 mV
4 mA
13 mV
2 mA
15 mV
2 mA
Readback accuracy (via GPIB or keyboard
display at 25 °C ± 5 °C)
Voltage 0.02% +
Current 0.02% +
2 mV
8 mA
3 mV
6 mA
5 mV
4 mA
8 mV
2 mA
9.2 mV
2 mA
Ripple and noise from 20 Hz to 20 MHz
Voltage rms
peak-to-peak
Current rms
2 mV
5 mV
10 mA
3 mV
7 mV
8 mA
3 mV
7 mV
6 mA
5.3 mV
10.6 mV
2 mA
6 mV
11.5 mV
2 mA
Line regulation
Voltage
Current
0.5 mV
0.5 mA
0.5 mV
0.75 mA
0.5 mV
0.5 mA
1 mV
0.3 mA
1 mV
0.3 mA
Load regulation
Voltage
Current
1 mV
1 mA
1 mV
0.5 mA
1 mV
0.3 mA
1 mV
0.2 mA
1 mV
0.2 mA
Transient response time Less than 1 ms for the output voltage to recover within 100 mV of its previous level following any
step change in load current up to 10 percent of the power module rated output current

continued
Supplemental Characteristics
(Non-warranted characteristics determined
by design and useful in applying the product)
66103A-J09
Special order
option
66103A-J12
Special order
option
66104A-J09
Special order
option
66105A-J01
Special order
option
Average programming resolution
Voltage
Current
OVP
10.4 mV
2 mA
200 mV
8 mV
2 mA
150 mV
16.5 mV
0.9 mA
350 mV
2 mV
1.2 mA
230 mV
Output accuracy 800 mV 600 mV 950 mV 920 mV
Specifications
(at 0 ° to 55 °C unless otherwise specified)
66103A-J09
Special order
option
66103A-J12
Special order
option
66104A-J09
Special order
option
66105A-J01
Special order
option
Output ratings at 40°C
Output voltage
Output current
Maximum power
28.5 V
5.5 A
157 W
24 V
6 A
144 W
55 V
3 A
165 W
35 V
1.25 A
44 W
Programming accuracy at 25 °C ± 5 °C
Voltage 0.03% +
Current 0.03% +
13 mV
3 mA
13 mV
3 mA
25 mV
1.5 mA
15 mV
11 mA
Readback accuracy (via GPIB or keyboard
display at 25 °C ± 5 °C)
Voltage 0.02% +
Current 0.02% +
8 mV
3 mA
8 mV
3 mA
15 mV
1.2 mA
9 mV
0.6 mA
Ripple and noise from 20 Hz to 20 MHz
Constant voltage rms
peak-to-peak
Constant current rms
5 mV
10 mV
4 mA
5 mV
10 mV
4 mA
9 mV
15 mV
1.2 mA
6 mV
11.5 mV
1 mA
Line regulation
Voltage
Current
1 mV
0.3 mA
1 mV
0.3 mA
2 mV
0.1 mA
1 mV
50 µA
Load regulation
Voltage
Current
1 mV
0.2 mA
1 mV
0.2 mA
2 mV
0.1 mA
1 mV
50 µA
Transient response time Less than 1 ms for the output voltage to recover within 100 mV of its previous level following
any step change in load current up to 10 percent of the power module rated output current

Keysight Models: 66000A


DC floating voltage: Output terminals can be floated up to ± 240
VDC from chassis ground
Remote sensing: Up to half the rated output voltage can be
dropped across each load lead. Add 2 mV to the voltage load
regulation specification for each 1 V change in the negative
output lead caused by a load current change.
Command processing time: The average time for the output
voltage to change after getting an GPIB command is 20 ms.
Output programming response time (with full resistive load):
The rise and fall time (10% to 90% and 90% to 10%) of the
output voltage is less than 20 ms. The output voltage change
settles within 0.1% of the final value in less than 120 ms.
Down programming: An active down programmer sinks
approximately 10% of the rated output current
Calibration interval: One year
AC input of system mainframe:
Voltage 100 VAC 120 VAC 200 VAC 220 VAC 230 VAC 240 VAC
Max.
current
29 A 25 A 16 A 16 A 15 A 15 A
Input power of system mainframe: 3200 VA (max.), 1800 W (max.),
1600 W (typ.)
GPIB interface capabilities: SH1, AH1, TE6, LE4, SR1, RL1, PP0, DC1,
DT1, E1, and C0, and a command set compatible with IEEE-488.2
and SCPI
Software driver: VXIplug&play
Regulatory compliance: Listed to UL 1244; certified to CSA 22.2
No. 231; conforms to IEC 61010-1
Size: 66000A: 425.7 mm W x 192 mm H x 677.93 mm D
(16.76 in x 7.28 in x 26.69 in), including feet and rear connectors
Weight: Net, 66000A, 15 kg (33 lb); 66001A, 1.05 kg (2.3 lb);
66101-66106A, 2.8 kg (6 lb). Shipping, 66000A, 19 kg (42 lb);
66001A, 1.34 kg (2.95 lb); 66101–66106A, 4.1 kg (9 lb)
Warranty: One year
Top
Front
677.9 mm
26.69"
104.9 mm
4.13"
425.7 mm
16.76"
177.3 mm
6.98"
190 mm
7.5"


66000A MPS mainframe
The 66000A comes with full documentation on
CD-ROM. The CD-ROM includes user’s guide,
installation guide, programming guide, service manual,
quick start guide, and application notes.
Opt 0L1 Printed programming and installation guides.
Opt 0B3 Printed service manual
Opt 831 Power cord, no plug, Americas
Opt 833 Power cord, no plug, Europe
Opt 834 Power cord, no plug, USA
Opt 841 Power cord, Americas, Japan, NEMA 6-20P,
20 A, 250 V plug
Opt 845 Power cord, Scandinavia,
IEC 309, 16 A, 220 V plug
Opt 846 Power cord, North America, NEMA L5-30P,
30 A, 120 V plug
Opt 847 Power cord, Europe, CEE 7/7, 16 A,
220 V plug
Opt 848 Power cord, S. Africa, India, BS 546,
15 A, 240 V
Module options
Each module comes with full documentation
on CD-ROM
Opt 760 Adds isolation/polarity relays
Opt J17 External monitor
Opt 0L1 Printed installation sheet and user’s guide
Opt 0B3 Printed service manual
Accessories
1CM023A* Rack mount flange kit 177.0 mm H (4U)
two flange brackets
1CP013A* Rack mount flange and handle kit 177.0 mm
H (4U) – two brackets and front handles
E3663AC Support rails for Keysight rack cabinets
66001A MPS keyboard includes 2 m (6 ft) cables
66002A Rack kit for 66001A keyboard
p/n 5060-3351 Field-installable relay kit
p/n 5060-3386 Standard connector assembly
p/n 5060-3387 Standard connector assembly with
installed relays (Option 760)
Application notes
66000 Modular Power System Product Note,
5988-2800EN
10 Practical Tips You Need to Know About Your Power
Products, 5965-8239E
10 Hints for Using Your Power Supply to Decrease Test
Time, 5968-6359E
Keysight DC Power Supplies for Base Station Testing,
5988-2386EN
*Support rails required

myKeysight
www.keysight.com/find/mykeysight

Keysight Assurance Plans
www.keysight.com/find/AssurancePlans



www.keysight.com/quality

DEKRA Certified ISO 9001:2008

Keysight Channel Partners
www.keysight.com/find/channelpartners





5990-9310EN






Americas
Canada (877) 894 4414
Brazil 55 11 3351 7010
 001 800 254 2440
United States (800) 829 4444

Australia 1 800 629 485
 800 810 0189
 800 938 693
India 1 800 112 929
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
 1 800 375 8100
Taiwan 0800 047 866
 (65) 6375 8100
Europe & Middle East
Austria 0800 001122
 0800 58580
Finland 0800 523252
France 0805 980333
Germany 0800 6270999
Ireland 1800 832700
Israel 1 809 343051
Italy 800 599100
 +32 800 58580
 0800 0233200
Russia 8800 5009286
Spain 0800 000154
Sweden 0200 882255
Switzerland 0800 805353



 0800 0260637


(BP-07-10-14)
