CY29FCT818T DIAGNOSTIC SCAN REGISTER WITH 3-STATE OUTPUTS SCCS012B - MAY 1994 - REVISED NOVEMBER 2001 D D D D D D D D D D D D, P, Q, OR SO PACKAGE (TOP VIEW) Function, Pinout, and Drive Compatible With FCT, F Logic, and AM29818 Reduced VOH (Typically = 3.3 V) Version of Equivalent FCT Functions Edge-Rate Control Circuitry for Significantly Improved Noise Characteristics Ioff Supports Partial-Power-Down Mode Operation Matched Rise and Fall Times Fully Compatible With TTL Input and Output Logic Levels 8-Bit Pipeline and Shadow Register ESD Protection Exceeds JESD 22 - 2000-V Human-Body Model (A114-A) - 200-V Machine Model (A115-A) - 1000-V Charged-Device Model (C101) CY29FCT818CT - 64-mA Output Sink Current - 32-mA Output Source Current CY29FCT818ATDMB - 20-mA Output Sink Current - 3-mA Output Source Current 3-State Outputs OE DCLK D0 D1 D2 D3 D4 D5 D6 D7 SDI GND 1 24 2 23 3 22 4 21 5 20 6 19 7 18 8 17 9 16 10 15 11 14 12 13 VCC MODE Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 SDO PCLK description The CY29FCT818T contains a high-speed 8-bit general-purpose data pipeline register and a high-speed 8-bit shadow register. The general-purpose register can be used in an 8-bit-wide data path for a normal system application. The shadow register is designed for applications such as diagnostics in sequential circuits, where it is desirable to load known data at a specific location in the circuit and to read the data at that location. The shadow register can load data from the output of the device, and can be used as a right-shift register with bit-serial input (SDI) and output (SDO), using DCLK. The data register input is multiplexed to enable loading from the shadow register or from the data input pins, using PCLK. Data can be loaded simultaneously from the shadow register to the pipeline register, and from the pipeline register to the shadow register, provided setup-time and hold-time requirements are satisfied, with respect to the two independent clock inputs. In a typical application, the general-purpose register in this device replaces an 8-bit data register in the normal data path of a system. The shadow register is placed in an auxiliary bit-serial loop that is used for diagnostics. During diagnostic operation, data is shifted serially into the shadow register, then transferred to the general-purpose register to load a known value into the data path. To read the contents at that point in the data path, the data is transferred from the data register into the shadow register, then shifted serially in the auxiliary diagnostic loop to make it accessible to the diagnostics controller. This data then is compared with the expected value to diagnose faulty operation of the sequential circuit. This device is fully specified for partial-power-down applications using Ioff. The Ioff circuitry disables the outputs, preventing damaging current backflow through the device when it is powered down. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Copyright 2001, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. On products compliant to MIL-PRF-38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 1 CY29FCT818T DIAGNOSTIC SCAN REGISTER WITH 3-STATE OUTPUTS SCCS012B - MAY 1994 - REVISED NOVEMBER 2001 ORDERING INFORMATION SPEED (ns) PACKAGE TA -40C 40C to 85C ORDERABLE PART NUMBER TOP-SIDE MARKING DIP - P Tube 6 CY29FCT818CTPC CY29FCT818CTPC QSOP - Q Tape and reel 6 CY29FCT818CTQCT 29FCT818C Tube 6 CY29FCT818CTSOC Tape and reel 6 CY29FCT818CTSOCT SOIC - SO 29FCT818C -55C to 125C CDIP - D Tube 12 CY29FCT818ATDMB Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at www.ti.com/sc/package. FUNCTION TABLE INPUTS MODE SDI DCLK PCLK OUTPUT SDO SHADOW REGISTER PIPELINE REGISTER L X X S7 S0SDI SiSi-1 NA L X X H L X S7 L H H X H NA SiYi Hold PiDi NA NA OPERATION Serial shift; D7-D0 output disabled Load pipeline register from data input Load shadow register from Y output Hold shadow register; D7-D0 output enabled H X X SDI NA PiSi Load pipeline register from shadow register H = High logic level, L = Low logic level, X = Don't care, Low-to-high transition, = Transfer direction, NA = Not applicable 2 POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 CY29FCT818T DIAGNOSTIC SCAN REGISTER WITH 3-STATE OUTPUTS SCCS012B - MAY 1994 - REVISED NOVEMBER 2001 logic diagram SDI DCLK D0-D7 11 8-Bit Shadow Register 2 14 SD0 CLK S0-S7 8 D MODE Q 23 MUX 8 PCLK 8-Bit Pipeline Register 13 8 OE P0-P7 1 8 Y0-Y7 absolute maximum rating over operating free-air temperature range (unless otherwise noted) Supply voltage range to ground potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5 V to 7 V DC input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5 V to 7 V DC output voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5 V to 7 V DC output current (maximum sink current/pin) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 mA Package thermal impedance, qJA (see Note 1): P package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67C/W (see Note 2): Q package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61C/W (see Note 2): SO package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46C/W Ambient temperature range with power applied, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65C to 135C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65C to 150_C Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The package thermal impedance is calculated in accordance with JESD 51-3. 2. The package thermal impedance is calculated in accordance with JESD 51-7. POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 3 CY29FCT818T DIAGNOSTIC SCAN REGISTER WITH 3-STATE OUTPUTS SCCS012B - MAY 1994 - REVISED NOVEMBER 2001 recommended operating conditions (see Note 3) CY29FCT818ATDMB CY29FCT818T MIN NOM MAX MIN NOM MAX 4.5 5 5.5 4.75 5 5.25 UNIT VCC VIH Supply voltage VIL IOH Low-level input voltage 0.8 0.8 V High-level output current -3 -32 mA IOL TA Low-level output current 20 64 mA 85 C High-level input voltage 2 Operating free-air temperature 2 -55 125 V V -40 NOTE 3: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) TEST CONDITIONS CY29FCT818ATDMB MIN TYP MAX VCC = 4.5 V, IIN = -18 mA -0.7 VCC = 4.75 V, IIN = -18 mA VCC = 4.5 V, IOH = -3 mA PARAMETER VIK VOH VOL Vhys VCC = 4 4.75 75 V 2.4 2 IOH = -15 mA 2.4 VCC = 4.5 V, IOL = 20 mA VCC = 4.75 V, IOL = 64 mA 0.3 VIN = VCC VCC = 5.5 V, VIN = 2.7 V VCC = 5.25 V, VIN = 2.7 V VCC = 5.5 V, VIN = 0.5 V VCC = 5.25 V, VIN = 0.5 V VCC = 5.5 V, VOUT = 2.7 V VCC = 5.25 V, VOUT = 2.7 V VCC = 5.5 V, VOUT = 0.5 V VCC = 5.25 V, VCC = 5.5 V, VOUT = 0.5 V VOUT = 0 V VCC = 5.25 V, VOUT = 0 V Ioff VCC = 0 V, VOUT = 4.5 V ICC VCC = 5.5 V, VCC = 5.25 V, VIN 0.2 V, VIN 0.2 V, ICC VCC = 5.5 V, VIN = 3.4 V, f1 = 0, Outputs open VCC = 5.25 V, VIN = 3.4 V, f1 = 0, Outputs open IIL IOZH IOZL IOS V 0.55 0.2 VIN = VCC 0.55 0.2 5 1 1 1 1 10 10 -10 -10 -120 -225 -60 -120 1 VIN VCC - 0.2 V VIN VCC - 0.2 V 0.2 0.5 V V 5 -60 V 3.3 0.3 All inputs -1.2 UNIT 3.3 IOH = -32 mA VCC = 5.25 V, IIH -1.2 -0.7 VCC = 5.5 V, II CY29FCT818T TYP MAX MIN -225 1 1.5 0.2 1.5 0.5 2 2 A A A A A mA A mA mA Typical values are at VCC = 5 V, TA = 25C. Not more than one output should be shorted at a time. Duration of short should not exceed one second. The use of high-speed test apparatus and/or sample-and-hold techniques are preferable to minimize internal chip heating and more accurately reflect operational values. Otherwise, prolonged shorting of a high output can raise the chip temperature well above normal and cause invalid readings in other parametric tests. In any sequence of parameter tests, IOS tests should be performed last. Per TTL-driven input (VIN = 3.4 V); all other inputs at VCC or GND 4 POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 CY29FCT818T DIAGNOSTIC SCAN REGISTER WITH 3-STATE OUTPUTS SCCS012B - MAY 1994 - REVISED NOVEMBER 2001 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) (continued) PARAMETER ICCD CY29FCT818ATDMB MIN TYP MAX TEST CONDITIONS VCC = 5.5 V, Outputs open, One input switching at 50% duty cycle, OE = GND, VIN 0.2 V or VIN VCC - 0.2 V CY29FCT818T TYP MAX MIN 0.25 VCC = 5.25 V, Outputs open, One input switching at 50% duty cycle, OE = GND, VIN 0.2 V or VIN VCC - 0.2 V VCC = 5.5 V, Out uts o en, Outputs open f0 = 10 MHz, OE = GND IC# VCC = 5.25 V, Out uts o en, Outputs open f0 = 10 MHz, OE = GND One bit switching at f1 = 5 MHz at 50% duty cycle Eight bits and four controls switching at f1 = 5 MHz at 50% duty cycle One bit switching at f1 = 5 MHz at 50% duty cycle Eight bits and four controls switching at f1 = 5 MHz at 50% duty cycle 0.25 VIN 0.2 V or VIN VCC - 0.2 V 5.3 VIN = 3.4 V or GND 7.3 VIN 0.2 V or VIN VCC - 0.2 V 17.8|| VIN = 3.4 V or GND 30.8|| UNIT mA/ MHz mA VIN 0.2 V or VIN VCC - 0.2 V 5.3 VIN = 3.4 V or GND 7.3 VIN 0.2 V or VIN VCC - 0.2 V 17.8|| VIN = 3.4 V or GND 30.8|| Ci 5 10 5 10 pF Co 9 12 9 12 pF Typical values are at VCC = 5 V, TA = 25C. This parameter is derived for use in total power-supply calculations. # IC = ICC + ICC x DH x NT + ICCD (f0/2 + f1 x N1) Where: IC = Total supply current ICC = Power-supply current with CMOS input levels ICC = Power-supply current for a TTL high input (VIN = 3.4 V) DH = Duty cycle for TTL inputs high NT = Number of TTL inputs at DH ICCD = Dynamic current caused by an input transition pair (HLH or LHL) f0 = Clock frequency for registered devices, otherwise zero f1 = Input signal frequency N1 = Number of inputs changing at f1 All currents are in milliamperes and all frequencies are in megahertz. || Values for these conditions are examples of the ICC formula. POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 5 CY29FCT818T DIAGNOSTIC SCAN REGISTER WITH 3-STATE OUTPUTS SCCS012B - MAY 1994 - REVISED NOVEMBER 2001 timing requirements over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1) CY29FCT818AT PARAMETER tw Pulse width MIN 15 5 25 5 6 2 15 3.5 5 2 MODE before DCLK 12 3.5 SDI before DCLK 10 3.5 DCLK before PCLK 15 3.5 PCLK before DCLK Y before DCLK th Hold time MIN DCLK high and low MODE before PCLK Setup time CY29FCT818CT PCLK high and low D before PCLK tsu MAX 45 8.5 D after PCLK 2 1.5 MODE after PCLK 0 0 Y after DCLK 5 1.5 MODE after DCLK 5 1.5 SDI after DCLK 0 0 MAX UNIT ns ns ns switching characteristics over operating free-air temperature range (see Figure 1) PARAMETER tpd d tPZL tPZH tPLZ tPHZ 6 FROM (INPUT) TO (OUTPUT) CY29FCT818AT MIN MAX CY29FCT818CT MIN MAX PCLK Y 12 6 MODE SDO 18 7.2 SDI SDO 18 7.1 DCLK SDO 30 7.2 OE Y 20 8 DCLK D 35 9 OE Y 20 8.5 DCLK D 30 9 OE Y 20 5.5 DCLK D 45 5.5 OE Y 30 8 DCLK D 90 8 POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 UNIT ns ns ns ns ns CY29FCT818T DIAGNOSTIC SCAN REGISTER WITH 3-STATE OUTPUTS SCCS012B - MAY 1994 - REVISED NOVEMBER 2001 PARAMETER MEASUREMENT INFORMATION 7V From Output Under Test From Output Under Test Test Point CL = 50 pF (see Note A) Open TEST GND CL = 50 pF (see Note A) 500 S1 500 S1 Open 7V Open tPLH/tPHL tPLZ/tPZL tPHZ/tPZH 500 LOAD CIRCUIT FOR 3-STATE OUTPUTS LOAD CIRCUIT FOR TOTEM-POLE OUTPUTS 3V 1.5 V Timing Input 0V tw tsu 3V 1.5 V Input 1.5 V th 3V 1.5 V Data Input 1.5 V 0V 0V VOLTAGE WAVEFORMS PULSE DURATION VOLTAGE WAVEFORMS SETUP AND HOLD TIMES 3V 1.5 V Input 1.5 V 0V tPLH tPHL 1.5 V 1.5 V VOL tPHL Out-of-Phase Output tPLZ 3.5 V 1.5 V tPZH VOH 1.5 V VOL VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES INVERTING AND NONINVERTING OUTPUTS 1.5 V 0V Output Waveform 1 (see Note B) tPLH 1.5 V 1.5 V tPZL VOH In-Phase Output 3V Output Control Output Waveform 2 (see Note B) VOL + 0.3 V VOL tPHZ 1.5 V VOH - 0.3 V VOH 0 V VOLTAGE WAVEFORMS ENABLE AND DISABLE TIMES LOW- AND HIGH-LEVEL ENABLING NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. The outputs are measured one at a time with one input transition per measurement. Figure 1. Load Circuit and Voltage Waveforms POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 7 PACKAGE OPTION ADDENDUM www.ti.com 25-Sep-2013 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan Lead/Ball Finish (2) MSL Peak Temp Op Temp (C) Device Marking (3) (4/5) 5962-9682701Q3A ACTIVE LCCC FK 28 1 TBD POST-PLATE N / A for Pkg Type -55 to 125 59629682701Q3A 5962-9682701QLA ACTIVE CDIP JT 24 1 TBD A42 N / A for Pkg Type -55 to 125 5962-9682701QL A CY29FCT818ATDM B CY29FCT818ATDMB ACTIVE CDIP JT 24 1 TBD A42 N / A for Pkg Type -55 to 125 5962-9682701QL A CY29FCT818ATDM B CY29FCT818CTSOCT ACTIVE SOIC DW 24 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM -40 to 85 29FCT818C CY29FCT818CTSOCTE4 ACTIVE SOIC DW 24 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM -40 to 85 29FCT818C CY29FCT818CTSOCTG4 ACTIVE SOIC DW 24 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM -40 to 85 29FCT818C (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. (4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device. Addendum-Page 1 Samples PACKAGE OPTION ADDENDUM www.ti.com 25-Sep-2013 (5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 2 PACKAGE MATERIALS INFORMATION www.ti.com 14-Jul-2012 TAPE AND REEL INFORMATION *All dimensions are nominal Device CY29FCT818CTSOCT Package Package Pins Type Drawing SOIC DW 24 SPQ Reel Reel A0 Diameter Width (mm) (mm) W1 (mm) 2000 330.0 24.4 Pack Materials-Page 1 10.75 B0 (mm) K0 (mm) P1 (mm) W Pin1 (mm) Quadrant 15.7 2.7 12.0 24.0 Q1 PACKAGE MATERIALS INFORMATION www.ti.com 14-Jul-2012 *All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) CY29FCT818CTSOCT SOIC DW 24 2000 367.0 367.0 45.0 Pack Materials-Page 2 MECHANICAL DATA MCER004A - JANUARY 1995 - REVISED JANUARY 1997 JT (R-GDIP-T**) CERAMIC DUAL-IN-LINE 24 LEADS SHOWN PINS ** A 13 24 B 1 24 28 A MAX 1.280 (32,51) 1.460 (37,08) A MIN 1.240 (31,50) 1.440 (36,58) B MAX 0.300 (7,62) 0.291 (7,39) B MIN 0.245 (6,22) 0.285 (7,24) DIM 12 0.070 (1,78) 0.030 (0,76) 0.100 (2,54) MAX 0.320 (8,13) 0.290 (7,37) 0.015 (0,38) MIN 0.200 (5,08) MAX Seating Plane 0.130 (3,30) MIN 0.023 (0,58) 0.015 (0,38) 0-15 0.014 (0,36) 0.008 (0,20) 0.100 (2,54) 4040110/C 08/96 NOTES: A. B. C. D. E. All linear dimensions are in inches (millimeters). This drawing is subject to change without notice. This package can be hermetically sealed with a ceramic lid using glass frit. Index point is provided on cap for terminal identification. Falls within MIL STD 1835 GDIP3-T24, GDIP4-T28, and JEDEC MO-058 AA, MO-058 AB POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All semiconductor products (also referred to herein as "components") are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI's terms and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily performed. TI assumes no liability for applications assistance or the design of Buyers' products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers' products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components in safety-critical applications. In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI's goal is to help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and requirements. Nonetheless, such components are subject to these terms. No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties have executed a special agreement specifically governing such use. Only those TI components which TI has specifically designated as military grade or "enhanced plastic" are designed and intended for use in military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of non-designated products, TI will not be responsible for any failure to meet ISO/TS16949. Products Applications Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers DLP(R) Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps DSP dsp.ti.com Energy and Lighting www.ti.com/energy Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial Interface interface.ti.com Medical www.ti.com/medical Logic logic.ti.com Security www.ti.com/security Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID www.ti-rfid.com OMAP Applications Processors www.ti.com/omap TI E2E Community e2e.ti.com Wireless Connectivity www.ti.com/wirelessconnectivity Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright (c) 2013, Texas Instruments Incorporated