Solid State Contactors for Heaters G3PE-Three-phase CSM_G3PE-Three-phase_DS_E_4_1 Compact, Slim-profile SSRs with Heat Sinks. Solid State Contactors for Three-phase Heaters Reduced Installation Work with DIN Track Mounting. * RoHS compliant. * Surge pass protection improved surge dielectric strength for output currents. (OMRON testing) * Slim design with 3-phase output and built-in heat sinks. * DIN Track mounting types and screw mounting types are available. All DIN Track mounting types mount to DIN Track (applicable DIN Track: TR35-15Fe (IEC 60715)). * Conforms to UL, CSA, and EN standards (TUV certification). Refer to Safety Precautions for All G3PE Models. Ordering Information List of Models Models with Built-in Heat Sinks Number of phases Insulation method Operation indicator Rated input voltage Zero cross function Type Applicable load *1 15 A, 100 to 240 VAC 25 A, 100 to 240 VAC 35 A, 100 to 240 VAC 45 A, 100 to 240 VAC DIN track mounting *2 15 A, 200 to 480 VAC 25 A, 200 to 480 VAC 35 A, 200 to 480 VAC 45 A, 200 to 480 VAC Three-phase Phototriac coupler Yes (yellow) 12 to 24 VDC Yes 15 A, 100 to 240 VAC 25 A, 100 to 240 VAC 35 A, 100 to 240 VAC 45 A, 100 to 240 VAC Screw mounting 15 A, 200 to 480 VAC 25 A, 200 to 480 VAC 35 A, 200 to 480 VAC 45 A, 200 to 480 VAC Number of poles Model 3 G3PE-215B-3N DC12-24 2 G3PE-215B-2N DC12-24 3 G3PE-225B-3N DC12-24 2 G3PE-225B-2N DC12-24 3 G3PE-235B-3N DC12-24 2 G3PE-235B-2N DC12-24 3 G3PE-245B-3N DC12-24 2 G3PE-245B-2N DC12-24 3 G3PE-515B-3N DC12-24 2 G3PE-515B-2N DC12-24 3 G3PE-525B-3N DC12-24 2 G3PE-525B-2N DC12-24 3 G3PE-535B-3N DC12-24 2 G3PE-535B-2N DC12-24 3 G3PE-545B-3N DC12-24 2 G3PE-545B-2N DC12-24 3 G3PE-215B-3 DC12-24 2 G3PE-215B-2 DC12-24 *3 3 G3PE-225B-3 DC12-24 2 G3PE-225B-2 DC12-24 3 G3PE-235B-3 DC12-24 2 G3PE-235B-2 DC12-24 3 G3PE-245B-3 DC12-24 2 G3PE-245B-2 DC12-24 3 G3PE-515B-3 DC12-24 2 G3PE-515B-2 DC12-24 *3 3 G3PE-525B-3 DC12-24 2 G3PE-525B-2 DC12-24 3 G3PE-535B-3 DC12-24 2 G3PE-535B-2 DC12-24 3 G3PE-545B-3 DC12-24 2 G3PE-545B-2 DC12-24 *1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5. *2. The applicable DIN Track is the TR35-15Fe (IEC 60715). For details, refer to the mounting information in the Safety Precautions for All G3PE Models. *3. DIN Track or Screw mounting. 1 G3PE-Three-phase Models with Externally Attached Heat Sinks Number of phases Insulation method Operation indicator Rated input voltage Zero cross function Type Applicable load * 15 A, 100 to 240 VAC 25 A, 100 to 240 VAC 35 A, 100 to 240 VAC Three-phase Phototriac coupler Yes (yellow) 12 to 24 VDC Yes Externally attached heat sinks 45 A, 100 to 240 VAC 15 A, 200 to 480 VAC 25 A, 200 to 480 VAC 35 A, 200 to 480 VAC 45 A, 200 to 480 VAC Number of poles Model 3 G3PE-215B-3H DC12-24 2 G3PE-215B-2H DC12-24 3 G3PE-225B-3H DC12-24 2 G3PE-225B-2H DC12-24 3 G3PE-235B-3H DC12-24 2 G3PE-235B-2H DC12-24 3 G3PE-245B-3H DC12-24 2 G3PE-245B-2H DC12-24 3 G3PE-515B-3H DC12-24 2 G3PE-515B-2H DC12-24 3 G3PE-525B-3H DC12-24 2 G3PE-525B-2H DC12-24 3 G3PE-535B-3H DC12-24 2 G3PE-535B-2H DC12-24 3 G3PE-545B-3H DC12-24 2 G3PE-545B-2H DC12-24 * The rated load current depends on the heat sink or radiator that is mounted. It also depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature. Accessories (Order Separately) Heat Sink Heat resistance Rth (s-a) (C/W) Model 1.67 Y92B-P50 1.01 Y92B-P100 0.63 Y92B-P150 0.43 Y92B-P200 0.36 Y92B-P250 2 G3PE-Three-phase Specifications Certification UL508, CSA22.2 No.14, and EN60947-4-3 Ratings (at an Ambient Temperature of 25C) Operating Circuit (All Models) ItemModel Same for all models Rated operating voltage 12 to 24 VDC Operating voltage range 9.6 to 30 VDC Rated input current (impedance) 10 mA max. (24 VDC) Must-operate voltage 9.6 VDC max. Must-release voltage 1 VDC min. Insulation method Phototriac Operation indicator Yellow LED Main Circuit of Models with Built-in Heat Sinks Item Model G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE215B- 215B- 225B- 225B- 235B- 235B- 245B- 245B- 515B- 515B- 525B- 525B- 535B- 535B- 545B- 545B3(N) 2(N) 3(N) 2(N) 3(N) 2(N) 3(N) 2(N) 3(N) 2(N) 3(N) 2(N) 3(N) 2(N) 3(N) 2(N) Rated load voltage Operating voltage range Rated load current *1 15 A (at 40C) Minimum load current Inrush current resistance (peak value) 100 to 240 VAC 200 to 480 VAC 75 to 264 VAC 180 to 528 VAC 25 A (at 40C) 35 A (at 25C) Applicable load (resistive load: AC1 class) *2 15 A (at 40C) 25 A (at 40C) 35 A (at 25C) 45 A (at 25C) 0.5 A 150 A 220 A (60 Hz, 1 cycle) (60 Hz, 1 cycle) Permissible I2t (reference value) 45 A (at 25C) 0.2 A 121A2s 260A2s 5.1 kW (at 200 VAC) 8.6 kW (at 200 VAC) 440 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) 1,260A2s 260A2s 1,260A2s 12.1 kW (at 200 VAC) 15.5 kW (at 200 VAC) 12.5 kW (at 480 VAC) 20.7 kW (at 480 VAC) 29.0 kW (at 480 VAC) 37.4 kW (at 480 VAC) *1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5. *2. Applicable Load Use the following formula to calculate the maximum total capacity of a heater load for a three-phase balanced load with delta connections. Maximum load capacity = Load current x Load voltage x 3 Example: 15 A x 200 V x 3 = 5,196 W 5.1 kW Example: 15 A x 400 V x 3 = 10,392 W 10.3 kW Main Circuit of Models with Externally Attached Heat Sinks Item Model G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE215B- 215B- 225B- 225B- 235B- 235B- 245B- 245B- 515B- 515B- 525B- 525B- 535B- 535B- 545B- 545B3H 2H 3HH 2H 3H 2H 3H 2H 3H 2H 3H 2H 3H 2H 3H 2H Rated load voltage Operating voltage range Rated load current * 15 A (at 40C) Minimum load current Inrush current resistance (peak value) Permissible I2t (reference value) Applicable load (resistive load: AC1 class) 100 to 240 VAC 200 to 480 VAC 75 to 264 VAC 180 to 528 VAC 25 A (at 40C) 35 A (at 25C) 45 A (at 25C) 0.2 A 25 A (at 40C) 35 A (at 25C) 45 A (at 25C) 0.5 A 150 A 220 A (60 Hz, 1 cycle) (60 Hz, 1 cycle) 121A2s 15 A (at 40C) 260A2s 440 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) 1,260A2s 260A2s 1,260A2s Refer to Engineering Data on page 5. * The rated load current depends on the heat sink or radiator that is mounted. It also depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5. 3 G3PE-Three-phase Characteristics Models with Built-in Heat Sinks Item Model G3PE215B3(N) G3PE215B2(N) G3PE225B3(N) Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. 1.8 V (RMS) max. Leakage current * 10 mA max. (at 200 VAC) 20 mA max. (at 480 VAC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance * DIN Track mounting: 10 to 55 to 10 Hz, 0.175-mm single amplitude (0.35-mm double amplitude) * Screw mounting: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) Shock resistance 294 m/s2 (reverse mounting: 98 m/s2) Ambient storage temperature -30 to 100C (with no icing or condensation) Ambient operating temperature -30 to 80C (with no icing or condensation) Ambient operating humidity 45% to 85% Weight Approx. 1.25 kg Approx. 1.45 kg G3PE225B2(N) G3PE235B3(N) Approx. 1.25 kg Approx. 1.65 kg G3PE235B2(N) Approx. 1.45 kg G3PE245B3(N) Approx. 2.0 kg G3PE245B2(N) Approx. 1.65 kg G3PE515B3(N) G3PE515B2(N) Approx. 1.25 kg G3PE525B3(N) Approx. 1.45 kg G3PE525B2(N) G3PE535B3(N) G3PE535B2(N) G3PE545B3(N) G3PE545B2(N) Approx. 1.25 kg Approx. 1.65 kg Approx. 1.45 kg Approx. 2.0 kg Approx. 1.65 kg G3PE525B2H G3PE535B3H G3PE535B2H G3PE545B3H G3PE545B2H * The leakage current of phase S will be approximately 3 times larger if the 2-element model is used. Models with Externally Attached Heat Sinks Item Model G3PE215B3H G3PE215B2H G3PE225B3H G3PE225B2H G3PE235B3H G3PE235B2H G3PE245B3H G3PE245B2H G3PE515B3H G3PE515B2H G3PE525B3H Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. 1.8 V (RMS) max. Leakage current * 10 mA max. (at 200 VAC) 20 mA max. (at 480 VAC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) Shock resistance Destruction: 294 m/s2 Ambient storage temperature -30 to 100C (with no icing or condensation) Ambient operating temperature -30 to 80C (with no icing or condensation) Ambient operating humidity 45% to 85% Weight Approx. 300 g * The leakage current of phase S will be approximately 3 times larger if the 2-element model is used. Heat Sinks Model Weight Y92B-P50 Approx. 450 g Y92B-P100 Approx. 450 g Y92B-P150 Approx. 600 g Y92B-P200 Approx. 850 g Y92B-P250 Approx. 1,200 g 4 G3PE-Three-phase Engineering Data Input Voltage vs. Input Impedance and Input Voltage vs. Input Current G3PE-5@@B-@@ 10 Input impedance (k) Input current (mA) Input impedance (k) Input current (mA) G3PE-2@@B-@@ 9 8 7 6 15 Ta = 25C 14 13 12 11 10 9 Input current 8 5 Input current 7 6 4 5 3 Input impedance 4 Input impedance 2 3 2 1 1 0 0 5 10 15 20 25 30 35 0 5 10 15 20 Input voltage (V) 25 30 35 Input voltage (V) Load Current vs. Ambient Temperature Models with Built-in Heat Sinks G3PE-235B-3(N), G3PE-245B-3(N) G3PE-235B-2(N), G3PE-245B-2(N) G3PE-535B-3(N), G3PE-545B-3(N) G3PE-535B-2(N), G3PE-545B-2(N) Load current (A) Load current (A) G3PE-215B-3(N), G3PE-225B-3(N) G3PE-215B-2(N), G3PE-225B-2(N) G3PE-515B-3(N), G3PE-525B-3(N) G3PE-515B-2(N), G3PE-525B-2(N) 30 25 20 15 10 G3PE-225B-3(N) G3PE-225B-2(N) G3PE-525B-3(N) G3PE-525B-2(N) 50 45 G3PE-245B-3(N) G3PE-245B-2(N) G3PE-545B-3(N) G3PE-545B-2(N) 40 35 G3PE-235B-3(N) 30 G3PE-235B-2(N) G3PE-535B-3(N) G3PE-535B-2(N) G3PE-215B-3(N) G3PE-215B-2(N) G3PE-515B-3(N) G3PE-515B-2(N) * 20 18 * The dotted lines in the charts are the UL derating curves for the G3PE-235B-3(N), G3PE-245B-3(N), G3PE-235B-2(N), G3PE-245B-2(N), G3PE-535B-3(N), G3PE-545B-3(N), G3PE-535B-2(N), G3PE-545B-2(N). 14 12 10 7 0 -30 -20 0 20 40 60 80 0 -30 -20 100 0 20 25 40 60 80 100 Ambient temperature (C) Ambient temperature (C) Models with Externally Attached Heat Sinks G3PE-235B-3H(-2H) G3PE-245B-3H(-2H) G3PE-535B-3H(-2H) G3PE-545B-3H(-2H) 10 Load current (A) Load current (A) G3PE-215B-3H(-2H) G3PE-225B-3H(-2H) G3PE-515B-3H(-2H) G3PE-525B-3H(-2H) 8 6 G3PE-225B-3H(-2H) G3PE-525B-3H(-2H) 10 G3PE-235B-3H(-2H) G3PE-245B-3H(-2H) G3PE-535B-3H(-2H) G3PE-545B-3H(-2H) 8 6 5 G3PE-215B-3H(-2H) 4 G3PE-515B-3H(-2H) 4 2 2 0 -30 -20 0 20 40 60 80 100 Ambient temperature (C) 0 -30 -20 0 20 25 40 60 80 100 Ambient temperature (C) 5 G3PE-Three-phase Inrush Current Resistance: Non-repetitive 200 150 250 Inrush current (A. Peak) 250 Inrush current (A. Peak) Inrush current (A. Peak) Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively. G3PE-235B-3(N)(H), G3PE-535B-3(N)(H) G3PE-215B-3(N)(H) G3PE-225B-3(N)(H), G3PE-525B-3(N)(H) G3PE-235B-2(N)(H), G3PE-535B-2(N)(H) G3PE-215B-2(N)(H) G3PE-225B-2(N)(H), G3PE-525B-2(N)(H) G3PE-245B-3(N)(H), G3PE-545B-3(N)(H) G3PE-515B-3(N)(H), G3PE-245B-2(N)(H), G3PE-545B-2(N)(H) G3PE-515B-2(N)(H), 200 150 500 400 300 100 100 200 50 50 100 0 10 30 50 100 300 500 1,000 0 10 3,000 5,000 30 50 100 300 500 1,000 0 10 3,000 5,000 Energized time (ms) Energized time (ms) 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) Heat Sink Area vs. Load Current (40C and 80C) G3PE-525B-3H 50,000 30,000 Ambient temperature + 80C 10,000 Ambient temperature + 40C 5,000 Heat sink area (cm 2) Heat sink area (cm 2) G3PE-225B-3H 50,000 30,000 Ambient temperature + 80C 10,000 Ambient temperature + 40C 5,000 3,000 3,000 Aluminum plate t = 3.0 Aluminum plate t = 3.0 1,000 1,000 500 500 300 300 Note: The heat sink area is the combined area of all surfaces of the heat sink that radiate heat. For the G3PE-525B-3H, when a current of 18 A flows through the SSR at 40C, the graph shows that a heat sink area of about 2,500 cm2 would be required. Therefore, if the heat sink is square, one side of an aluminum plate in the heat sink must be 36 cm or longer (2,500 (cm2)/2 = 36 cm (rounded to a whole number)). 100 100 0 10 20 30 0 40 10 Load current (A) 20 30 40 Load current (A) Models with Externally Attached Heat Sinks Heat Resistance Rth (Junction/SSR Back Surface) Model Rth (C/W) G3PE-215B-3H 1.05 G3PE-225B-3H 0.57 G3PE-235B-3H 0.57 G3PE-245B-3H 0.57 Heat Resistance of Heat Sinks Model Rth (C/W) Y92B-P50 1.67 Y92B-P100 1.01 Y92B-P150 0.63 Y92B-P200 0.43 Y92B-P250 0.36 Note: If a commercially available heat sink is used, use one that has a heat resistance equal to or lower than a standard OMRON Heat Sink. 6 G3PE-Three-phase Dimensions Note: All units are in millimeters unless otherwise indicated. Solid State Relays Models with DIN Track Mounting G3PE-215B-3N G3PE-215B-2N G3PE-225B-2N G3PE-515B-3N G3PE-515B-2N G3PE-525B-2N Two, 4.6-dia. mounting holes Four, 8 dia. Two, M3.5 84.5 100 90 max. max. 68 24 Two, R2.3 mounting holes 0.5 20 64 20 32.2 80 max. Six, M4 68 Note: Without terminal cover. Note: With terminal cover. Mounting Holes 35 19.1 23.2 max. 640.3 900.3 120 max. Four, 4.5 dia. or M4 Terminal Arrangement/Internal Circuit Diagram L2/S L3/T (+) L1/R L2/S L3/T A1 L3/T T2/V T3/W (-) L2/S L3/T T1/U T2/V T3/W (-) (+) A1 A2 A2 T1/U (-) L1/R A1 Input circuit Input circuit T3/W L2/S (+) A2 T1/U T2/V T3/W (-) Two, 4.6-dia. mounting holes Models with DIN Track Mounting Four, 8 dia. Two, M3.5 24 84.5 120 100 110 max. max. 68 Two, R2.3 mounting holes 0.5 20 64 Six, M5 (35-A type) Six, M4 (25-A type) 20 32.2 80 max. 68 Note: Without terminal cover. Note: With terminal cover. Mounting Holes 35 max. 19.1 23.2 640.3 1100.3 120 max. Four, 4.5 dia. or M4 Terminal Arrangement/Internal Circuit Diagram L2/S L3/T (+) L1/R L2/S L3/T A1 T2/V T3/W (-) L1/R L2/S G3PE-535B-2N L3/T Input circuit T2/V T3/W (-) L1/R L2/S L3/T T1/U T2/V T3/W (-) (+) A1 A2 A2 T1/U (+) A1 A1 A2 T1/U G3PE-525B-3N (+) Input circuit L1/R G3PE-235B-2N Input circuit G3PE-225B-3N Input circuit G3PE-225B-3N G3PE-235B-2N G3PE-525B-3N G3PE-535B-2N T2/V L1/R G3PE-5@5B-2N A1 A2 T1/U (+) Input circuit L1/R G3PE-515E-3N G3PE-2@5B-2N Input circuit G3PE-215B-3N A2 T1/U T2/V T3/W (-) 7 G3PE-Three-phase Models with DIN Track Mounting Two, 4.6-dia. mounting holes Four, 8 dia. G3PE-235B-3N G3PE-245B-2N G3PE-535B-3N G3PE-545B-2N Two, M3.5 24 84.5 140 120 130 max. max. 68 Two, R2.3 mounting holes 0.5 Six, M5 20 64 20 32.2 80 max. 68 Note: Without terminal cover. Note: With terminal cover. Mounting Holes 35 19.1 23.2 max. 640.3 120 max. 1300.3 Four, 4.5 dia. or M4 Terminal Arrangement/Internal Circuit Diagram L2/S L3/T (+) L1/R L2/S L3/T A1 T3/W L2/S L3/T T2/V T3/W (-) L1/R L2/S L3/T T1/U T2/V T3/W (+) A1 A2 A2 T1/U (-) (+) A1 Input circuit Input circuit Models with DIN Track Mounting T2/V L1/R G3PE-545B-2N A1 A2 T1/U (+) Input circuit L1/R G3PE-535B-3N G3PE-245B-2N Input circuit G3PE-235B-3N A2 T1/U (-) T2/V T3/W (-) Two, 4.6-dia. mounting holes Four, 8 dia. Two, M3.5 G3PE-245B-3N G3PE-545B-3N 24 Two, R2.3 mounting holes 0.5 Six, M5 20 84.5 140 120 130 max. max. 68 20 32.2 68 Note: Without terminal cover. 64 80 max. 110 max. Note: With terminal cover. Mounting Holes 35 19.1 23.2 max. 640.3 120 max. Terminal Arrangement/Internal Circuit Diagram G3PE-545B-3N G3PE245B-3N L1/R L2/S L3/T (+) L1/R L2/S L3/T A2 A2 T1/U T2/V T3/W (-) (+) A1 A1 Input circuit Four, 4.5 dia. or M4 Input circuit 1300.3 T1/U T2/V T3/W (-) 8 G3PE-Three-phase Models with Screw Mounting 4.6 dia. 50 G3PE-215B-2 G3PE-515B-2 84.5 90 100 max. max. 24 68 Two, M3.5 Six, M4 0.5 20 4.6 x 5.6 elliptical hole 20 32.2 80 max. Note: With terminal cover. 68 Note: Without terminal cover. DIN Track or screw mounting Mounting Holes Two, 4.5 dia. or M4 35 19.1 23.2 max. 900.3 55 max. Terminal Arrangement/Internal Circuit Diagram 500.3 G3PE-215B-2 L1/R L2/S G3PE-515B-2 L3/T (+) L1/R L2/S (+) L3/T Input circuit A1 Input circuit A1 A2 T1/U T2/V T3/W A2 T1/U (-) T2/V T3/W (-) Models with Screw Mounting G3PE-215B-3 G3PE-225B-2 G3PE-515B-3 G3PE-525B-2 Four, R2.5 5 24 60 68 Two, M3.5 0.5 20 20 80.5 84.5 max. 80 max. 90 Six, M4 32.2 100 110.5 max. 68 Note: Without terminal cover. Note: With terminal cover. Mounting Holes 35 19.1 23.2 max. Four, 4.5 dia. or M4 For screw mounting only 600.3 70 max. 1000.3 Terminal Arrangement/Internal Circuit Diagram L2/S L3/T G3PE-225B-2 (+) L1/R L2/S L3/T A1 T3/W (-) L2/S G3PE-525B-2 L3/T A2 T1/U T2/V T3/W (-) (+) L1/R L2/S L3/T A1 Input circuit Input circuit T2/V L1/R A1 A2 T1/U G3PE-515B-3 (+) A1 A2 T1/U T2/V T3/W (-) (+) Input circuit L1/R Input circuit G3PE-215B-3 A2 T1/U T2/V T3/W (-) 9 G3PE-Three-phase Models with Screw Mounting 5 Four, R2.5 G3PE-225B-3 G3PE-235B-2 G3PE-525B-3 G3PE-535B-2 84.5 90 110.5 max. max. 24 68 Two, M3.5 0.5 20 Six, M5 (G3PE-@35B-2) Six, M4 (G3PE-@25B-3) 20 32.2 80 max. 90 100 110.5 max. 68 Note: Without terminal cover. Note: With terminal cover. Mounting Holes Four, 4.5 dia. or M4 35 19.1 23.2 max. For screw mounting only 900.3 70 max. 1000.3 Terminal Arrangement/Internal Circuit Diagram L2/S L3/T L1/R L2/S L3/T A1 T3/W (-) L2/S L3/T A2 T1/U T2/V T3/W (-) (+) L1/R L2/S L3/T A1 Input circuit Input circuit Models with Screw Mounting T2/V L1/R G3PE-535B-2 A1 A2 T1/U G3PE-525B-3 (+) A1 A2 T1/U T2/V T3/W (+) Input circuit L1/R G3PE-235B-2 (+) Input circuit G3PE-225B-3 A2 T1/U (-) T2/V T3/W (-) L3/T (+) 5 Four, R2.5 G3PE-235B-3 G3PE-245B-2 G3PE-535B-3 G3PE-545B-2 84.5 90 130.5 max. max. 24 68 Two, M3.5 Six, M5 0.5 20 80 max. 110 20 32.2 120 68 130.5 max. Note: Without terminal cover. Mounting Holes Note: With terminal cover. Four, 4.5 dia. or M4 35 19.1 23.2 max. For screw mounting only 70 max. 900.3 1200.3 Terminal Arrangement/Internal Circuit Diagram L2/S L3/T (+) L1/R L2/S L3/T A1 T3/W (-) L2/S G3PE-545B-2 L3/T A2 T1/U T2/V T3/W (-) (+) L1/R L2/S A1 Input circuit Input circuit T2/V L1/R A1 A2 T1/U G3PE-535B-3 (+) A1 Input circuit L1/R G3PE-245B-2 Input circuit G3PE-235B-3 A2 T1/U T2/V T3/W (-) A2 T1/U T2/V T3/W (-) 10 G3PE-Three-phase Models with Screw Mounting G3PE-245B-3 G3PE-545B-3 5 Four, R2.5 84.5 150 190.5 max. max. 24 68 Two, M3.5 Six, M5 0.5 32.2 80 max. 110 120 130.5 max. Note: Without terminal cover. Note: With terminal cover. 20 20 68 Mounting Holes 35 19.1 23.2 max. Four, 4.5 dia. or M4 For screw mounting only 70 max. 1500.3 Terminal Arrangement/Internal Circuit Diagram G3PE-545B-3 G3PE-245B-3 L1/R L2/S L3/T (+) L1/R L2/S (+) L3/T A1 1200.3 Input circuit Input circuit A1 A2 A2 T1/U T2/V T3/W T1/U (-) T2/V T3/W (-) Models with Externally Attached Heat Sinks Four, 8 dia. Four, 4.5 dia. 9 8 dia. 4.5 dia. 24 68 80 84.5 max. Two, M3.5 0.5 20 80 max. 20 Note: With terminal cover. 32.2 68 Note: Without terminal Six, M4 (G3PE-@15B-@H/-@25B-@H) M5 cover.Six, (G3PE-@35B-@H/-@45B-@H) Mounting Holes Four, 4.5 dia. or M4 35 19.1 23.2 max. 680.3 680.3 Terminal Arrangement/Internal Circuit Diagram L2/S L3/T (+) L1/R L2/S L3/T A1 T2/V T3/W (-) L1/R L2/S L3/T Input circuit T2/V T3/W (-) L1/R L2/S L3/T T1/U T2/V T3/W (-) (+) A1 A2 A2 T1/U (+) A1 A1 A2 T1/U (+) G3PE-5@5B-2H Input circuit L1/R G3PE-5@5B-3H G3PE-2@5B-2H Input circuit G3PE-2@5B-3H Input circuit G3PE-215B-3H G3PE-215B-2H G3PE-225B-3H G3PE-225B-2H G3PE-235B-3H G3PE-235B-2H G3PE-245B-3H G3PE-245B-2H G3PE-515B-3H G3PE-515B-2H G3PE-525B-3H G3PE-525B-2H G3PE-535B-3H G3PE-535B-2H G3PE-545B-3H G3PE-545B-2H A2 T1/U T2/V T3/W (-) 11 G3PE-Three-phase Accessories (Order Separately) Heat Sink Heat Sink Y92B-P50 (Mounts to DIN Track.) For G3PE-215B-2H and G3PE-515B-2H Y92B-P100 For G3PE-215B-3H, G3PE-225B-2H, G3PE-515B-3H, and G3PE-525B-2H Four, M4 Mounting Holes 4.6 dia. 50 Mounting Holes 100 Two, 4.5 dia. or M4 Four, 4.5 dia. or M4 5 60 80.5 max. 68 68 4.6 x 5.6 elliptical hole 80.5 90 100 max. max. 600.3 900.3 1000.3 Four, R2.5 68 110.5 max. 500.3 68 80 max. 70 max. 55 max. Heat Sink Heat Sink Heat Sink Y92B-P150 For G3PE-225B-3H, G3PE-235B-2H, G3PE-525B-3H, and G3PE-535B-2H Y92B-P200 For G3PE-235B-3H, G3PE-245B-2H, G3PE-535B-3H, and G3PE-545B-2H Y92B-P250 For G3PE-245B-3H and G3PE-545B-3H Four, M4 120 120 100 Four, M4 5 5 90 110.5 max. 68 M4-D10 Four, M4 5 90 130.5 max. 68 190.5 150 max. 68 47.6 Four, R2.5 Four, R2.5 68 110.5 max. M4-D10 68 120 130.5 max. Four, R2.5 68 120 130.5 max. 70 max. 70 max. 70 max. Mounting Holes Mounting Holes Mounting Holes Four, 4.5 dia. or M4 Four, 4.5 dia. or M4 Four, 4.5 dia. or M4 900.3 900.3 1500.3 1000.3 1200.3 1200.3 12 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2011.3 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2011 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: G3PE-215B-2H DC12-24 G3PE-215B-2N DC12-24 G3PE-215B-2 DC12-24 G3PE-215B-3 DC12-24 G3PE-225B-2H DC12-24 G3PE-225B-2N DC12-24 G3PE-225B-3H DC12-24 G3PE-225B-3 DC12-24 G3PE-235B-2H DC12-24 G3PE-235B-2N DC12-24 G3PE-235B-2 DC12-24 G3PE-235B-3H DC12-24 G3PE-235B-3 DC12-24 G3PE-245B-2H DC12-24 G3PE-245B-2N DC12-24 G3PE-245B-2 DC12-24 G3PE-245B-3H DC12-24 G3PE-245B-3 DC12-24 G3PE515B-2H DC12-24 G3PE-515B-2 DC12-24 G3PE-515B-3H DC12-24 G3PE-515B-3 DC12-24 G3PE-525B-2H DC1224 G3PE-525B-2 DC12-24 G3PE-525B-3H DC12-24 G3PE-525B-3 DC12-24 G3PE-535B-2H DC12-24 G3PE-535B2 DC12-24 G3PE-535B-3H DC12-24 G3PE-535B-3 DC12-24 G3PE-545B-2H DC12-24 G3PE-545B-2 DC12-24 G3PE-545B-3H DC12-24 G3PE-545B-3 DC12-24 G3PE-515B-2N DC12-24 G3PE-515B-3N DC12-24 G3PE-525B-3N DC12-24 G3PE-535B-3N DC12-24 G3PE-545B-3N DC12-24 G3PE-215B-3N DC12-24 G3PE-225B-3N DC12-24 G3PE-245B-3N DC12-24