General Purpose Relay G7L 1
General Purpose Relay
G7L
Ideally suited for high-inrush fluid pump controls: pool/spa, water
processing, emergency, chemical industry, etc.
High-capacity,
high-withstand
voltage relay with no contact chatter-
ing for momentary voltage drops up to 50% of rated voltage.
UL Class B construction standard.
Wide-range AC-activated coil that handles 100 to 120 VAC or 200
to 240 VAC at either 50 or 60 Hz.
Miniature size for maximum switching capacity, particularly for
inductive loads.
Flame resistant materials (UL94V-0-qualifying) used for
all insulation material.
Quick-connect, screw, PCB terminals and DIN track mounting available.
Conforms to UL, CSA, TUV and meets IEC 950.
Safety design with contact gap of 3 mm.
RoHS Compliant. Note: Accessories: E-bracket, Adapter, Front-connecting socket
and Cover are sold separately.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G7L-1A-T-CB-AC100/120).
Note: 1. E bracket or socket must be used for mounting (part number R99-07G7L). Refer to “Accessories” section for options and part numbers.
2. For VDE approved versions, please consult OMRON.
List of E-Bracket Mounting Models
Type Contact form Model
Quick-connect terminal Screw terminal PCB terminal
E bracket (see note 1) SPST-NO G7L-1A-T-CB G7L-1A-B-CB
DPST-NO G7L-2A-T-CB G7L-2A-B-CB
E bracket (see note 1)
(with test button)
SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB
DPST-NO G7L-2A-TJ-CB G7L-2A-BJ-CB
Upper bracket SPST-NO G7L-1A-TUB-CB G7L-1A-BUB-CB
DPST-NO G7L-2A-TUB-CB G7L-2A-BUB-CB
Upper bracket
(with test button)
SPST-NO G7L-1A-TUBJ-CB G7L-1A-BUBJ-CB
DPST-NO G7L-2A-TUBJ-CB G7L-2A-BUBJ-CB
PCB mounting SPST-NO G7L-1A-P-CB
DPST-NO G7L-2A-P-CB
Mounting E-brackets DIN Track
Mounting
Adapter
Front-
connecting
Socket
Terminal
Contact
form Model Test button
Quick-
connect
terminals
SPST-NO G7L-1A-T - 
Note: Accessories: E-bracket (R99-07), Adapter (P7LF-D),
Front-connecting socket (P7LF-06) and Cover
(P7LF-C) are sold separately.
G7L-1A-TJ With test button 
DPST-NO G7L-2A-T - 
G7L-2A-TJ With test button 
Screw
terminals
SPST-NO G7L-1A-B - 
G7L-1A-BJ With test button 
DPST-NO G7L-2A-B - 
G7L-2A-BJ With test button 
2General Purpose Relay G7L
Model Number Legend
Accessories (Sold Separately)
Quick-connect Terminals
Note: A socket terminal cover is supplied with the P7LF-06 socket and does not attach directly to the G7L relays. It cannot be purchased separately.
Screw Terminals
Note: The P7LF-C terminal cover attaches directly to the G7L-B style relays. It is sold separately.
Specifications
Contact Data
Note: 1. P level: λ60 =0.1x10
-6 operation.
2. When using B-series (screw) products, since the screw diameter of the contact terminal is M4, be careful that the contact current should be 20 A or less
according to JET standard (electrical appliance and material control law of Japan).
Coil Internal Circuit
G7L- -❏❏❏---
1234567
1. Contact form 3. Mounting construction 5. 80: VDE approved version
1A:SPST-NO No symbol:E bracket type (includes UL, CSA and TÜV)
2A:DPST-NO UB:Upper bracket type
6. CB: Class B insulation
2. Terminal shape 4. Special functions
T:Quick-connect terminals (#250) No symbol:Without test button 7. Rated coil voltage
P:PCB terminals J:With test button
B:Screw terminals
Description Model Model
Contact form
SPST-NO DPST-NO
E-brackets G7L-1A-T G7L-1A-TJ G7L-2A-T G7L-2A-TJ R99-07G7L
Track mounting adapter P7LF-D
Front connecting socket P7LF-06
Description Model Model
Contact form
SPST-NO DPST-NO
E-brackets G7L-1A-B G7L-1A-BJ G7L-2A-B G7L-2A-BJ R99-07G7L
Track mounting adapter P7LF-D
Terminal Cover P7LF-C
Load G7L-1A-T@, G7L-1A-B@G7L-2A-T@, G7L-2A-B@G7L-1A-P, G7L-2A-P
Resistive load
(cosφ=1) Inductive load
(cosφ= 0.4) Resistive load
(cosφ=1) Inductive load
(cosφ= 0.4) Resistive load
(cosφ=1) Inductive load
(cosφ= 0.4)
Rated load 30 A, 220 VAC 25 A, 220 VAC 20 A, 220 VAC
Contact Type Double break
Contact material Ag alloy
Carry current 30 A 25 A 20 A
Max. operating voltage 250 VAC
Max. operating current 30 A 25 A 20 A
Max. switching capacity 6,600 VA 5,500 VA 4,400 VA
Min. permissible load 100 mA, 5 VDC (@ 60 operations / minute). Note: Do not use for switching microloads, such as signals.
01
01
DC operating coil AC operating coil Note: 1. The ratio of rated voltage between 100 to 120 VAC are values
measured on the basis of 100 VAC
2. When driving a transistor, check the leakage current and connect
a bleeder resistor if necessary.
3. The AC coil is provided with a built-in full-wave rectifier. If a triac,
such as an SSR, drives the G7L, the G7L may not release. Be sure
to perform a trial operation with the G7L and the triac before ap-
plying them to actual use.
General Purpose Relay G7L 3
Coil Data
AC
DC
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for AC rated current and
±15% for DC coil resistance.
2. The inductances shown above are reference values.
3. Performance characteristic data are measured at a coil temperature of 23°C.
4. The maximum allowable coil voltage refers to the maximum value in a varying range of operating power voltage, measured at ambient
temperature 23°C.
5. The “to” (for example “100 to 120”) represents a range of rated voltages.
Characteristics
Note: Data shown are of initial value.
Note: 1. Measurement conditions: 5 VDC, 1 A, voltage drop method.
2. Measurement conditions: Rated operating voltage applied, not including contact bounce, @ 23°C.
3. Measurement conditions: The insulation resistance was measured with a 500-VDC megohmeter at the same locations as the dielectric
strength was measured.
Rated voltage
(V) Rated current
(mA) Resistance
(Ω)Must operate Must release Max. voltage Power
consumption
% of rated voltage
12 142 75 75% max. 15% min. 110% max. Approx.1.70
to 2.50 VA
24 71 303
50 34 1,310
100 to 120 17.00 to 20.40 5,260 75 volts max. 18 volts min. 132 volts
200 to 240 8.50 to 10.20 21,000 150 volts max. 36 volts min. 264 volts
Rated voltage
(V) Rated current
(mA) Resistance
(Ω)Coil inductance (H) Must operate Must release Max. voltage Power
consumption
Armature
ON Armature
OFF % of rated voltage
6 317 18.90 0.9 0.21 75% max. 15% min. 110% max. Approx.1.90 W
12 158 75 0.37 0.88
24 79 303 1.42 3.54
48 40 1,220 6.1 15.3
100 19 5,260 21.3 60.0
Contact resistance (note 1) 50 mΩmax.
Operate time (note 2) 30 ms max.
Release time (note 3) 30 ms max.
Max. operating
frequency Mechanical 1,800 operations/hour
Electrical 1,800 operations/hour (under rated load)
Insulation resistance (note 3) 1,000 MΩmin. (at 500 VDC)
Dielectric strength 4,000 VAC, min., 50/60 Hz for 1 minute between coil and contacts
2,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
2,000 VAC, 50/60 Hz for 1 minute between contacts of different polarity (DPST-NO type)
Impulse withstand voltage
Between coil and contact: 10,000 V - JEC212 (1981) Standard Impulse Wave Type (1.20 x 50 μs)
Vibration Mechanical
durability 10 to 55 Hz; 1.50 mm double amplitude
Malfunction
durability 10 to 55 Hz; 1.50 mm double amplitude
Shock Mechanical
durability 1,000 m/s2(approx. 100 G)
Malfunction
durability 100 m/s2(approx.10 G)
Life expectancy Mechanical 1,000,000 operations min. (at 1,800 operations/hour)
Electrical @ 23°C100,000 operations min. (at 1,800 operations/hour under rated load)
Ambient operating temperature -25°to 60°C (with no icing or condensation)
Ambient operating humidity 5% to 85% RH
Weight Quick-connect terminal type: approx. 90 g
PCB terminal type: approx. 100 g
Screw terminal type: approx. 120 g
4General Purpose Relay G7L
Engineering Data
G7L-1A-T (TJ) (TUB) (TUBJ)
G7L-1A-B (BJ) (BUB) (BUBJ)
Maximum Switching Power
G7L-2A-T (TJ) (TUB) (TUBJ)
G7L-2A-B (BJ) (BUB) (BUBJ)
Maximum Switching Power
G7L-1A-P
G7L-2A-P
Maximum Switching Power
Ambient Temperature vs.
Operate and Release Voltage
G7L-1A VAC (60 Hz)
Endurance Endurance Endurance G7L-1A VDC
10 30 50 70 100 300 500 1,000
Switching voltage (V)
100
30
10
20
50
1
3
5
7
Switching current (A)
AC inductive load
(cosφ = 0.4)
AC resistive load
10 30 50 70 100 300 500 1,000
Ambient temperature (°C)
100
30
10
20
50
1
3
5
7
Switching current (A)
AC resistive load
AC inductive load
(cosφ = 0.4)
10 30 50 70 100 300 500
Switching voltage (V)
50
20
10
30
1
3
5
7
Switching current (A)
AC resistive load
AC inductive load
(cosφ = 0.4)
-40 -20 0 20 40 60 80
Ambient temperature (°C)
100
80
60
40
20
0
Operate and Release voltages (%)
Operate voltage
Release voltage
0 5 10 15 20 25 30
Switching current (A)
500
300
100
70
50
30
10
5
7
220 VAC resistive load
Endurance (x 10
4
operations)
220 VAC
inductive load
(cosφ = 0.4)
0 5 10 15 20 25 30
Switching current (A)
500
300
100
70
50
30
10
5
7
220 VAC resistive load
Endurance (x 10
4
operations)
220 VAC
inductive load
(cosφ = 0.4)
0 5 10 15 20 25 30
Switching current (A)
500
300
100
70
50
30
10
5
7
220 VAC resistive load
Endurance (x 10
4
operations)
220 VAC
inductive load
(cosφ = 0.4)
-40 -20 0 20 40 60 80
Ambient temperature (°C)
100
80
60
40
20
0
Operate and Release voltages (%)
Operate voltage
Release voltage
Ambient Temperature vs.
Coil Temperature Rise
G7L-1A 120 VAC (50 Hz) G7L-1A VDC
Shock Malfunction
G7L-2A-T (TUB) 100 to 120 VAC
-40
Ambient temperature (°C)
80
60
40
20
0
0 A
15 A
30 A
N=5
Coil Temperature Rise (
°C
)
-20 0 20 40 60 80
80
60
40
20
0
-40
Ambient temperature (°C)
0 A
15 A
30 A
N=5
Coil Temperature Rise (
°C
)
-20 0 20 40 60 80
Y
XZ'
X'
Z
100
100
200
300
400
500
100
300
400
500 200
100
300
400
500 200
500
300
200
100 400
100
200
300
400
500
200
300
400
500
Y'
Unit: (m/s
2
)
N = 5
Test method: The value at which
malfunction occurred
was measured after
applying shock to the
test piece 3 times
each in 6 directions
along 3 axes.
Standard: 100m/s
2
X
Y
X'
Momentary Voltage Drop Test
G7L-2A-T (TUB) 100 to 120 VAC
Test Circuit Wave resulted from test
Voltage distribution of wave e which
chattering does not occur.
Ch2
Ch1
Ch1
ON
OFF
(contact)
Ch2
(coil)
Rated
voltage
Without chattering
e
4020 60 80 100
On the basis of rated voltage (%)
8
6
4
2
0
Number of Relays
n=10
General Purpose Relay G7L 5
Characteristic variation resulted from different mounting directions
G7L-2A-T (TUB) 100 to 120 VAC
Operate time Release time Operate voltage Release voltage
Note: The mounting direction A’ deteriorates switching performance.
Actual Load Endurance Test
G7L-2A 100 to 200 VAC
Operate and Release voltages
N = 5 Contact resistance
Operate and Release voltages
N = 5 Contact resistance
Load conditions Load conditions
•1φ220 VAC 1 φ220 VAC
25
20
15
10
5
0
Time (ms)
A
To p
Bottom (Standard)
Mounting direction
(Note)
A' B B' C C'
N = 5
Operate time
Time (ms)
35
30
25
20
15
0A
To p
Bottom (Standard)
Mounting direction
(Note)
A' B B' C C'
N = 5
Release time
80
70
60
50
40
0
On the basis of rated voltage (%)
A
To p
Bottom(Standard)
Mounting direction
(Note)
A' B B' C C'
N = 5
Operate voltage
50
40
30
20
10
0
On the basis of rated voltage (%)
A
To p
Bottom(Standard)
Mounting direction
(Note)
A' B B' C C'
N = 5
Release voltage
0.70.5 1 3 5 7 10 30 50
Switching operations (×10
4
operations)
70
60
50
40
30
20
10
0
On the basis of rated voltage (%)
Operate voltage
Release voltage
N = 5
0.70.5 1 3 5 7 10 30 50
100
80
60
40
20
0
Contact resistance (mΩ)
N = 5
Switching operations (×10
4
operations)
0.070.05 0.1 0.3 0.5 1 3 5
70
60
50
40
30
20
10
0
On the basis of rated voltage (%)
Operate
voltage
Release
voltage
N = 5
Switching operations (×10
4
operations)
0.070.05 0.1 0.3 0.5 1 3 5
50
40
30
20
10
0
Contact resistance (mΩ)
N = 5
Switching operations (×10
4
operations)
70 A cosφ = 0.4
20 A cosφ = 0.4
0.2s
1s 1s
Applied coil voltage: 100% of rated
voltage
54 A cosφ = 0.79
(Compressor Lock Test)
0.5s 10s
Applied coil voltage: 100% of rated
voltage
G7L-2A 100 to 200 VAC
Operate and Release voltages
N = 5 Contact resistance
Operate and Release voltages
N = 5 Contact resistance
Load conditions Load conditions
•1φ220 VAC 1 φ220 VAC
0.70.5 1 3 5 10 30 50
Switching operations (×10
2
operations)
70
60
50
40
30
20
10
0
On the basis of rated voltage (%)
Operate voltage
Release voltage
N = 5
0.70.5 1 3 5 10 30 50
50
40
30
20
10
0
Contact resistance (mΩ)
N = 5
Switching operations (×10
2
operations)
0.70.5 1 3 5 10 30 50
70
60
50
40
30
20
10
0
On the basis of rated voltage (%)
Operate voltage
Release voltage
N = 5
Switching operations (×10
2
operations)
0.70.5 1 3 5 10 30 50
50
40
30
20
10
0
Contact resistance (mΩ)
N = 5
Switching operations (×10
2
operations)
Applied coil voltage: 75% of rated
voltage
25 A cosφ = 1
2s 8s
70 A cosφ = 0.4
20 A cosφ = 0.4
0.2s
2s 8s
Applied coil voltage: 75% of rated
voltage
6General Purpose Relay G7L
Applications
Compressors for package air conditioners and heater switching
controllers
Switching controllers for power tools or motors
Power controllers for water heaters
Power controllers for dryers
Lamp control, motor drivers, and power supply switching in copy
machines, facsimiles, and other office equipment
Lighting controllers
Power controllers for packers or food processing equipment
Magnetron control in microwaves
Power controllers for Uninterruptible Power Supplies (UPS)
Dimensions
Unit: mm (inch)
Relays
Quick-Connect Terminal Models
E-bracket Mounting*
Two, 4.5-dia. hole or
M4 tapped holes
11
52.5 max.
33.5 max.
53 max.
01
46
0.8
50.5 max.
6.35
11
52.5 max.
33.5 max.
53 max.
01
46
40±0.1
0.8
2
50.5 max.
6.35
11
52.5 max.
33.5 max.
53 max.
01
4268
0.8
2
50.5 max.
6.35
11
52.5 max.
33.5 max.
53 max.
01
4268
0.8
50.5 max.
6.35
Test
button
Test
button
G7L-1A-T
G7L-2A-T
G7L-1A-TJ
(with Test Button)
G7L-2A-TJ
(with Test Button)
Terminal arrangement/
Internal connections
(Top view)
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
Mounting holes
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
* E brackets are sold separately
General Purpose Relay G7L 7
Adapter Mounting*
Test button
Test button
Two, M4 or 4.5-dia.
holes
55.5 max.
55.5 max.
63 max.
51.5 max.
66.5 max.
63 max.
51.5 max.
66.5 max.
PFP-@N
PFP-@N
G7L
G7L
P7LF-D
P7LF-D
40±0.1
01
4
5
5
5
2
2
5
6
01
4268
55.5 max.
55.5 max.
63 max.
51.5 max.
66.5 max.
63 max.
51.5 max.
66.5 max.
PFP-@N
PFP-@N
G7L
G7L
P7LF-D
P7LF-D
01
46
01
4268
G7L-1A-T
G7L-2A-T
G7L-1A-TJ
(with Test Button)
G7L-2A-TJ
(with Test Button)
Terminal arrangement/
Internal connections
(Top view)
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
Mounting holes
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
* The DIN Track Mounting Adapter and DIN tracks are sold separately. The adapter can be track-mounted or screw-mounted.
8General Purpose Relay G7L
Front-connecting Socket Mounting*
51.5 max.
61.5 max.
55.5 max.
65 max.
51.5 max.
61.5 max.
55.5 max.
65 max.
PFP-@N 2-M3.5 × 6 (coil side)
4-M4 × 8 (contact side)
2-M3.5 × 6 (coil side)
4-M4 × 8 (contact side)
G7L
P7LF-06
PFP-@N G7L
P7LF-06
0 1
4
5
5
2
2
6
0 1
4 2 6 8
Test button
Test button
Two, M4 or 4.5-dia.
holes
51.5 max.
61.5 max.55.5 max.
65 max.
51.5 max.
61.5 max.55.5 max.
65 max.
PFP-@N2-M3.5 × 6 (coil side)
4-M4 × 8 (contact side)
2-M3.5 × 6 (coil side)
4-M4 × 8 (contact side)
G7L
P7LF-06
PFP-@NG7L
P7LF-06
40±0.1
01
4
5
5
6
01
4268
G7L-1A-T
G7L-2A-T
Terminal arrangement/
Internal connections
(Top view)
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
Mounting holes
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
* The Front-connecting Socket and DIN tracks are sold separately. The socket can be track-mounted or screw-mounted.
G7L-1A-TJ
(with Test Button)
G7L-2A-TJ
(with Test Button)
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
General Purpose Relay G7L 9
Upper Bracket Mounting
Two, 4.5-dia. hole or
M4 tapped holes
11
4.5
68.5 max.
33.5 max.
47 max.
01
46
01
4268
0.8
50.5 max.
6.35
60
11
2.5
4.5
68.5 max.
33.5 max.
47 max.
0.8
50.5 max.
6.35
60
11
2.5
4.5
68.5 max.
33.5 max.
47 max.
01
46
01
4268
0.8
2
2
50.5 max.
6.35
60
11
2.5
4.5
68.5 max.
33.5 max.
47 max.
0.8
50.5 max.
6.35
60
60±
0.2
Test
button
Test
button
G7L-1A-TUB
G7L-2A-TUB
Terminal arrangement/
Internal connections
(Top view)
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
Mounting holes
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
G7L-1A-TUBJ
(with Test Button)
G7L-2A-TUBJ
(with Test Button)
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
10 General Purpose Relay G7L
Screw Terminal Models
E-bracket Mounting*
Two, 4.5-dia. hole or
M4 tapped holes
52.5 max.
34.5 max.
55 max.
50.5 max.
01
46
40±0.1
2-M3.5 × 6
(coil side)
2-M4 × 8
(contact side)
52.5 max.
34.5 max.
55 max.
50.5 max.
2-M3.5 × 6
(coil side)
2-M4 × 8
(contact side)
52.5 max.
34.5 max.
55 max.
50.5 max.
2-M3.5 × 6
(coil side)
4-M4 × 8
(contact side)
01
4268
01
46
01
4268
2
Test
button
52.5 max.
34.5 max.
55 max.
50.5 max.
2-M3.5 × 6
(coil side)
4-M4 × 8
(contact side)
2
Test
button
G7L-1A-B
G7L-2A-B
G7L-1A-BJ
(with Test Button)
G7L-2A-BJ
(with Test Button)
Terminal arrangement/
Internal connections
(Top view)
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
Mounting holes
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
* E brackets are sold separately
General Purpose Relay G7L 11
Adapter Mounting*
51.5 max.
65.5 max. 55.5 max.
69 max.
51.5 max.
65.5 max.
55.5 max.
69 max.
PFP-@N 2-M3.5 × 6 (coil side)
2-M4 × 8 (contact side)
2-M3.5 × 6 (coil side)
4-M4 × 8 (contact side)
G7L
P7LF-D
PFP-@N G7L
P7LF-D
0 1
4
5
2
2
5
6
0 1
4 2 6 8
Test button
Test button
Two, M4 or 4.5-dia.
holes
51.5 max.
65.5 max. 55.5 max.
69 max.
51.5 max.
65.5 max.
55.5 max.
69 max.
PFP-@N 2-M3.5 × 6 (coil side)
2-M4 × 8 (contact side)
2-M3.5 × 6 (coil side)
4-M4 × 8 (contact side)
G7L
P7LF-D
PFP-@N G7L
P7LF-D
40±0.1
0 1
4
5
5
6
0 1
4 2 6 8
G7L-1A-B
G7L-2A-B
Terminal arrangement/
Internal connections
(Top view)
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
Mounting holes
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
* The DIN Track Mounting Adapter and DIN tracks are sold separately. The adapter can be track-mounted or screw-mounted.
G7L-1A-BJ
(with Test Button)
G7L-2A-BJ
(with Test Button)
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
12 General Purpose Relay G7L
Upper Bracket Mounting
PCB Terminal Models
Two, 4.5-dia. hole or
M4 tapped holes
2.5
4.5
68.5 max.
34.5 max.
49 max.
01
46
01
4268
50.5 max.
60
2.5
4.5
68.5 max.
34.5 max.
49 max.
50.5 max.
60
2.5
4.5
68.5 max.
34.5 max.
49 max.
01
46
01
4268
2
2
50.5 max.
60
2.5
68.5 max.
34.5 max.
49 max.
50.5 max.
60
60±0.2
Test
button
Test
button
2-M3.5 × 6
(coil side)
2-M3.5 × 6
(coil side)
2-M4 × 8
(contact side)
4-M4 × 8
(contact side)
2-M3.5 × 6
(coil side) 2-M4 × 8
(contact side)
2-M3.5 × 6
(coil side) 4-M4 × 8
(contact side)
G7L-1A-BUB
G7L-2A-BUB
Terminal arrangement/
Internal connections
(Top view)
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
Mounting holes
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
G7L-1A-BUBJ
(with Test Button)
G7L-2A-BUBJ
(with Test Button)
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
36.8
14.4
3.2
1.2
4-1.2 × 3.2 square hole
17.7
6
2.8 0.8
52.5 max.
41 max.
35.5 max.
47 max.
01
46
(8.4)
(8.9)
(8.4)
36.8
14.4
3.2
1.2
6-1.2 × 3.2 square hole
17.7
(8.9)
6
2.8 0.8
52.5 max.
41 max.
35.5 max.
47 max.
01
24 86
G7L-1A-P
G7L-2A-P
Terminal arrangement/
Internal connections
(Top view)
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
PCB Mounting holes
(Bottom view)
Tolerance ±0.1 mm
(No coil polarity)
Note: Refer to "Coil Internal Circuit" for the
coil internal connection diagram.
PCB Mounting holes
(Bottom view)
Tolerance ±0.1 mm
General Purpose Relay G7L 13
Accessories (Sold Separately)
E bracket
R99-07G7L
Adapter
P7LF-D
Front connecting socket
P7LF-06
Note: 1. To protect against electric shock, a socket terminal cover is supplied with the P7LF-06 socket. It cannot be purchased separately.
2. The P7LF-D and P7LF-06 are panel or track mountable.
3. The P7LF-D is for use with quick connect or screw models that accept the E-bracket.
4. The P7LF-06 is for use with quick connect models that accept the e-bracket.
Cover
P7LF-C
Note: P7LF-C cover attaches directly to G7L-B style relays. To protect against electric shock, use the P7LF-C on G7L-B terminals.
Two, 4.5-dia. hole
26 24
24
17.8
40
46 10
4.4
3
19.7
30
50
55
7
40
Two, M4 or 4.5-dia.
holes
Mounting holes
(Bottom view)
14.5 5
Two, M4 or 4.5-dia.
holes
55.5 max. 35.2 max.
51.5 max.
40±
0.1
40±
0.1
Mounting holes
(Bottom view)
40±
0.1
8±
0.05
9.2±
0.05
55.5 max.
46 max.
51.5 max.
25 5
Two, M4 or 4.5-dia.
holes
40±
0.1
2-M3.5 × 6 (coil side)
4-M4 × 8
(contact side)
Mounting holes
(Bottom view)
34.5 max.
50.5 max.
6 max.
1
14 General Purpose Relay G7L
Mounting track
Note: 1. It is recommended that a panel thickness of 1.60 to 2.00 mm (0.06 to 0.08 in) be used.
2. L = Length
PFP-100N L=1m(39.00 in)
PFP-50N L = 50 cm (19.60 in)
PFP-100N2 L=1m(39.00 in)
End plate
PFP-M
Spacer
PFP-S
4.5
15 25 25 25 25
*
10 10
1000 (500)*
7.3±0.15
35±0.3 27±0.15
15 (5) 1
4.5
15 25 25 25 25 15
10 10
1000±4
35±0.3 27 24
16
29.2
1 1.5
* The figure in parenthesis is for PFP-50N.
PFP-100N, PFP-50N
(Conforming to EN 50022) PFP-100N2
(Conforming to EN 50022)
General Purpose Relay G7L 15
Approvals
A variety of Safety Standard approved products for standard models.
UL approval (File No. E41643)
CSA approval (File No. LR31928)
Reference
UL Approved Type .....................................................
UL508 Industrial Control Devices
UL1950 Information processing equipment
(Including office equipment)
CSA Approved Type...................................................
CSA C22.2 No.1, 14
Industrial Control Devices
CSA C22.2 No.950 Information processing equipment
(Including office equipment)
TÜV EN/IEC Standard Approved Type.......................
EN61810-1 Relay
EN60950 Information processing equipment
(Including office equipment)
IEC950 Information processing equipment
(Including office equipment)
EN/IEC, TÜV Approval (File No. R50059083)
VDE recognized type (License no. 1530 UG)
Note: 1. Please consult OMRON for details of VDE approvals.
2. The G7L relay conforms to the following standards: Electrical safety: DIN IEC 255 Teil 1-00/DIN VDE 0435 Teil 201/05. 83
DIN VDE 0435 Teil 201 A1/05. 90
DIN IEC 255 Teil 0-20/DIN VDE 0435 Teil 120/10. 81
DIN EN 60 950/VDE 0805/11. 93
EMC: prEN 50082-2, EN 55022
3. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics
individually defined in this catalog.
4. In the interest of product improvement, specifications are subject to change.
5. Suffix T130 rated at 130°C
6. Pollution degree 3, Material Group II & III.
7. CE marking is provide only on non-PCB terminal versions.
Model Coil ratings Contact ratings
Number of test
operations
SPST-NO
G7L-1A-T@
G7L-1A-B@
G7L-1A-P
G7L-2A-T@
G7L-2A-B@
G7L-2A-P
12 to 240 VAC
6 to 220 VDC
30 A, 277 VAC (RES) 40°C 100,000
1.5 kW, 120 VAC (T) 40°C 6,000
1.5 HP, 120 VAC 40°C 1,000
3 HP 277 VAC 40°C 100,000
20 FLA/120 LRA, 120 VAC 40°C30,000
17 FLA/102 LRA, 277 VAC 40°C
TV-10, 120 VAC 40°C 25,000
Model Coil ratings Contact ratings Number of test
operations
SPST-NO
G7L-1A-P 12 to 240 VAC
6 to 220 VDC
2.4 kW, 120 VAC (T) 40°C 6,000
1.5 HP, 120 VAC (T) 40°C1,000
3 HP 277 VAC 40°C
20.5 FLA/105 LRA, 120 VAC 85°C 100,000
TV-10, 120 VAC 40°C 25,000
G7L-1A-T@
G7L-1A-B@
G7L-2A-T@
G7L-2A-B@
G7L-2A-P
12 to 240 VAC
6 to 220 VDC
30 A, 277 VAC (RES) 40°C 100,000
2.4 kW, 120 VAC (T) 40°C 6,000
1.5 HP, 120 VAC 40°C1,000
3 HP 277 VAC 40°C
20.5 FLA/105 LRA, 120 VAC 85°C 100,000
TV-10, 120 VAC 40°C 25,000
Model Coil ratings Contact ratings Approved
switching
operations
SPST-NO
G7L-1A-B@
6, 12, 24, 48,
100, 110, 200,
220 VDC
12, 24, 50,
100 to 120,
200 to 240
VAC
30 A, 250 VAC ~ (cosφ=1)60°C
25 A, 250 VAC ~ (cosφ= 0.4) 60°C
30 A, 120 VAC ~ (cosφ= 0.4) 60°C50,000
G7L-2A-B@
DPST-NO
50,000
25 A, 277 VAC ~ (cosφ=1)60°C
25 A, 277 VAC ~ (cosφ= 0.4) 60°C
G7L-1A-T@
SPST-NO
50,000
25 A, 240 VAC ~ (cosφ=1)60°C
25 A, 240 VAC ~ (cosφ= 0.4) 60°C
25 A, 277 VAC ~ (cosφ=1)60°C
25 A, 277 VAC ~ (cosφ= 0.4) 60°C
G7L-2A-T@
DPST-NO
50,000
25 A, 240 VAC ~ (cosφ=1)60°C
25 A, 240 VAC ~ (cosφ= 0.4) 60°C
25 A, 277 VAC ~ (cosφ=1)60°C
25 A, 277 VAC ~ (cosφ= 0.4) 60°C
G7L-1A-P
SPST-NO
50,000
20 A, 240 VAC ~ (cosφ=1)60°C
20 A, 240 VAC ~ (cosφ= 0.4) 60°C
25 A, 277 VAC ~ (cosφ=1)60°C
25 A, 277 VAC ~ (cosφ= 0.4) 60°C
G7L-2A-P
DPST-NO
50,000
20 A, 240 VAC ~ (cosφ=1)60°C
20 A, 240 VAC ~ (cosφ= 0.4) 60°C
25 A, 277 VAC ~ (cosφ=1)60°C
25 A, 277 VAC ~ (cosφ= 0.4) 60°C
16 General Purpose Relay G7L
Precautions
Correct Use
Handling
To preserve initial performance, do not drop or otherwise subject the
power relay to shock.
The case is not designed to be removed during normal handling and
operation. Doing so may affect performance.
Use the power relay in a dry environment free from excessive dust,
SO2,H
2S, or organic gas.
Do not allow a voltage greater than the maximum allowable coil volt-
age to be applied continuously.
Do not use the power relay outside of specified voltages and currents.
Do not allow the ambient operating temperature to exceed the speci-
fied limit.
Installation
Although there are not specific limits on the installation site, it should
be as dry and dust-free as possible.
Using in an atmosphere of high humidity and corrosive gas may
deteriorate its performance characteristic caused by condensation or
corrosive products, resulting in failure or burn damage of the Relay.
PCB terminal-equipped relays weigh approximately 100 g. Be sure
that the PCB is strong enough to support them. We recommend
dual-side through-hole PCBs to reduce solder cracking from heat
stress.
Relays with test buttons must be mounted facing down. Be careful
not to touch the test button accidentally. Doing so may turn on the
contact.
Be sure to use the test button for test purposes only (with test-button
models). The test button is used for Relay circuit tests, such as circuit
continuity tests. Do not attempt to switch the load with the test button.
Soldering PCB Terminals
Do not perform automatic soldering, but solder manually.
Do not wash down the entire Relay because it does not have an air-
tight construction.
Connecting
Refer to the following table when connecting a wire with a crimp style
terminal to the G7L.
Allow suitable slack on leads when wiring and do not apply excessive
force to the terminals.
Tightening torque;
Coil: 0.78 to 1.18 N·m
Contacts: 0.98 to 1.37 N·m
When connecting with screws, if the screws are not sufficiently tight-
ened, the lead wire can become detached and may lead to abnormal
heating or fire caused by faulty contact.
Do not apply excessive force when mounting or dismounting the
faston receptacle. Insert and remove terminals carefully, one at a
time. Do not insert terminals at an angle, or insert / remove multiple
terminals at the same time.
Do not connect to the terminals by soldering. Use #250 faston or
positive-lock connectors;
*the numbers shown in parentheses are for air-feeding.
Note: 1. The current should be 25A when using receptacle terminals.
2. Use receptacle terminals or positive housing for cable wiring.
Mounting
Top Bracket Type
Mounting torque; 0.98 N·m
Tighten with to M4 screws when mounting.
DIN Track Mounting Adapter and Front-Connecting Socket
The DIN Track Mounting Adapter and Front-connecting Socket can
be mounted on the G7L with just one hand and dismounted with
ease using a screwdriver.
To support the G7L mounted on a DIN Track Mounting Adapter or
Front-connecting Socket, use the PFP-M End Plate. Put the End
Plate onto the DIN Track Mounting Adapter or Front-connecting
Socket so that the surface mark of the End Plate faces upwards.
Then tighten the screw of the End Plate securely with a screwdriver.
Screw Mounting
Screw-mount the DIN Track Mounting Adapter or Front-connecting
Socket securely after opening screw mounting holes on them.
When cutting or opening holes on the panel after the Front-connect-
ing Socket is mounted, take proper measures so that the cutting
chips will not fall onto the Relay terminals. When cutting or opening
holes on the upper part of the panel, mask the Front-connecting
Socket properly with a cover.
Operating Coil
As a rule, either a battery or a DC power supply with a maximum
5% ripple is used for the operating voltage for DC relays. Before
using a rectified AC supply, confirm that the ripple is not greater
than 5%. Ripple greater than this can lead to variations in the oper-
ating and reset voltages.
As excessive ripple can generate beats, the insertion of a
smoothing capacitor is recommended as shown below.
When driving a transistor, check the leakage current and connect a
bleeder resistor if necessary.
Momentary voltage drops on coil input voltage should not exceed
one second duration after contact mating with no shock or vibra-
tion.
Screw Terminals Front Connecting Socket
Coil
Contact
8
5
M3.5
5.8
8
5.3
M3.5
6.5
9.2
5.5
M4
6.5
9.2
5.5
M4
7
Type Receptacle Terminals* Positive Housing
#250 terminals
(width: 6.35 mm)
AMP 170333-1 (170327-1)
AMP 170334-1 (170328-1)
AMP 170335-1 (170329-1)
AMP 172076-1 natural color
AMP 172076-4 yellow
AMP 172076-5 green
AMP 172076-5 blue
General Purpose Relay G7L 17
MEMO
18 General Purpose Relay G7L
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No. J055-E-09 Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
847-882-2288
08/14 (07/13) Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.