Ordering information AC-DC Power Supplies Open Frame/Enclosed type LDA10F LDA 1 10 2 F 3 -5 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series -O 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *2 C :with Coating G :Low leakage current S :with Chassis SN :with Chassis & cover Y :with Potentiometer *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LDA10F-3 6 3V 2.0A LDA10F-5 10 5V 2.0A LDA10F-12 10.8 12V 0.9A LDA10F-15 10.5 15V 0.7A LDA10F-24 12 24V 0.5A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] LDA INPUT FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C RIPPLE[mVp-p] -10 - 0C 0 to +50C RIPPLE NOISE[mVp-p] -10 - 0C TEMPERATURE REGULATION[mV] *1 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD INRUSH CURRENT[A] OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 * * * ACIN 100V ACIN 200V LDA10F-3 LDA10F-5 LDA10F-12 LDA10F-15 LDA10F-24 AC85 - 264 1f or DC110 - 370 0.25typ (Io=100%) 0.16typ (Io=100%) 47 - 440 or DC 68typ 72typ 74typ 74typ 78typ 15typ (Io=100%) (At cold start) 30typ (Io=100%) (At cold start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 12 15 24 2 2 0.9 0.7 0.5 20max 20max 48max 60max 96max 40max 40max 100max 120max 150max 80max 80max 120max 120max 120max 140max 140max 160max 160max 160max 120max 120max 150max 150max 150max 160max 160max 180max 180max 180max 50max 50max 120max 150max 240max 20max 20max 48max 60max 96max 200max (ACIN 100V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 100typ (ACIN 200V, Io=100%) 2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as option :5, 12, 15, 24V t10%) 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 xx Works over 105% of rating and recovers automatically 4.00V min Works over 115% of rating, by zener diode clamping Not provided Not provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 50X21X105mm (WXHXD) /75g max (without chassis and cover) Convection Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Please contact us about safety approvals for the model with option. Avoid prolonged use under over-load. Series/Parallel operation with other model is not possible. Derating is required when operated with chassis and cover. LDA-2 LDA10F External view LDA Performance data STATIC CHARACTERISTICS (LDA10F-5 ) RISE TIME & FALL TIME (LDA10F-5 ) OVERCURRENT CHARACTERISTICS (LDA10F-5 ) DERATING CURVE LDA-3 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LDA15F LDA 1 15 2 F 3 -5 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series -O 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *2 C :with Coating G :Low leakage current S :with Chassis SN :with Chassis & cover Y :with Potentiometer *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LDA15F-3 9 3V 3.0A LDA15F-5 15 5V 3.0A LDA15F-12 15.6 12V 1.3A LDA15F-15 15 15V 1.0A LDA15F-24 16.8 24V 0.7A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] LDA INPUT FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C RIPPLE[mVp-p] -10 - 0C 0 to +50C RIPPLE NOISE[mVp-p] -10 - 0C TEMPERATURE REGULATION[mV] *1 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD INRUSH CURRENT[A] OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 * * * ACIN 100V ACIN 200V LDA15F-3 LDA15F-5 LDA15F-12 LDA15F-15 LDA15F-24 AC85 - 264 1f or DC110 - 370 0.37typ (Io=100%) 0.23typ (Io=100%) 47 - 440 or DC 70typ 74typ 76typ 76typ 78typ 15typ (Io=100%) (At cold start) 30typ (Io=100%) (At cold start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 12 15 24 3 3 1.3 1 0.7 20max 20max 48max 60max 96max 40max 40max 100max 120max 150max 80max 80max 120max 120max 120max 140max 140max 160max 160max 160max 120max 120max 150max 150max 150max 160max 160max 180max 180max 180max 50max 50max 120max 150max 240max 20max 20max 48max 60max 96max 200max (ACIN 100V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 100typ (ACIN 200V, Io=100%) 2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as option :5, 12, 15, 24V t10%) 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 xx Works over 105% of rating and recovers automatically 4.00V min Works over 115% of rating, by zener diode clamping Not provided Not provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 50X21X125mm (WXHXD) /95g max (without chassis and cover) Convection Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Please contact us about safety approvals for the model with option. Avoid prolonged use under over-load. Series/Parallel operation with other model is not possible. Derating is required when operated with chassis and cover. LDA-4 LDA15F External view LDA Performance data STATIC CHARACTERISTICS (LDA15F-5 ) RISE TIME & FALL TIME (LDA15F-5 ) OVERCURRENT CHARACTERISTICS (LDA15F-5 ) DERATING CURVE LDA-5 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LDA30F LDA 1 30 2 F 3 -5 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series -O 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *2 C :with Coating G :Low leakage current S :with Chassis SN :with Chassis & cover Y :with Potentiometer *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT LDA30F-3 18 3V 6.0A LDA30F-5 30 5V 6.0A LDA30F-12 30 12V 2.5A LDA30F-15 30 15V 2.0A LDA30F-24 31.2 24V 1.3A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] LDA INPUT FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C RIPPLE[mVp-p] -10 - 0C 0 to +50C RIPPLE NOISE[mVp-p] -10 - 0C TEMPERATURE REGULATION[mV] *1 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD INRUSH CURRENT[A] OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 * * * ACIN 100V ACIN 200V LDA30F-3 LDA30F-5 LDA30F-12 LDA30F-15 LDA30F-24 AC85 - 264 1f or DC110 - 370 0.8typ (Io=100%) 0.4typ (Io=100%) 47 - 440 or DC 70typ 75typ 77typ 78typ 79typ 15typ (Io=100%) (At cold start) 30typ (Io=100%) (At cold start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 12 15 24 6 6 2.5 2 1.3 20max 20max 48max 60max 96max 40max 40max 100max 120max 150max 80max 80max 120max 120max 120max 140max 140max 160max 160max 160max 120max 120max 150max 150max 150max 160max 160max 180max 180max 180max 60max 60max 150max 180max 290max 20max 20max 48max 60max 96max 200max (ACIN 100V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as option :5, 12, 15, 24V t10%) 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 xx Works over 105% of rating and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating Not provided Not provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 55X26X133mm (WXHXD) /200g max (without chassis and cover) Convection Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Please contact us about safety approvals for the model with option. Avoid prolonged use under over-load. Series/Parallel operation with other model is not possible. Derating is required when operated with chassis and cover. LDA-6 LDA30F External view LDA Performance data STATIC CHARACTERISTICS (LDA30F-5 ) RISE TIME & FALL TIME (LDA30F-5 ) OVERCURRENT CHARACTERISTICS (LDA30F-5 ) DERATING CURVE LDA-7 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LDA50F LDA 1 50 2 F 3 -5 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT *3 -O 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *4 C :with Coating G :Low leakage current R :with Remote ON/OFF S :with Chassis SN :with Chassis & cover Y :with Potentiometer LDA50F-3 LDA50F-5 LDA50F-9 LDA50F-12 LDA50F-15 LDA50F-18 LDA50F-24 LDA50F-24-H LDA50F-24-HR LDA50F-30 30 50 50.4 51.6 52.5 50.4 50.4 50.4 50.4 51 3V 10A 5V 10A 9V 5.6A 12V 4.3A 15V 3.5A 18V 2.8A 24V 2.1A 24V 2.1(3)A 24V 2.1(3)A 30V 1.7A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] LDA INPUT FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] *1 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C RIPPLE[mVp-p] -10 - 0C 0 to +50C RIPPLE NOISE[mVp-p] -10 - 0C TEMPERATURE REGULATION[mV] *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD INRUSH CURRENT[A] OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 100V ACIN 200V LDA50F-3 LDA50F-5 LDA50F-9 LDA50F-12 LDA50F-15 LDA50F-18 LDA50F-24 LDA50F-24-H LDA50F-24-HR LDA50F-30 AC85 - 264 1f or DC110 - 370 1.3typ (Io=100%) 0.7typ (Io=100%) 47 - 440 or DC 73typ 77typ 78typ 80typ 81typ 81typ 82typ 82typ 82typ 82typ 15typ (Io=100%) (At cold start) 30typ (Io=100%) (At cold start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 9 12 15 18 24 24 24 30 10 10 5.6 4.3 3.5 2.8 2.1 2.1 (3) 2.1 (3) 1.7 20max 20max 36max 48max 60max 72max 96max 96max 96max 120max 40max 40max 100max 100max 120max 120max 150max 150max 150max 180max 80max 80max 120max 120max 120max 120max 120max 120max 120max 120max 140max 140max 160max 160max 160max 160max 160max 160max 160max 160max 120max 120max 150max 150max 150max 150max 150max 250max 250max 150max 160max 160max 180max 180max 180max 180max 180max 280max 280max 180max 60max 60max 120max 150max 180max 200max 290max 290max 290max 360max 20max 20max 36max 48max 60max 72max 96max 96max 96max 120max 200max (ACIN 100V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as option :5, 9, 12, 15, 18, 24, 30V t10%) 4.9 - 5.3 8.6 - 9.4 11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 23.0 - 25.0 28.5 - 31.5 xx Works over 105% of rating (-H : peak) and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating Not provided Not provided Option (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 55X26X195mm (WXHXD) /250g max (without chassis and cover) Convection *1 Peak load for 10sec. or less is acceptable if the total wattage is less than the rated wattage(24V:50.4W). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,with the input voltage held constant at the rated input/output. *3 ( ) : peak current *4 Please contact us about safety approvals for the model with option. LDA-8 * * * Avoid prolonged use under over-load. Parallel operation with other model is not possible. Derating is required when operated with chassis and cover. LDA50F External view LDA Performance data STATIC CHARACTERISTICS (LDA50F-5 ) RISE TIME & FALL TIME (LDA50F-5 ) OVERCURRENT CHARACTERISTICS (LDA50F-5 ) DERATING CURVE LDA-9 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LDA75F LDA 1 75 2 F 3 -5 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT *3 -O 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *4 C :with Coating G :Low leakage current L :with LED R :with Remote ON/OFF S :with Chassis SN :with Chassis & cover Y :with Potentiometer LDA75F-3 LDA75F-5 LDA75F-9 LDA75F-12 LDA75F-15 LDA75F-18 LDA75F-24 LDA75F-24-H LDA75F-24-HR LDA75F-30 45 75 76.5 75.6 75 75.6 76.8 76.8 76.8 75 3V 15A 5V 15A 9V 8.5A 12V 6.3A 15V 5A 18V 4.2A 24V 3.2A 24V 3.2(4.5)A 24V 3.2(4.5)A 30V 2.5A SPECIFICATIONS MODEL VOLTAGE[V] LDA CURRENT[A] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 100V ACIN 200V LDA75F-3 LDA75F-5 LDA75F-9 LDA75F-12 LDA75F-15 LDA75F-18 LDA75F-24 LDA75F-24-H LDA75F-24-HR LDA75F-30 AC85 - 264 1f or DC110 - 370 1.8typ (Io=100%) 1.0typ (Io=100%) 47 - 440 73typ 79typ 79typ 80typ 81typ 81typ 82typ 82typ 82typ 82typ 30typ (Io=100%) (At cold start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 9 12 15 18 24 24 24 30 15 15 8.5 6.3 5 4.2 3.2 3.2 (4.5) 3.2 (4.5) 2.5 20max 20max 36max 48max 60max 72max 96max 96max 96max 120max 40max 40max 100max 100max 120max 120max 150max 150max 150max 180max 80max 80max 120max 120max 120max 120max 120max 120max 120max 120max 140max 140max 160max 160max 160max 160max 160max 160max 160max 160max 120max 120max 150max 150max 150max 150max 150max 250max 250max 150max 160max 160max 180max 180max 180max 180max 180max 280max 280max 180max 60max 60max 120max 150max 180max 200max 290max 290max 290max 360max 20max 20max 36max 48max 60max 72max 96max 96max 96max 120max 200max (ACIN 100V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.6 Fixed ("Y"which can be adjusted the output is available as option : 5, 9, 12, 15, 18, 24, 30V t10%) 4.9 - 5.3 8.6 - 9.4 11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 23.0 - 25.0 28.5 - 31.5 xx Works over 105% of rating (-H : peak) and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating Not provided Not provided Option (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 55X32X222mm (WXHXD) /320g max (without chassis and cover) FREQUENCY[Hz] EFFICIENCY[%] INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] *1 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C RIPPLE[mVp-p] -10 - 0C 0 to +50C RIPPLE NOISE[mVp-p] -10 - 0C TEMPERATURE REGULATION[mV] *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD Convection *1 Peak load for 10sec. or less is acceptable if the total wattage is less than the rated wattage(24V:76.8W). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,with the input voltage held constant at the rated input/output. *3 ( ) : peak current *4 Please contact us about safety approvals for the model with option. LDA-10 * * * Avoid prolonged use under over-load. Parallel operation with other model is not possible. Derating is required when operated with chassis and cover. LDA75F External view B6P-VH LDA Performance data STATIC CHARACTERISTICS (LDA75F-5 ) RISE TIME & FALL TIME (LDA75F-5 ) OVERCURRENT CHARACTERISTICS (LDA75F-5 ) DERATING CURVE LDA-11 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LDA100W LDA 100 1 2 W 3 -5 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT *3 -O 5 1Series name 2Output wattage 3Autoranging input 4Output voltage 5Optional *4 C :with Coating G :Low leakage current R :with Remote ON/OFF S :with Chassis SN :with Chassis & cover Y :with Potentiometer LDA100W-3 LDA100W-5 LDA100W-9 LDA100W-12 LDA100W-15 LDA100W-18 LDA100W-24 LDA100W-24-H LDA100W-30 LDA100W-48 60 100 103.5 102 100.5 100.8 103.2 103.2 105 96 3V 20A 5V 20A 9V 11.5A 12V 8.5A 15V 6.7A 18V 5.6A 24V 4.3A 24V 4.3(6.5)A 30V 3.5A 48V 2.0A SPECIFICATIONS MODEL VOLTAGE[V] LDA CURRENT[A] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 100V ACIN 200V FREQUENCY[Hz] EFFICIENCY[%] INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] *1 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C RIPPLE[mVp-p] -10 - 0C 0 to +50C RIPPLE NOISE[mVp-p] -10 - 0C TEMPERATURE REGULATION[mV] *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD LDA100W-3 LDA100W-5 LDA100W-9 LDA100W-12 LDA100W-15 LDA100W-18 LDA100W-24 LDA100W-24-H LDA100W-30 LDA100W-48 AC 85 - 132 / 170 - 264 1f 2.4typ (Io=100%) 1.2typ (Io=100%) 47 - 440 75typ 79typ 80typ 81typ 82typ 82typ 83typ 83typ 83typ 82typ 30typ (Io=100%) (At cold start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 9 12 15 18 24 24 30 48 20 20 11.5 8.5 6.7 5.6 4.3 4.3 (6.5) 3.5 2.0 20max 20max 36max 48max 60max 72max 96max 96max 120max 192max 40max 40max 100max 100max 120max 120max 150max 150max 180max 240max 80max 80max 120max 120max 120max 120max 120max 120max 120max 150max 140max 140max 160max 160max 160max 160max 160max 160max 160max 200max 120max 120max 150max 150max 150max 150max 150max 250max 150max 400max 160max 160max 180max 180max 180max 180max 180max 280max 180max 600max 60max 60max 120max 150max 180max 200max 290max 290max 360max 560max 20max 20max 36max 48max 60max 72max 96max 96max 120max 192max 200max (ACIN 100V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.6 4.5 - 5.5 Fixed ("Y"which can be adjusted the output is available as option :9, 12, 15, 18, 24, 30, 48V t10%) 8.6 - 9.4 11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 28.8 - 31.2 46.0 - 50.0 xx xx Works over 105% of rating (-H : peak) and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating Not provided Not provided Option (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 62X35X222mm (WXHXD) /360g max (without chassis and cover) Convection *1 Peak load for 20sec. or less is acceptable if the total wattage is less than the rated wattage(24V:103.2W). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 ( ) : peak current *4 Please contact us about safety approvals for the model with option. LDA-12 * * * Avoid prolonged use under over-load. Parallel operation with other model is not possible. Derating is required when operated with chassis and cover. LDA100W External view LDA Performance data STATIC CHARACTERISTICS (LDA100W-5) RISE TIME & FALL TIME (LDA100W-5) OVERCURRENT CHARACTERISTICS (LDA100W-5) DERATING CURVE 100 LOAD FACTOR % 80 60 Convection Forced Air(0.5m3/min) 40 20 -10 0 10 20 30 40 50 60 70 AMBIENT TEMPARATURE C LDA-13 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LDA150W LDA 150 1 2 W 3 -5 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT *3 -O 5 1Series name 2Output wattage 3Autoranging input 4Output voltage 5Optional *4 C :with Coating G :Low leakage current L :with LED R :with Remote ON/OFF S :with Chassis SN :with Chassis & cover Y :with Potentiometer LDA150W-3 LDA150W-5 LDA150W-9 LDA150W-12 LDA150W-15 LDA150W-18 LDA150W-24 LDA150W-24-H LDA150W-30 LDA150W-48 90 150 153 150 150 153 151.2 151.2 150 144 3V 30A 5V 30A 9V 17A 12V 12.5A 15V 10A 18V 8.5A 24V 6.3A 24V 6.3(10)A 30V 5A 48V 3A SPECIFICATIONS MODEL VOLTAGE[V] LDA CURRENT[A] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 100V ACIN 200V FREQUENCY[Hz] EFFICIENCY[%] INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] *1 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C RIPPLE[mVp-p] -10 - 0C 0 to +50C RIPPLE NOISE[mVp-p] -10 - 0C TEMPERATURE REGULATION[mV] *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD LDA150W-3 LDA150W-5 LDA150W-9 LDA150W-12 LDA150W-15 LDA150W-18 LDA150W-24 LDA150W-24-H LDA150W-30 LDA150W-48 AC 85 - 132 / 170 - 264 1f 3.6typ (Io=100%) 2.0typ (Io=100%) 47 - 440 75typ 79typ 79typ 82typ 83typ 84typ 85typ 85typ 85typ 82typ 30typ (Io=100%) (At cold start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 9 12 15 18 24 24 30 48 30 30 17 12.5 10 8.5 6.3 6.3(10) 5 3 20max 20max 36max 48max 60max 72max 96max 96max 120max 192max 40max 40max 100max 100max 120max 120max 150max 150max 180max 240max 80max 80max 120max 120max 120max 120max 120max 220max 120max 150max 140max 140max 160max 160max 160max 160max 160max 260max 160max 200max 120max 120max 150max 150max 150max 150max 150max 250max 150max 400max 160max 160max 180max 180max 180max 180max 180max 280max 180max 600max 60max 60max 120max 150max 180max 200max 290max 290max 360max 560max 20max 20max 36max 48max 60max 72max 96max 96max 120max 192max 200max (ACIN 100V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.6 4.5 - 5.5 Fixed ("Y"which can be adjusted the output is available as option :9, 12, 15, 18, 24, 30, 48V t10%) 8.6 - 9.4 11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 28.5 - 31.5 46.0 - 50.0 xx xx Works over 105% of rating (-H : peak) and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating Not provided Not provided Option (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 75X37X222mm (WXHXD) /510g max (without chassis and cover) Convection *1 Peak load for 10sec. or less is acceptable if the total wattage is less than the rated wattage(24V:151.2W). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 ( ) : peak current *4 Please contact us about safety approvals for the model with option. LDA-14 * * * Avoid prolonged use under over-load. Parallel operation with other model is not possible. Derating is required when operated with chassis and cover. LDA150W External view LDA Performance data STATIC CHARACTERISTICS (LDA150W-5 ) RISE TIME & FALL TIME (LDA150W-5 ) OVERCURRENT CHARACTERISTICS (LDA150W-5 ) DERATING CURVE LDA-15 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LDA300W LDA 300 1 2 W 3 -5 4 Recommended EMI/EMC Filter NAC-16-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended *to connect with several devices. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT -O 5 1Series name 2Output wattage 3Autoranging input 4Output voltage 5Optional *4 C :with Coating G :Low leakage current L :with LED R :with Remote ON/OFF S :with Chassis SNF :with Chassis & cover & fan T :Vertical terminal block LDA300W-3 LDA300W-5 LDA300W-9 LDA300W-12 LDA300W-15 LDA300W-18 LDA300W-24 LDA300W-30 LDA300W-48 180 300 306 324 330 306 336 300 302.4 3V 60A 5V 60A 9V 34A 12V 27A 15V 22A 18V 17A 24V 14A 30V 10A 48V 6.3A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] LDA ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 * * ACIN 100V ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] Forced air CURRENT[A] Convection *1 LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *2 RIPPLE[mVp-p] -10 - 0C *2 0 to +50C *2 RIPPLE NOISE[mVp-p] -10 - 0C *2 TEMPERATURE REGULATION[mV] *3 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] LDA300W-3 LDA300W-5 LDA300W-9 LDA300W-12 LDA300W-15 LDA300W-18 LDA300W-24 LDA300W-30 AC 85 - 132 / 170 - 264 1f 7.5typ (Io=100%) 4.5typ (Io=100%) 47 - 440 72typ 78typ 78typ 80typ 81typ 81typ 83typ 83typ 74typ 81typ 81typ 83typ 84typ 84typ 86typ 86typ 15/30A typ (Primary/Secondary Surge Current) Io=100% (More than 3sec.to re-start) 30/30typ (Primary/Secondary Surge Current) Io=100% (More than 3sec.to re-start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 9 12 15 18 24 30 60 60 34 27 22 17 14 10 40 (60) 40 (60) 23 (34) 17 (27) 14 (22) 12 (17) 9 (14) 7 (10) 20max 20max 36max 48max 60max 72max 96max 120max 40max 40max 100max 100max 120max 120max 150max 180max 80max 80max 120max 120max 120max 120max 120max 120max 140max 140max 160max 160max 160max 160max 160max 160max 120max 120max 150max 150max 150max 150max 150max 150max 160max 160max 180max 180max 180max 180max 180max 180max 60max 60max 120max 150max 180max 200max 290max 360max 20max 20max 36max 48max 60max 72max 96max 120max 200max (ACIN 100V, Io=100%) 10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.6 5, 9, 12, 15, 18, 24, 30, 48V t10% Works over 105% of rating and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating Not provided Provided Option (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) -10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 108X50X255mm (WXHXD) /1kg max (without terminal block) Convection / Forced air (Refer to DERATING CURVE) Peak load for 30sec. or less is acceptable if the total wattage is less than the rated wattage. This is the value that measured on measuring board with capacitor of 22mF within 150mm from output terminal. Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. Please contact us about safety approvals for the model with option. Parallel operation with other model is not possible. Derating is required when operated with chassis and cover. LDA-16 LDA300W-48 83typ 86typ 48 6.3 4.2 (6.3) 192max 240max 150max 200max 400max 600max 560max 192max LDA300W External view Applicable options Terminal Block Horizontal type Terminal Block Vertical type -S Available -ST Available -SN Not Available -SNT Not Available -SNF Available 5V, 12V, 24V -SNFT Not Available CN1(Connector for Sensing) Type: B4B-XH-A Pin No. Function 1 -M 2 -S(Remote Sensing) 3 +S(Remote Sensing) 4 +M Mating Housing & Pin Mfr: J.S.T. XHP-4(BXH-001T-P0.6 or SXH-001T-P0.6) CN2(Optional connector for Remote ON/OFF: optional) Type: B2B-XH-A Pin No. Function 1 RC(+) 2 RC(-) LDA Mating Housing & Pin Mfr: J.S.T. XHP-2(BXH-001T-P0.6 or SXH-001T-P0.6) Performance data STATIC CHARACTERISTICS (LDA300W-5 ) RISE TIME & FALL TIME (LDA300W-5 ) OVERCURRENT CHARACTERISTICS (LDA300W-5 ) DERATING CURVE LDA-17 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Cosel: S-LDA300 N-LDA75 N-LDA150 N-LDA10 S-LDA15 N-LDA30 S-LDA150 S-LDA50 S-LDA10 N-LDA100 SLDA100 N-LDA50 S-LDA75 S-LDA30 N-LDA15 LDA50F-5-SNR LDA100W-24-H LDA100W-30-SNY LDA30F-24SNG LDA75F-12-S LDA50F-12-Y LDA75F-24-SY LDA150W-9-RY LDA300W-5-RT LDA10F-12-SNY LDA150W-48SN LDA100W-48 LDA30F-12-SY LDA50F-24-GY LDA300W-3-CT LDA300W-24-R LDA150W-12-CR LDA75F-5-CY LDA10F-24-M LDA50F-24-S LDA30F-24 LDA100W-15-RY LDA15F-5-GY LDA150W-18 LDA15F-15-GY LDA10F3-SNC LDA75F-12-M LDA150W-24-CR LDA50F-12-R LDA75F-24-R LDA75F-30-SNR LDA50F-3-M LDA30F-24SN LDA15F-3-S LDA75F-5-V LDA75F-15-Y LDA300W-3-R LDA10F-15-SNQ LDA50F-24-SN LDA100W-9-Y LDA50F-15-SN LDA150W-30-TD28 LDA300W-48-S LDA30F-15-SNY LDA50F-9-SNC LDA10F-5-S LDA75F-9-SN LDA150W-5-L LDA150W-30 LDA300W-30-CT LDA150W-12-Y LDA100W-48-SNY LDA150W-3-C LDA30F-5-Y LDA75F-12-SNY LDA30F-12-G LDA75F-24-C LDA100W-12-SNRY LDA300W-24-C LDA100W-24-SNH LDA15F-5Q LDA50F-30 LDA75F-15 LDA75F-9-Y LDA50F-5-G LDA30F-3-SNC LDA15F-24-CG LDA10F-5-SNC LDA30F-3GD3.3 LDA50F-24-CR LDA100W-48-CY LDA100W-5-CR LDA150W-24-SHY LDA10F-24-SNY LDA75F-3-SN LDA50F-30-SNRY LDA10F-5-SNY LDA300W-24-L LDA100W-5-SNC LDA300W-30-R LDA15F-12-S LDA100W-24HY LDA50F-24-HY LDA50F-5-Y LDA15F-12-Y