Data Sheet April 2008 LAW005-Series Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input; 5 W Features n Small footprint: 32 mm x 20 mm (1.25 in. x 0.8 in.) n Low profile: 10.7 mm (0.42 in.) n Wide input voltage range: 36 Vdc to 75 Vdc n Input-to-output isolation: 1500 Vdc n The LAW005-Series Power Modules use advanced, surfacemount technology and deliver high-quality, compact, dc-dc conversion at an economical price. n 12.5 W per cubic inch n Metal case n Burn in 4 hours @ 50 C, full load n Output overcurrent protection, unlimited duration n Output overvoltage protection n Applications n n Communication equipment n Computer equipment Operating ambient temperature range: -25 C to +71 C with no derating n UL* 60950 Recognized, CSA C22.2 No. 60950-00 Certified, VDE 0805 (IEC60950) Licensed CE mark meets 73/23/EEC and 93/68/EEC directives Within FCC Class A radiated limits Options n Short pins: 2.8 mm 0.25 mm (0.110 in. 0.010 in.) Description The LAW005-Series Power Modules are low-profile dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide precisely regulated single or dual outputs. The -25 C to +71 C operating temperature range makes it ideal for electronic data processing applications. The outputs are isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have a maximum power rating of 5 W and a typical full-load efficiency of 80%. Built-in filtering for both input and output minimizes the need for external filtering. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should be followed. (The CE mark is placed on selected products.) LAW005-Series Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input; 5 W Data Sheet April 2008 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Symbol Min Max Unit VI VI, trans 0 0 80 100 Vdc V Operating Ambient Temperature* (natural convection) TA -25 71 C Storage Temperature Tstg -55 105 C I/O Isolation Voltage -- -- 1500 Vdc Input Voltage: Continuous Transient (100 ms) * At IO = IO, max, derate linearly to 0 W at 100 C. Unit guaranteed to start at -40 C. All parameters will be within specification at TA = -25 C. Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage and resistive load from -25 C to +71 C. Table 1. Input Specifications Parameter Symbol Min Typ Max Unit VI 36 48 75 Vdc II, max -- 250 -- mA Inrush Transient i 2t -- 0.008 -- A2s Input Reflected-ripple Current (See Figure 1.) II -- 5 -- mAp-p Operating Input Voltage Input Current (VI = 0 V to VI, max; IO = IO, max) Fusing Considerations CAUTION: This power module is not internally fused. An input line fuse must always be used. This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer's data for further information. 2 Lineage Power Data Sheet April 2008 LAW005-Series Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input; 5 W Electrical Specifications (continued) Table 2. Output Specifications Parameter Device Symbol Min Typ Max Unit LAW005F LAW005A LAW005B LAW005C LAW005BK VO, set VO, set VO, set VO, set VO1, set VO2, set VO1, set VO2, set 3.26 4.95 11.88 14.85 11.88 11.88 14.85 14.85 3.3 5.00 12.00 15.00 12.00 12.00 15.00 15.00 3.33 5.05 12.12 15.15 12.12 12.12 15.15 15.15 Vdc Vdc Vdc Vdc Vdc Vdc Vdc Vdc VO VO VO VO VO1 VO2 VO1 VO2 3.17 4.80 11.52 14.40 11.52 -11.52 14.40 -14.40 -- -- -- -- -- -- -- -- 3.43 5.20 12.48 15.60 12.48 -12.48 15.60 -15.60 Vdc Vdc Vdc Vdc Vdc Vdc Vdc Vdc All LAW005F LAW005A LAW005B LAW005C LAW005BK LAW005CL All -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 0.2 0.5 0.5 0.5 0.5 1.0 1.0 0.2 %VO %VO %VO %VO %VO %VO %VO %VO All All -- -- -- -- -- -- 10 75 mVrms mVp-p External Load Capacitance LAW005F LAW005A LAW005B LAW005C LAW005BK LAW005CL -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 1000 1000 220 150 47 47 F F F F F F Output Current (At IO < IO, min, the modules may exceed output ripple specifications.) LAW005F LAW005A LAW005B LAW005C LAW005BK IO IO IO IO IO1 IO2 IO1 IO2 0.050 0.050 0.024 0.020 0.012 0.012 0.010 0.010 -- -- -- -- -- -- -- -- 1.0 1.0 0.47 0.40 0.23 0.23 0.19 0.19 A A A A A A A A Output Voltage Set Point (VI = 48 V; IO = IO, max; TA = 25 C) LAW005CL Output Voltage (Over all line, load, and temperature conditions until end of life; see Figure 3.) LAW005F LAW005A LAW005B LAW005C LAW005BK LAW005CL Output Regulation: Line (VI = 36 V to 75 V) Load (IO = 25% IO, max) Load (IO = 50% IO, max to IO, max) Temperature (TA = -25 C to +71 C) Output Ripple and Noise Voltage (see Figure 2.): RMS Peak-to-peak (5 Hz to 20 MHz) LAW005CL Output Current-limit Inception (VO = 90% x VO, set) All IO -- 165 -- %IO, max Output Short-circuit Current (duration typ. 8 ms before shutdown; VO 60% VO, nom) All IO -- 300 -- %IO, max Lineage Power 3 LAW005-Series Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input; 5 W Data Sheet April 2008 Electrical Specifications (continued) Table 2. Output Specifications (continued) Parameter Device Symbol Min Typ Max Unit Efficiency (VI, nom; IO = IO, max; TA = 25 C; see Figure 3.) LAW005F LAW005A LAW005B LAW005C LAW005BK LAW005CL 71 74 77 78 77 78 73 78 80 82 80 80 -- -- -- -- -- -- % % % % % % All All -- -- -- -- 1 0.15 -- -- %VO, set ms All All -- -- -- -- 1 0.15 -- -- %VO, set ms Dynamic Response (yIO/yt = 1 A/10 s, VI = VI, nom, TA = 25 C): Load Change from IO = 50% to 75% of IO, max: Peak Deviation Settling Time (VO < 10% peak deviation) Load Change from IO = 50% to 25% of IO, max: Peak Deviation Settling Time (VO < 10% peak deviation) Table 3. Isolation Specifications Parameter Min Typ -- 1000 -- pF 100 -- -- M3/4 Isolation Capacitance Isolation Resistance Max Unit Table 4. General Specifications Parameter Min Typ Max Unit -- 18 (0.64) 20 (0.71) g (oz.) Weight Table 5. Feature Specifications 4 Parameter Device Symbol Min Typ Max Unit Output Overvoltage Protection (clamp) Output Overvoltage Protection (clamp) Output Overvoltage Protection (clamp) Output Overvoltage Protection (clamp) Output Overvoltage Protection (clamp) Output Overvoltage Protection (clamp) LAW005F LAW005A LAW005B LAW005C LAW005BK LAW005CL VO,CLAMP VO,CLAMP VO,CLAMP VO,CLAMP VO,CLAMP VO,CLAMP 4.0 6.4 13.8 16.8 -- -- 4.3 6.8 15 18 -- -- 4.6 7.2 15.6 19.1 -- -- V V V V V V Lineage Power Data Sheet April 2008 LAW005-Series Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input; 5 W Test Configurations Safety Considerations For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL 60950, CSA C22.2 No. 60950-00, and VDE 0805 (IEC60950). TO OSCILLOSCOPE LTEST V I (+) 12 H CS 220 F IMPEDANCE < 0.1 @ 20 C, 100 kHz BATTERY VI (-) 1-0304 Note: Input reflected-ripple current is measured with a simulated source impedance of 12 H. Capacitor Cs offsets possible battery impedance. Current is measured at the input of the module. If the input source is non-SELV (ELV or a hazardous voltage greater than 60 Vdc and less than or equal to 75 Vdc), for the module's output to be considered meeting the requirements of safety extra-low voltage (SELV), all of the following must be true: n n Figure 1. Input Reflected-Ripple Test Setup n COPPER STRIP n VO (+) 0.1 F RESISTIVE LOAD SCOPE VO (-) 1-0305 Note: Use a 0.1 F ceramic capacitor. Scope measurement should be made using a BNC socket. Position the load between 50.8 mm and 76.2 mm (2 in. and 3 in.) from the module. Figure 2. Peak-to-Peak Output Noise Measurement Test Setup V O (+) IO II LOAD SUPPLY V I (-) V O (-) CONTACT RESISTANCE 1-0306 Note: All measurements are taken at the module terminals. When socketing, place Kelvin connections at module terminals to avoid measurement errors due to socket contact resistance. [ V O ( + ) - V O (-) ]I O = ------------------------------------------------- x 100 [ V I ( + ) - V I (-) ]I I One VI pin and one VO pin are to be grounded, or both the input and output pins are to be kept floating. The input pins of the module are not operator accessible. Another SELV reliability test is conducted on the whole system, as required by the safety agencies, on the combination of supply source and the subject module to verify that under a single fault, hazardous voltages do not appear at the module's output. Note: Do not ground either of the input pins of the module without grounding one of the output pins. This may allow a non-SELV voltage to appear between the output pins and ground. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. The input to these units is to be provided with a maximum 5 A normal-blow fuse in the ungrounded lead. CONTACT AND DISTRIBUTION LOSSES V I (+) The input source is to be provided with reinforced insulation from any other hazardous voltages, including the ac mains. Feature Description Output Overvoltage Protection (single output modules only) Output overvoltage protection is not a feature on dual output modules. For single output modules, the output overvoltage protection consists of a Transient Voltage Suppressor (TVS) diode across the output terminals. During an ouput overvoltage fault condition, this diode protection clamps the output within the voltages shown in Table 5 % Figure 3. Output Voltage and Efficiency Measurement Test Setup Lineage Power 5 LAW005-Series Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input; 5 W Data Sheet April 2008 Outline Diagram Dimensions are in millimeters and (inches). Tolerances: x.x mm 0.5 mm (x.xx in. 0.02 in.) x.xx mm 0.25 mm (x.xxx in. 0.010 in.) Top View 31.8(1.25) Pin - + + 20.3 (0.80) IN - LAW005A OUT IN: DC 36-75V 0.25A OUT: DC 5V 1A WHITE DOT Side View 10.2 (0.40) MAX PLASTIC INSULATOR * METAL CASE 10.7 (0.42) 0.4 (0.016) TYP 0.25 (0.01) MIN 3.0 (0.12) MIN 4.6 2.54 (0.18) (0.100) STANDOFF DIAMETER 0.90 (0.036) TYP, 4 PLACES 0.5 x 0.3 (0.020 x 0.012) SOLDER-PLATED BRASS, 10 PLACES Single Duals 2 VI(-) VI(-) 3 VI(-) VI(-) 9 NC Common 10 NC NC 11 NC VO(-) 14 VO(+) VO(+) 15 NC NC 16 VO(-) Common 22 VI(+) VI(+) 23 VI(+) VI(+) No connection. Bottom View 4.6 (0.18) 22.9 (0.900) 2 3 9 10 11 11.0 (0.43) 23 22 15.24 (0.600) 1615 14 15.24 (0.600) 2.54 (0.100) 1-0307-1-0309 Note: Pinouts are numbered to fit in a standard 24-pin DIP footprint. * Note insulation thickness when considering clearance from the PWB traces to the metal case. Lead trim option: 2.8 mm 0.25 mm (0.110 in. 0.010 in.). 6 Lineage Power Data Sheet April 2008 LAW005-Series Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input; 5 W Recommended Hole Pattern Component-side footprint. Dimensions are in millimeters and (inches). 15.24 (0.600) 23 22 20.3 (0.80) 4.6 (0.18) 2.54 (0.100) 1615 14 23 910 11 15.24 (0.600) 22.9 (0.900) 31.8 (1.25) 1-0310 Ordering Information Table 6. Device Codes Input Voltage 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc 48 Vdc Output Voltage 3.3 Vdc 5 Vdc 12 Vdc 15 Vdc 12 Vdc 15 Vdc Output Power 3.3 W 5W 5W 5W 5W 5W Device Code LAW005F LAW005A LAW005B LAW005C LAW005BK LAW005CL Comcode 108070749 108070715 108070723 108070731 108070756 108070764 Optional features may be ordered using the device code suffixes shown below. The feature suffixes are listed numerically in descending order. Please contact your Lineage Power Account Manager or Field Application Engineer for pricing and availability. Table 7. Device Options Option Short pins: 2.8 mm 0.25 mm (0.110 in. 0.010 in.) Lineage Power Device Code Suffix 8 7 LAW005-Series Power Modules; dc-dc Converters: 36 Vdc to 75 Vdc Input; 5 W Data Sheet April 2008 A sia-Pacific Head qu art ers T el: +65 6 41 6 4283 World W ide Headq u arters Lin eag e Po wer Co rp oratio n 30 00 Sk yline D riv e, Mes quite, T X 75149, U SA +1-800-526-7819 (Outs id e U .S.A .: +1- 97 2-2 84 -2626) www.line ag ep ower.co m e-m ail: tech sup port1@ lin ea gep ower.co m Eu ro pe, M id dle-East an d Afric a He ad qu arters T el: +49 8 9 6089 286 Ind ia Head qu arters T el: +91 8 0 28411633 Lineage Power reserves the right to make changes to the produc t(s) or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any s uc h pr oduct(s ) or information. (c) 2008 Lineage Power Corpor ation, (Mesquite, Texas ) All International Rights Res er ved. April 2008 ADS01-045EPS (Replaces ADS01-044EPS)