Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8719 Multi-Conductor - Single-Pair Cable For more Information please call 1-800-Belden1 General Description: 16 AWG stranded (19x29) TC conductors, polyethylene insulation, twisted pair, overall Beldfoil(R) shield (100% coverage), 18 AWG stranded TC drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 1 16 19x29 TC - Tinned Copper Total Number of Conductors: 2 Insulation Insulation Material: Insulation Material Wall Thickness (mm) PE - Polyethylene 0.8128 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape w/Shorting Fold 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 18 Stranded TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.8128 Overall Cable Overall Nominal Diameter: 7.950 mm Pair Pair Color Code Chart: Number Color 1 Black & Clear Pair Lay Length & Direction: Lay Length (mm) Twists (twist/m) Direction 69.850 14.436 Left Hand Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +80C UL Temperature Rating: 80C (UL AWM Style 20253) Bulk Cable Weight: 65.481 Kg/Km Max. Recommended Pulling Tension: 453.716 N Min. Bend Radius/Minor Axis: 82.550 mm Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8719 Multi-Conductor - Single-Pair Cable Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CL2, CM NEC Articles: 800, 725 CEC/C(UL) Specification: CM AWM Specification: UL Style 20253 (600 V 80C) EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading CSA Flame Test: FT1 Suitability Suitability - Indoor: Yes Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 65 Nom. Inductance: Inductance (H/m) 0.6562 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 75.463 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 144.364 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 14.7645 Max. Operating Voltage - UL: Voltage Description 600 V RMS UL AWM Style 20253 300 V RMS UL type CM 150 V RMS UL type CL2 Max. Recommended Current: Description Current 10C Temperature Rise 7 Amps per conductor @ 25C Ambient Page 2 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8719 Multi-Conductor - Single-Pair Cable Put Ups and Colors: Item # Putup Ship Weight Color 8719 060U1000 305 MT 20.865 KG CHROME Notes Item Desc 8719 060U500 152 MT 10.886 KG CHROME 8719 0601000 305 MT 22.226 KG CHROME C 2 #16 LDPE FS PVC 8719 06010000 3,048 MT 195.046 KG CHROME CY 2 #16 LDPE FS PVC 8719 0602000 610 MT 43.545 KG CHROME C 2 #16 LDPE FS PVC 8719 060500 152 MT 11.567 KG CHROME C 2 #16 LDPE FS PVC 8719 0605000 1,524 MT 111.131 KG CHROME C 2 #16 LDPE FS PVC 2 #16 LDPE FS PVC 2 #16 LDPE FS PVC Notes: C = CRATE REEL PUT-UP. Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'. Revision Number: 3 Revision Date: 08-02-2013 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013