1
Lighted Pushbutton Switch A3PJ
Rectangular Type with
18.9 mm ×26.1 mm Button
Back-projected LED offers longer life, wider
viewing, and greater viewing distance
Replaceable LED T-1-3/4 standardized for ease of
maintenance
Two choices of contacts to match load require-
ments: silver and gold
Snap-action offers high reliability
Lamped type also available
Button lockable
LED protected by a current-limiting resistor
Ordering Information
Individually order indicators and switch units.
LED-lighted Type
Indicator Unit*Switch Unit**
Pushbutton Switch
A3Pj-5jjj-jjE
Indicator
M2Pj-5jjj-jjE
* The LED-lighted type has a built-in LED chip (which lights either in color or white).
** The switch unit can be used with both the LED and incandescent lamp.
Pushbutton Switch
A3Pj-7jjj-j
Indicator
M2Pj-7jjj-j
LED Ball-lighted Type
Indicator Unit Switch Unit*
LED
Pushbutton Switch
A3PJ-502j
Indicator
* The Switch unit can be used with either the LED-lighted type, LED ball-lighted type, or incandescent lamp-lighted type pushbutton uni
t
DC-operated
SLL-jjEj
AC-/DC-operated
SLL-jjEACj
Pushbutton Switch
A3PJ-7jjj-j
Indicator
M2PJ-7jjj-j
Back
A3PJ A3PJ
2
Incandescent Lamp-lighted Type
Indicator Unit Switch Unit*
Incandescent Lamp
Pushbutton Switch
A3PJ-501j
Indicator
M2PJ-501j
* The Switch unit can be used with either the LED-lighted type, LED ball-lighted type, or incandescent lamp-lighted type
pushbutton unit.
Standard
SLL-jj
Power-saving
SLL-jjH
Pushbutton Switch
A3PJ-7jjj-j
Indicator
M2PJ-7jjj-j
LED-lighted Type
Switch Units
Function Contact & output form Momentary action Alternate action
Switch indication unit
(
i
t
h
i
d
i
d
i
t
i
Silver alloy contact SPDT A3PJ-7010-1 A3PJ-7020-1
(switching and indicating
f
u
n
c
t
i
o
n
s
)
y
DPDT A3PJ-7030-1 A3PJ-7040-1
f
unc
t
i
ons
)
Gold alloy contact SPDT A3PJ-7050-1 A3PJ-7060-1
y
DPDT A3PJ-7070-1 A3PJ-7080-1
Indicator unit (indicating function only) M2PJ-7010-1
Note: The switch unit is supplied with a black flange and a spring mounting clip.
A3PJ A3PJ
3
Display Screen Units (Transmitted Color)
Screen pattern & color For switch indicator
unit
For indicator unit
Single screen type
(
l
i
d
l
)
White A3PJ-5701-jjEM2PJ-5701-jjE
g
y
p
(solid color) Red A3PJ-5702-jjEM2PJ-5702-jjE
Green A3PJ-5703-jjEM2PJ-5703-jjE
Orange A3PJ-5706-jjEM2PJ-5706-jjE
2-split screen type
(
H
i
t
l
)
White A3PJ-5711-jjEM2PJ-5711-jjE
p
y
p
(Horizontal) White Red A3PJ-5712-jjEM2PJ-5712-jjE
Green A3PJ-5713-jjEM2PJ-5713-jjE
Orange A3PJ-5716-jjEM2PJ-5716-jjE
R
e
d
White A3PJ-5721-jjEM2PJ-5721-jjE
Red Red A3PJ-5722-jjEM2PJ-5722-jjE
Green A3PJ-5723-jjEM2PJ-5723-jjE
Orange A3PJ-5726-jjEM2PJ-5726-jjE
G
White A3PJ-5731-jjEM2PJ-5731-jjE
Green Red A3PJ-5732-jjEM2PJ-5732-jjE
Green A3PJ-5733-jjEM2PJ-5733-jjE
Orange A3PJ-5736-jjEM2PJ-5736-jjE
2-split screen type
(Vertical)
White Refer to the LED ball type
Red
Green
3-split screen type
(Horizontal) a
cb
3-split screen type
(Vertical) c
a
b
4-split screen type da
cb
Note: 1. The display screen unit incorporates a lens, a transparent legend plate, a plunger, a colored plate and LED(s). The split screen type
includes a light baffle in addition to the above items.
2. When placing your order for the display screen unit, fill one of the following rated voltage codes in jjof the part number.
Rated voltage Voltage code
5VDC: 05
12 VDC: 12
24 VDC: 24
3. When placing your order for the lamp type lighted pushbutton switch, refer to the ‘‘Ordering Information-Lamp types” section below.
4. When requiring a projected color type, refer to the LED ball type which is supplied with four color plates (white, red, green, and
orange).
A3PJ A3PJ
4
When placing your order for the lamp type and LED ball type A3PJ, specify the required numbers of the switch units, display screen units, and
lamps or LEDs, according to the following tables.
Lamp types
Switch Units
Function Construction
Contact & output form
Momentary action Alternate action
Switch indication unit
(
i
t
h
i
d
i
d
i
t
i
Silver alloy contact SPDT A3PJ-7010-1 A3PJ-7020-1
(switching and indicating
f
u
n
c
t
i
o
n
s
)
y
DPDT A3PJ-7030-1 A3PJ-7040-1
f
unc
t
i
ons
)
Gold alloy contact SPDT A3PJ-7050-1 A3PJ-7060-1
y
DPDT A3PJ-7070-1 A3PJ-7080-1
Indicator unit (indicating function only) M2PJ-7010-1
Note: The switch unit is supplied with a black flange and a spring mounting clip.
Display Screen Units
Screen pattern For
switch-indicator
unit
For indicator unit
Single screen A3PJ-5011 M2PJ-5011
2-split screen
(Horizontal)
A3PJ-5012 M2PJ-5012
2-split scree
(Vertical)
A3PJ-5013 M2PJ-5013
3-split screen
(Horizontal)
A3PJ-5014 M2PJ-5014
3-split screen
(Vertical)
A3PJ-5015 M2PJ-5015
4-split screen A3PJ-5016 M2PJ-5016
Note: The display screen unit consists of a lens, a legend plate, a
plunger, a lamp holder, 5 colored plates (white, red, green,
blue, and yellow) and light baffle (for other than the single
screen type).
Lamps (Standard)
Operating
voltage
Rated
voltage
Rated
current
Model
5V 6V 200 mA SLL-06
12 V 14 V 80 mA SLL-14
24 V 28 V 40 mA SLL-28
Lamps (Microload)
Operating
voltage
Rated
voltage
Rated
current
Model
5V 6V 100 mA SLL-06H
12 V 14 V 40 mA SLL-14H
24 V 28 V 25 mA SLL-28H
Note: 1. Commercially available 1 W lamps can also be used,
provided the base socket conforms to T-13/4 sizing. For
single screen and 2-split screen types, 2 lamps will be
used. However, for the 3-split and 4-split screen types, 4
special Omron lamps (listed under Microload above) are
required to reduce current draw, and heat output.
2. Note that application of 80% of the rated voltage to the
lamp is advantageous in terms of service life and heat
generation.
3. When a dark current is to be conducted through the
lamps to suppress inrush current, allow 20 to 30% of the
rated current to flow.
Number of Necessary Incandescent Lamps
Model Split Lamp No. of lamps
A3PJ
M
2
P
J
Non-split Standard 2
M2PJ 2-split
(Horizontal)
Power-saving 4
2-split
(Vertical)
3-split
4-split
LED-ball Type
Switch Units
Function Construction
Contact & output form
Momentary action Alternate action
Switch indication unit
(
i
t
h
i
d
i
d
i
t
i
Silver alloy contact SPDT A3PJ-7010-1 A3PJ-7020-1
(switching and indicating
f
u
n
c
t
i
o
n
s
)
y
DPDT A3PJ-7030-1 A3PJ-7040-1
f
unc
t
i
ons
)
Gold alloy contact SPDT A3PJ-7050-1 A3PJ-7060-1
y
DPDT A3PJ-7070-1 A3PJ-7080-1
Indicator unit (indicating function only) M2PJ-7010-1
Note: The switch unit is supplied with a black flange and a spring mounting clip.
A3PJ A3PJ
5
Display Screen Unit (LED ball is Not Built-in.)
Split Screen pattern Pushbutton unit Indicator
Non-split A3PJ-5021 M2PJ-5021
2-split (Horizontal) A3PJ-5022 M2PJ-5022
2-split (Vertical) A3PJ-5023 M2PJ-5023
3-split (Horizontal) A3PJ-5024 M2PJ-5024
3-split (Vertical) A3PJ-5025 M2PJ-5025
4-split A3PJ-5026 M2PJ-5026
LED Ball Ratings
Color White Red Yellow Green
Applicable lens color White Red Yellow Green
Operating voltage 5VDC SLL-05EW SLL-05ER SLL-05EY SLL-05EG
p
g
12 VDC SLL-12EW SLL-12ER SLL-12EY SLL-12EG
24 VDC SLL-24EW SLL-24ER SLL-24EY SLL-24EG
Note: The white LEDs are applicable to projected color.
LED Ball Ratings
Rated voltage current (mA) Operating
voltage range
5VDC 30 mA 5VDC
r5%
6VDC 30 mA 6VDC
r5%
12 VDC 15 mA 12 VDCr5%
24 VDC 12.5 mA 24 VDCr5%
Number of Necessary LED Balls
Model Split Lamp No. of lamps
A3PJ Non-split
2
3
4
l
i
t
LED ball 4
M2PJ
p
2-, 3-, 4-split 4
Specifications
Ratings
Silver Alloy Contacts (for Power Loads)
Rated
l
t
(
V
)
Non-inductive load (A) Inductive load (A)
voltage (V) Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC 50.7 31.3
250 VAC 30.5 20.8
8VDC 5 2 4 3
14 VDC 5 2 4 3
30 VDC 4 2 3 3
125 VDC 0.4 0.05 0.4 0.05
250 VDC 0.2 0.03 0.2 0.03
Note: 1. Inductive load: power factor = 0.4; time constant: 7 ms
2. Lamp load has an inrush current of 10 times the steady-state current.
Motor load has an inrush current of 6 times the steady-state current.
Gold Alloy Contacts (for Very Small Loads)
Switching capacity 0.1 A, 30 VDC/125 VAC (re-
sistive load)
LED Chip Ratings
Rated voltage current (mA) Operating
v
o
l
t
a
g
e
Single
screen type
2-split
screen type
v
o
l
t
a
g
e
range
5VDC 80 40×25V
r5%
12 VDC 40 20×212 Vr5%
24 VDC 20 13×224 Vr5%
A3PJ A3PJ
6
Characteristics
Operating frequency Mechanical: 120 operations/minute max.
Electrical: 30 operations/minute max.
Operating force Momentary action: 600 g max.
Alternate action: 700 g max.
Insulation resistance 100 M:min. (at 500 VDC)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between terminals of same polarity
2,000 VAC, 50/60 Hz for 1 minute between terminals of different polarity, between
current-carrying metal part and ground, and between each terminal and non-current-carrying
metal part
Vibration Malfunction durability: 10 to 55 Hz, 1.5 mm double amplitude
Shock Mechanical durability: 200 m/s2(20 G)
Ambient temperature Operating: --10qCto40
qC
Humidity 35 to 85% RH max.
Life expectancy Mechanical:
Momentary-action type: 1,000,000 operations min.
Alternate-action type: 200,000 operations min.
Electrical action type: 100,000 operations min.
(see note below.)
Weight Approx. 20 g to 24.5 g
Note: With the alternate action type, one operation cycle consists of set and reset actions.
Approved by Standards
UL (File No. E41515)
CSA (File No. LR45258)
Silver contact type: 5 A, 125 VAC
3 A, 250VAC
Gold alloy contact type: 0.1 A, 30 VDC
0.1 A, 125 VAC
A3PJ A3PJ
7
Dimensions
Unless otherwise specified, a tolerance of r0.4 mm applies to all dimensions.
A3PJ (M2PJ) A3PJ (M2PJ) with Seal Cover
A3PJ with Switch Guard
Panel cutout*
Note: When the seal cover is employed, neither barrier
nor switch guard can be attached to the switch unit.
* When the flange mount type switches are arranged in the vertical multiple
mounting style, no switch guard can be used.
When a switch guard is employed, no seal cover can be attached to the
switch unit.
Socket (See Accessories.)
PCB Terminal Dimensions
Bottom view
Mounting Holes (Bottom View)
9.3
52.6
A3PJ A3PJ
8
Panel Cutout
Classification Mounting design Panel cutout Remarks
Flange
mount type
Individual
mounting
(Horizontal)
Panel cutout spacing between
rows of units
Flange
mount type
Multiple
mounting
(Horizontal)
Panel cutout spacing between
r
o
w
s
o
f
u
n
i
t
s
Individual
mounting
(Vertical)
rows of units
Multiple
mounting
(Vertical)
Barrier
mount type
Individual
mounting
(Horizontal)
P
l
t
t
i
b
t
Multiple
mounting
(Horizontal)
Panel cutout spacing between
rows of units
Individual
mounting
(Vertical)
D
o
t
t
e
d
l
i
n
e
i
n
d
i
c
a
t
e
s
t
h
e
p
o
s
i
-
Multiple
mounting
(Vertical)
D
otte
d
l
i
ne
i
n
d
i
cates t
h
e pos
i
-
tion of each mounting barrier.
Note: 1. n: Number of units.
2. Recommended panel thickness: 1 to 5 mm
Terminals/Connections
A3PJ-7010-1, A3PJ-7020-1,
A3PJ-7050-1, A3PJ-7060-1
A3PJ-7030-1, A3PJ-7040-1,
A3PJ-7070-1, A3PJ-7080-1 M2PJ-7010-1
With the single screen type, connect an LED across terminals LC and L2.
(Bottom view) (Bottom view) (Bottom view)
A3PJ A3PJ
9
Assembly/Disassembly
1. Locking/Unlocking Positive Lens Lock Mechanism
2. Mounting Display Screen Unit
With the OMRON logo on the switch unit faced upward, and
the LED contact piece of the display screen unit positioned
upward, align the split on each side of the display screen unit
with the projections inside the switch unit, and push the dis-
play screen unit into the switch unit.
3. Removing/Mounting Lens
4. Mounting Light Baffle (Split Screen Type Only)
While holding the plunger case of the display screen unit, in-
sert the light baffle into the interior groove of the plunger case
from above.
5. Mounting Colored Plate
After mounting the light baffle, place the colored plate on the
plunger case with the dull side of the colored plate faced
downward. Be sure that the projection on the upper surface of
the colored plate faces outward.
6. Mounting Switch Onto Panel
xIndividual Mounting
When the mounting switch unit, push the switch unit into the
panel cutout from front of the mounting panel by holding the
switch unit with the logo mark ‘‘OMRON” faced downward.
Since the mounting panel has some elasticity, the switch unit
snaps into the panel with only a single push.
xMultiple Mounting
When mounting a number of switch units in line on the panel,
use the mounting barriers at both ends of the panel cutout and
insert the spacing barrier in between the two switch units.
Push all the connected switch units together into the panel
cutout while holding the mounting barriers at both ends.
A3PJ A3PJ
10
7. Mounting Flange, Barriers and Replacing Spring
Mounting Clip
Mount each part by pushing it in the direction of the arrow
shown in the corresponding illustration below.
xReplacing Spring Mounting Clip
8. Mounting Seal Cover
After mounting the seal cover onto the flange of the switch
unit, push the switch unit into the panel cutout.
9. Fail-safe Relamping Function
xInsert the assembles display screen unit into the switch unit
while pushing the center of the lens.
xAfter the display screen unit is released, the fail-safe
relamping mechanism is unlocked.
xThe switch will operate normally.
A3PJ A3PJ
11
Construction
With the LED type, an LED is incorporated in the plunger case.
With the lamp type, the lamp holder and plunger case are inde-
pendent units. Insert a T-3/4 lamp in this holder.
A3PJ A3PJ
12
Accessories (Order Separately)
Name Appearance Classification For A3PA Remarks
Flange Flange color Black A3PJ-2001 A black flange is provided to
the switch unit havin
g
the suf-
Light gray A3PJ-2002
t
h
e
s
w
i
t
c
h
u
n
i
t
h
a
v
i
n
g
t
h
e
s
u
f
-
fix ‘‘-1” in its model number.
To the switch unit having the
White A3PJ-2003
T
o
t
h
e
s
w
i
t
c
h
u
n
i
t
h
a
v
i
n
g
t
h
e
suffix ‘‘-2”, a light gray flange
is provided.
Socket Wire-wrap terminal A3PJ-4101 Cannot be used with the sol-
id-state out
p
ut t
y
p
e.
PCB terminal A3PJ-4102
i
d
-
s
t
a
t
e
o
u
t
p
u
t
t
y
p
e
.
Cannot be used with 3-pole
t
y
p
e
Solder terminal A3PJ-4103 type.
Barrier Short-edge barrier Black A3PJ-4001 To prevent malfunctioning and
to improve design image of
t
h
t
i
l
Light gray A3PJ-4002
p
g
g
the mounting panel.
Long-edge barrier Black A3PJ-4004
Light gray A3PJ-4005
Intermediate short bar-
rier
Black A3PJ-4007
e
Light gray A3PJ-4008
Intermediate long barri-
er
Black A3PJ4010
Light gray A3PJ-4011
Switch
Guard
For horizontal mounting (with OMRON logo fac-
ing down)
A3PJ-5050 Can be used by exchanging
with the lens.
C
a
n
n
o
t
b
e
u
s
e
d
w
i
t
h
s
e
a
l
For vertical mounting (with OMRON logo facing
to the right)
A3PJ-5055 Cannot be used with seal
cover.
Seal Cov-
er
--- A3PJ-5060 Cannot be used with barrier
and/or switch guard.
Legend
P
l
a
t
e
Transparent legend plate A3PJ-5202 Transparent legend plate is
s
u
p
p
l
i
e
d
w
i
t
h
s
t
a
n
d
a
r
d
L
E
D
P
l
ate Milk-white legend plate A3PJ-5201 supp
l
i
e
d
w
i
t
h
stan
d
ar
d
L
E
D
indicator unit.
Character
P
l
a
t
e
1 sheet (for 20 switch
i
t
)
Character printed A3PJ-5205 Words printed are ‘‘ON”,
O
F
F
S
T
A
R
T
S
T
O
P
Plate
(Charac-
t
e
rFilm
)
(
units) Non-printed (transpar-
ent film)
A3PJ-5207
p
‘‘OFF”, ‘‘START”, ‘‘STOP”,
‘‘RESET”, ‘‘COOL”, and ‘‘MO-
T
O
R”.
O
t
h
e
r
c
h
a
r
a
c
t
e
r
s
c
a
n
t
e
r
F
i
l
m
)
1 sheet (for 1 switch
i
t
)
Character printed A3PJ-5206
T
O
R
.
O
t
h
e
r
c
h
a
r
a
c
t
e
r
s
c
a
n
be printed by request.
(
unit) Non-printed A3PJ-5208
p
y
q
Long
Mounting
Plate
--- A3PJ-3002 Use when vertically mounting
single (with barrier) or multi-
ple switch units (in standard
mounting style and with barri-
er). Since a short mounting
plate is attached to the switch
unit, replace it with the long
one.
Puller --- A3PJ-5080 ---
A3PJ A3PJ
13
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.