1
CSM_E2EQ_DS_E_5_1
Spatter-resistant Proximity Sensor
E2EQ
Spatter-resistant Fluororesin-
coated Proximity Sensor
Superior spatter resistance.
Long Sensing-distance Models added for sensing
distances up to 15 mm.
Pre-wired Smartclick Connector Models are also
available.
Be sure to read Safety Precautions on
page 6.
Ordering Information
Sensors [Refer to Dimensions on page 7.]
Pre-wired Models
Long Sensing-distance Models
Standard Models
Pre-wired Smartclick Connector Models (M12)
Long Sensing-distance Models
Standard Models
Appearance Sensing distance Output configuration Operation mode Model
M12
DC 2-wire
(no polarity) NO
E2EQ-X4X1 2M
M18 E2EQ-X8X1 2M
M30 E2EQ-X15X1 2M
Shielded
4 mm
8 mm
15 mm
Appearance Sensing distance Output configuration Operation mode Model
M12
DC 2-wire NO
E2EQ-X3D1 2M
M18 E2EQ-X7D1 2M
M30 E2EQ-X10D1 2M
Shielded
3 mm
7 mm
10 mm
Appearance Sensing distance Output configuration Operation mode Model
M12 DC 2-wire
(no polarity)
(3)-(4)
pin arrangement
NO
E2EQ-X4X1-M1TJ 0.3M
M18 E2EQ-X8X1-M1TJ 0.3M
M30 E2EQ-X15X1-M1TJ 0.3M
Shielded
4 mm
8 mm
15 mm
Standard Models Sensing distance Output configuration Operation mode Model
M12
DC 2-wire
(1)-(4)
pin arrangement
NO
E2EQ-X3D1-M1TGJ 0.3M
M18 E2EQ-X7D1-M1TGJ 0.3M
M30 E2EQ-X10D1-M1TGJ 0.3M
Shielded
3 mm
7 mm
10 mm
E2EQ
2
Pre-wired Connector Models (M12)
Long Sensing-distance Models
Standard Models
Accessories (Order Separately)
Sensor I/O Connectors (M12)
(Models with Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.)
[Refer to XS2, XS5.]
Note: Refer to Introduction to Sensor I/O Connectors for details.
Ratings and Specifications
Long Sensing-distance Models
*1. Use the Sensor within the range in which the green indicator is ON.
*2. The response frequency is an average value.
*3. The residual voltage is 5 V. Make sure that the device connected to the Sensor can withstand the residual voltage.
Appearance Sensing distance Output configuration Operation mode Model
M12
DC 2-wire
(3)-(4)
pin arrangement
NO
E2EQ-X4X1-M1J 0.3M
M18 E2EQ-X8X1-M1J 0.3M
M30 E2EQ-X15X1-M1J 0.3M
Standard Models Sensing distance Output configuration Operation mode Model
M12
DC 2-wire
(1)-(4)
pin arrangement
NO
E2EQ-X3D1-M1GJ 0.3M
M18 E2EQ-X7D1-M1GJ 0.3M
M30 E2EQ-X10D1-M1GJ 0.3M
Appearance Cable length Sensor I/O Connector model number Applicable Proximity Sensor model number
2 m XS2F-D421-DC0-A
E2EQ-X@X1-M1J
5 m XS2F-D421-GC0-A
2 m XS2F-D422-DC0-A
5 m XS2F-D422-GC0-A
2 m XS2F-D421-DA0-A
E2EQ-X@D1-M1GJ
5 m XS2F-D421-GA0-A
2 m XS2F-D422-DA0-A
5 m XS2F-D422-GA0-A
2 m XS5F-D421-D80-A E2EQ-X@X1-M1TJ
E2EQ-X@D1-M1TGJ
5 m XS5F-D421-G80-A
Model E2EQ-X4X1
E2EQ-X4X1-M1(T)J
E2EQ-X8X1
E2EQ-X8X1-M1(T)J
E2EQ-X15X1
E2EQ-X15X1-M1(T)J
Item
Sensing distance 4 mm ±10% 8 mm ±10% 15 mm ±10%
Set distance *10 to 3.2 mm 0 to 6.4 mm 0 to 12 mm
Differential travel 15% max. of sensing distance
Standard sensing object Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm
Response frequency *21 kHz 0.5 kHz 0.25 kHz
Control
output
Load current 3 to 100 mA
Residual voltage *35 V max. (Load current: 100 mA, Cable length: 2 m)
Operation mode (with sensing
object approaching) Load ON: NO; For details, refer to the timing charts on page 5.
Protection circuits Load short-circuit protection, Surge suppressor
Ambient temperature range Operating: 25 to 70°C, Storage: 40 to 85°C, (with no icing or condensation)
Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of 40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
±15% max. of sensing distance at 23°C in
the temperature range of 25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Shock resistance Destruction: 1,000m/s2 10 times each in X, Y, and Z directions
Connection method Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
Weight
(packed
state)
Pre-wired Models Approx. 65 g Approx. 140 g Approx. 190 g
Pre-wired
Connector Models Approx. 20 g Approx. 40 g Approx. 90 g
Shielded
4 mm
8 mm
15 mm
Shielded
3 mm
7 mm
10 mm
Straight
L-shape
Straight
L-shape
Smartclick
Connector
Straight
E2EQ
3
Standard Models
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
Common Ratings and Performance
Model E2EQ-X3D1
E2EQ-X3D1-M1(T)GJ
E2EQ-X7D1
E2EQ-X7D1-M1(T)GJ
E2EQ-X10D1
E2EQ-X10D1-M1(T)GJ
Item
Sensing distance 3 mm ±10% 7 mm ±10% 10 mm ±10%
Set distance 0 to 2.4 mm 0 to 5.6 mm 0 to 8 mm
Differential travel 10% max. of sensing distance
Standard sensing object Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm
Response frequency *1 kHz 500 Hz 400 Hz
Control
output
Load current 3 to 100 mA
Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m)
Operation mode (with sensing
object approaching) Load ON: NO; For details, refer to the timing charts on page 5.
Protection circuits Load short-circuit protection, Surge suppressor
Ambient temperature range Operating/Storage: 25 to 70°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Connection method E2EQ-X@D1: Pre-wired Models (Standard cable length: 2 m)
E2EQ-X@D1-M1GJ: Pre-wired Connector Models (Standard cable length: 300mm)
Weight
(packed
state)
Pre-wired Models Approx. 120 g Approx. 160 g Approx. 220 g
Pre-wired
Connector Models Approx. 80 g Approx. 110 g Approx. 190 g
Model E2EQ-X4X1
E2EQ-X4X1-M1(T)J
E2EQ-X3D1
E2EQ-X3D1-M1(T)GJ
E2EQ-X8X1
E2EQ-X8X1-M1(T)J
E2EQ-X7D1
E2EQ-X7D1-M1(T)GJ
E2EQ-X15X1
E2EQ-X15X1-M1(T)J
E2EQ-X10D1
E2EQ-X10D1-M1(T)GJ
Item
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page
4.)
Power supply voltage
(operating voltage range) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current 0.8 mA max.
Indicators Operation indicator (red), Setting indicator (green)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Materials
Case Fluororesin coating (Base material: brass)
Sensing surface Fluororesin
Clamping nuts Fluororesin coating (Base material: brass)
Toothed washer Zinc-plated iron
Accessories Instruction manual
E2EQ
4
Engineering Data (Typical)
Sensing Area
E2EQ-X@X@(-M1(T)J) Shielded Models E2EQ-X@D@(-M1(T)GJ)
Influence of Sensing Object Size and Material
E2EQ-X4X1(-M1(T)J) E2EQ-X8X1(-M1(T)J) E2EQ-X15X1(-M1(T)J)
E2EQ-X3D1(-M1(T)GJ) E2EQ-X7D1(-M1(T)GJ) E2EQ-X10D1(-M1(T)GJ)
Y
X
5101520
18
16
14
12
10
8
6
4
2
0
20151050
E2EQ-X4X
E2EQ-X8X
E2EQ-X15X
Distance X (mm)
Distance Y (mm)
Y
X
2
4
E2EQ-X3D1 E2EQ-X7D1
20161284048121620
6
8
10
E2EQ-X10D1
Distance X (mm)
Distance Y
(mm)
E2EQ-X10D1 Sensing Head
E2EQ-X7D1 Sensing Head
E2EQ-X3D1 Sensing Head
50
5
4
3
2
1
X
353025201510
d ×
d t = 1 mm
Distance X (mm)
Side length of sensing object: d (mm)
Stainless steel
(SUS304)
Iron
Brass
Copper
0 10 20 30 40 50
10
8
6
4
2
X
d ×
d t = 1 mm
Distance X (mm)
Side length of sensing object: d (mm)
Iron
Brass
Copper
Stainless steel
(SUS304)
20100
20
16
12
8
4
X
807060504030
d ×
d t = 1 mm
Side len
g
th of sensin
g
object: d (mm)
Distance X (mm)
Stainless steel
(SUS304)
Iron
Brass
Aluminum
Copper
1050
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
X
3530252015
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Distance X (mm)
Aluminum
Stainless steel
(SUS304)
Iron
Copper
Brass
510150
10
9
8
7
6
5
4
3
2
1
X
20 25 30 35 40 45
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Distance X (mm)
Aluminum
Iron
Copper
Brass
Stainless steel
(SUS304)
20151050
14
12
10
8
6
4
2
X
35 55504030 4525
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Distance X (mm)
Aluminum
Stainless steel
(SUS304)
Iron
Copper
Brass
E2EQ
5
I/O Circuit Diagrams
Long Sensing-distance Models
Standard Models
Residual Output Voltage Leakage Current
E2EQ-X@X@(-M1(T)J) E2EQ-X@D@(-M1(T)GJ) E2EQ-X@D
Model Operation
mode Timing Chart Output circuit
E2EQ-X4X1
E2EQ-X8X1
E2EQ-X15X1
E2EQ-X4X1-M1(T)J
E2EQ-X8X1-M1(T)J
E2EQ-X15X1-M1(T)J
NO
5
4
3
2
1
01 3 5 10 30 50 100
Load current (mA)
Residual output voltage (V)
31
5
4
3
2
1
0
1,000500300
1005030105
Load current (mA)
Residual output voltage (V)
20100
1.5
1.0
0.5
E2EQ-X7D1
4030
E2EQ-X10D1
E2EQ-X3D1
Leakage current (mA)
Power supply voltage (V)
0
80 (TYP)
100
(%)
Sensing
object
Rated
sensing
distance
Stable sensing areaNon-sensing area
Unstable
sensing
area
Set position
ON
OFF
ON
OFF
ON
OFF
Setting indicator
(green)
Operation indicator
(red)
Control output
0 V
+V
4
2
1
3
3
4
Note 1. The load can be connected to either the +V or
0 V side.
Note 2. There is no polarity. Therefore, the brown and
blue lines have no polarity.
Brown
Blue
Proximity
Sensor
main
circuit
Load
Connector Pin Arrangement
Note: Pins 1 and 2 are not used.
Model Operation
mode Timing Chart Output circuit
E2EQ-X3D1
E2EQ-X7D1
E2EQ-X10D1
E2EQ-X3D1-M1(T)GJ
E2EQ-X7D1-M1(T)GJ
E2EQ-X10D1-M1(T)GJ
NO
80 (TYP) 0100(%)
Sensing
object
Rated
sensing
distance
Stable sensing areaNon-sensing area
Unstable
sensing
area
Set position
Proximity Sensor
ON
OFF
ON
OFF
ON
OFF
Setting indicator
(green)
Operation
indicator (red)
Control output
0 V
+V
4
1
42
3
1
Connector Pin Arrangement
Note: Pins 2 and 3 are not used.
Note: The load can be connected to either the +V
or 0 V side.
Load
Brown
Blue
Proximity
Sensor
main
circuit
E2EQ
6
Pre-wired Connector Model Connections
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use this product under ambient conditions that exceed the
ratings.
Design
Influence of Surrounding Metal
When mounting the Sensor within a metal panel, ensure that the
clearances given in the following table are maintained. Failure to
maintain these distances may cause deterioration in the performance
of the Sensor.
Influence of Surrounding Metal (Unit: mm)
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.
Mutual Interference (Unit: mm)
Mounting
Do not tighten the nut with excessive force. A washer must be used
with the nut.
Note: 1. The allowable tightening strength depends on the distance from the
edge of the head, as shown in the following table. (A is the distance
from the edge of the head. B includes the nut on the head side. If the
edge of the nut is in part A, the tightening torque for part A applies
instead.)
2. The following torque assume washers are being used.
Model E2EQ-X@X1-M1(T)J E2EQ-X@D1-M1(T)GJ
Connections
4
3
2
1
4
3
2
1
Main
circuit
Brown
(not used)
Black (+)
Blue ()
Pre-wired Connector
Model
E2EQ-X@X1-M1J
Sensor I/O Connector
XS2F-D42@-@C0-A
4
3
2
1
4
3
2
1Brown (+)
Blue ()
Pre-wired Connector
Model
E2EQ-X@D1-M1GJ
Sensor I/O Connector
XS2F-D42@-@A0-A
Main
circuit
4
3
2
1
4
3
2
1
Main
circuit
Brown (not used)
White (not used)
Black (+)
Blue ()
Pre-wired Connector
Model
E2EQ-X@X1-M1TJ
Sensor I/O Connector
XS5F-D421-@80-A
4
3
2
1
4
3
2
1Brown (+)
White (not used)
Blue (not used)
Black ()
Pre-wired Connector
Model
E2EQ-X@D1-M1TGJ
Sensor I/O Connector
XS5F-D421-@80-A
Main
circuit
WARNING
Precautions for Correct Use
Model Item l d D m n
E2EQ-X4X1(-M1(T)J) 2.4 18 2.4 12 18
E2EQ-X8X1(-M1(T)J) 3.6 27 3.6 24 27
E2EQ-X15X1(-M1(T)J) 64564545
E2EQ-X3D1(-M1(T)GJ)
0
12
0
818
E2EQ-X7D1(-M1(T)GJ) 18 20 27
E2EQ-X10D1(-M1(T)GJ) 30 40 45
l
m
n
mD
d dia.
l
Model Item A B
E2EQ-X4X1(-M1(T)J) 30 20
E2EQ-X8X1(-M1(T)J) 60 35
E2EQ-X15X1(-M1(T)J) 110 90
E2EQ-X3D1(-M1(T)GJ) 30 20
E2EQ-X7D1(-M1(T)GJ) 50 35
E2EQ-X10D1(-M1(T)GJ) 100 70
Torque Part A Part B
Model Dimension
(mm) Torque Torque
E2EQ-X4X1(-M1(T)J)
---
30 N·m
E2EQ-X8X1(-M1(T)J) 70 N·m
E2EQ-X15X1(-M1(T)J) 180 N·m
E2EQ-X3D1(-M1(T)GJ) 24 15 N·m ---
E2EQ-X7D1(-M1(T)GJ) 29
E2EQ-X10D1(-M1(T)GJ) 26 39 N·m 78 N·m
A
B
Part B Part A
Shielded Model
E2EQ
7
Dimensions
Pre-wired Models
Long Sensing-distance Models
Standard Models
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
38 9
2
10
33
17 4
21 dia.
*1
M12 × 1Indicators *2
Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Flame-resistant,
Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm),
Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X4X1
E2EQ-X8X1
43 12
2
10
38
24 4
29 dia.
*1
M18 × 1
*1. 4-dia. vinyl-insulated round cable with 2 conductors
(Flame-resistant, Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
*2. Operation indicator (red), Setting indicator (green)
Indicators *2
Two clamping nuts
Toothed washer
48 12
3
10
43
36 5
42 dia.
*1
M30 × 1.5
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Flame-resistant,
Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. Operation indicator (red), Setting indicator (green)
Indicators *2
Two clamping nuts
Toothed washer
E2EQ-X15X1
38
27.6
24
21 dia.
17 5
M12 × 14
Two toothed washers
Indicators *2 *1
Two clamping nuts (fluororesin coated)
*1. 6-dia. vinyl-insulated round cable with 2 conductors
(Flame-resistant, Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal
conduit).
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X3D1
47
32
29
6
29 dia.
24
M18 × 14
*1
Two toothed washers
Indicators *2
Two clamping nuts (fluororesin coated)
*1. 6-dia. vinyl-insulated round cable with 2 conductors
(Flame-resistant, Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal
conduit).
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X7D1
56
42
38
36
42 dia.
10
*1
M30 × 1.5 5Two toothed washers
Indicators *2
Two clamping nuts (fluororesin coated)
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Flame-resistant,
Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X10D1
E2EQ
8
Pre-wired Connector Models
Long Sensing-distance Models
Standard Models
938
33
10
2
4
17
21 dia.
1* M12 × 1
M12 × 1
Two clamping nuts
Toothed
washer
Indicators *2
*1. 4-dia. vinyl-insulated round cable (Flame-resistant,
Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 300 mm
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X4X1-M1(T)J
2
1243
38
10424
29 dia.
*1
M12 × 1
M18 × 1
*1. 6-dia. vinyl-insulated round cable (Flame-resistant,
Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 300 mm
*2. Operation indicator (red), Setting indicator (green)
Indicators *2
Two clamping nuts
Toothed
washer
E2EQ-X8X1-M1(T)J
36
1248
43
510
3
42 dia.
1*
M12 × 1
M30 × 1.5
*1. 6-dia. vinyl-insulated round cable (Flame-resistant,
Conductor cross section: 0.5 mm2, Insulator
diameter: 1.9 mm), Standard length: 300 mm
*2. Operation indicator (red), Setting indicator (green)
Indicators *2
Two clamping nuts
Toothed
washer
E2EQ-X15X1-M1(T)J
E2EQ-X3D1-M1(T)GJ
38
27.6
24
17
21 dia.
5
M12 × 14
*1
Two toothed washers
Indicators *2
Two clamping nuts (fluororesin coated) M12 × 1
(aluminum)
*1. 6-dia. vinyl-insulated round cable (flame-resistant),
Standard length: 300 mm
*2. Operation indicator (red), Setting indicator (green)
E2EQ-X7D1-M1(T)GJ
47
32
29
24
29 dia.
6
M18 × 14
*1
Indicators *2
Two toothed washers
Two clamping nuts (fluororesin coated)
M12 × 1 (aluminum)
*1. 6-dia. vinyl-insulated round cable (flame-
resistant), Standard length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
E2EQ-X10D1-M1(T)GJ
56
42
38
10
36
42 dia.
M30 × 1.5 5
*1
Two toothed washers
Two clamping nuts (fluororesin coated)
Indicators*2
M12 × 1 (aluminum)
*1. 6-dia. vinyl-insulated round cable
(flame-resistant), Standard
length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
Mounting Hole Dimensions
F
Model E2EQ-X4X@
E2EQ-X3@E2EQ-X8X@
E2EQ-X7@E2EQ-X15X@
E2EQ-X10@
F (mm) 12.5 dia. 18.5 dia. 30.5 dia.
+0.5
0
+0.5
0
+0.5
0
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed
part of all quotes, agreements, purchase orders, acknowledgments, price lists,
catalogs, manuals, brochures and other documents, whether electronic or in
writing, relating to the sale of products or services (collectively, the "Products")
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron
objects to any terms or conditions proposed in Buyer’s purchase order or other
documents which are inconsistent with, or in addition to, these Terms.
2. Prices; Payment Terms. All prices stated are current, subject to change with-
out notice by Omron. Omron reserves the right to increase or decrease prices
on any unshipped portions of outstanding orders. Payments for Products are
due net 30 days unless otherwise stated in the invoice.
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices
sent to Buyer after deducting transportation charges, taxes and duties, and will
be allowed only if (i) the invoice is paid according to Omron’s payment terms
and (ii) Buyer has no past due amounts.
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or
the maximum legal rate, whichever is less, on any balance not paid within the
stated terms.
5. Orders. Omron will accept no order less than $200 net billing.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the impor-
tation or sale of the Products.
7. Taxes. All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon,
imposed directly or indirectly on Omron or required to be collected directly or
indirectly by Omron for the manufacture, production, sale, delivery, importa-
tion, consumption or use of the Products sold hereunder (including customs
duties and sales, excise, use, turnover and license taxes) shall be charged to
and remitted by Buyer to Omron.
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory
to Omron, Omron reserves the right to stop shipments or require satisfactory
security or payment in advance. If Buyer fails to make payment or otherwise
comply with these Terms or any related agreement, Omron may (without liabil-
ity and in addition to other remedies) cancel any unshipped portion of Prod-
ucts sold hereunder and stop any Products in transit until Buyer pays all
amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all
unpaid accounts.
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Omron against all related costs or expenses.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machinery, acts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authority.
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:
a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship
except in “break down” situations.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall
constitute delivery to Buyer;
c. All sales and shipments of Products shall be FOB shipping point (unless oth-
erwise stated in writing by Omron), at which point title and risk of loss shall
pass from Omron to Buyer; provided that Omron shall retain a security inter-
est in the Products until the full purchase price is paid;
d. Delivery and shipping dates are estimates only; and
e. Omron will package Products as it deems proper for protection against nor-
mal handling and extra charges apply to special conditions.
12. Claims. Any claim by Buyer against Omron for shortage or damage to the
Products occurring before delivery to the carrier must be presented in writing
to Omron within 30 days of receipt of shipment and include the original trans-
portation bill signed by the carrier noting that the carrier received the Products
from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the
Products will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Omron (or such other period expressed
in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Omron further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Products or oth-
erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli-
gation hereunder shall be, at Omron’s election, to (i) replace (in the form
originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
the non-complying Product; provided that in no event shall Omron be responsi-
ble for warranty, repair, indemnity or any other claims or expenses regarding
the Products unless Omron’s analysis confirms that the Products were prop-
erly handled, stored, installed and maintained and not subject to contamina-
tion, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Compa-
nies shall not be liable for the suitability or unsuitability or the results from the
use of Products in combination with any electrical or electronic components,
circuits, system assemblies or any other materials or substances or environ-
ments. Any advice, recommendations or information given orally or in writing,
are not to be construed as an amendment or addition to the above warranty.
See http://www.omron247.com or contact your Omron representative for pub-
lished information.
14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual
price of the Product on which liability is asserted.
15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
their employees from and against all liabilities, losses, claims, costs and
expenses (including attorney's fees and expenses) related to any claim, inves-
tigation, litigation or proceeding (whether or not Omron is a party) which arises
or is alleged to arise from Buyer's acts or omissions under these Terms or in
any way with respect to the Products. Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Omron and defend or set-
tle any action brought against such Companies to the extent based on a claim
that any Product made to Buyer specifications infringed intellectual property
rights of another party.
16. Property; Confidentiality. Any intellectual property in the Products is the exclu-
sive property of Omron Companies and Buyer shall not attempt to duplicate it
in any way without the written permission of Omron. Notwithstanding any
charges to Buyer for engineering or tooling, all engineering and tooling shall
remain the exclusive property of Omron. All information and materials supplied
by Omron to Buyer relating to the Products are confidential and proprietary,
and Buyer shall limit distribution thereof to its trusted employees and strictly
prevent disclosure to any third party.
17. Export Controls. Buyer shall comply with all applicable laws, regulations and
licenses regarding (i) export of products or information; (iii) sale of products to
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of
regulated technology or information.
18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
and no course of dealing between Buyer and Omron shall operate as a waiver
of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
without Omron's written consent. (c) Law. These Terms are governed by the
law of the jurisdiction of the home office of the Omron company from which
Buyer is purchasing the Products (without regard to conflict of law princi-
ples). (d) Amendment. These Terms constitute the entire agreement between
Buyer and Omron relating to the Products, and no provision may be changed
or waived unless in writing signed by the parties. (e) Severability
. If any provi-
sion hereof is rendered ineffective or invalid, such provision shall not invalidate
any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
against the amount owing in respect of this invoice. (g) Definitions. As used
herein, “includingmeans “including without limitation”; and “Omron Compa-
nies” (or similar words) mean Omron Corporation and any direct or indirect
subsidiary or affiliate thereof.
Certain Precautions on Specifications and Use
1. Suitability of Use. Omron Companies shall not be responsible for conformity
with any standards, codes or regulations which apply to the combination of the
Product in the Buyer’s application or use of the Product. At Buyers request,
Omron will provide applicable third party certification documents identifying
ratings and limitations of use which apply to the Product. This information by
itself is not sufficient for a complete determination of the suitability of the Prod-
uct in combination with the end product, machine, system, or other application
or use. Buyer shall be solely responsible for determining appropriateness of
the particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases but the following is a
non-exhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Use in consumer products or any use in significant quantities.
(iii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety equip-
ment, and installations subject to separate industry or government regulations.
(iv) Systems, machines and equipment that could present a risk to life or prop-
erty. Please know and observe all prohibitions of use applicable to this Prod-
uct.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-
ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
2. Programmable Products. Omron Companies shall not be responsible for the
user’s programming of a programmable Product, or any consequence thereof.
3. Performance Data. Data presented in Omron Company websites, catalogs
and other materials is provided as a guide for the user in determining suitabil-
ity and does not constitute a warranty. It may represent the result of Omron’s
test conditions, and the user must correlate it to actual application require-
ments. Actual performance is subject to the Omron’s Warranty and Limitations
of Liability.
4. Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our prac-
tice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifica-
tions of the Product may be changed without any notice. When in doubt, spe-
cial part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Omron’s representative at any time
to confirm actual specifications of purchased Product.
5. Errors and Omissions. Information presented by Omron Companies has been
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors or omissions.
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada 416.286.6465 866.986.6766 www.omron247.com
OMRON ELECTRONICS DE MEXICO HEAD OFFICE
México DF 52.
55.59.01.43.00
001.800.556.6766 mela@omron.com
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Apodaca, N.L. 52.81.11.56.99.20 001.800.556.6766 mela@omron.com
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil 55.11.2101.6300 www.omron.com.br
OMRON ARGENTINA • SALES OFFICE
Cono Sur 54.11.4783.5300
OMRON CHILE • SALES OFFICE
Santiago 56.9.9917.3920
OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300
OMRON INDUSTRIAL AUTOMATION • THE AMERICAS HEADQUARTERS
Schaumburg, IL USA 847.843.7900 800.556.6766 www.omron247.com
OMRON EUROpE B.V.
Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands.
Tel: +31 (0) 23 568 13 00
Fax: +31 (0) 23 568 13 88
www.industrial.omron.eu
Cat. No. CSM_E2EQ_DS_E_5_1 06/10 Note: Specifications are subject to change. © 2012 Omron Electronics LLC Printed in U.S.A.