6640A Series Single-Output, 200 W DC Power Supplies, GPIB Data Sheet Speed and accuracy for test optimization * * * * * * Fast, low-noise outputs Analog control of output voltage and current Fan-speed control to minimize acoustic noise Parallel and series connections of multiple units Built-in measurements and advanced programmable features Protection features to ensure DUT safety This series of 200 W linear-regulated DC power supplies is designed to maximize the throughput of DUTs through the manufacturing test process with fast up and down programming time. Valuable assemblies can be destroyed by a minor component failure that can allow a surge of voltage or current to flow to the DUT. Fast protection features, including fast crowbar, mode crossover protection, and the ability to connect the protection circuitry of multiple power supplies can increase production yield. Programming of the DC output and the protection features can be done either from the front panel or using industry standard SCPI commands, via the GPIB. Using the serial link, up to 16 power supplies can be connected through one GPIB address. Test system integration can be further simplified be using the VXIplug&play drivers. The output voltage and current can also be controlled with analog signals. This is helpful for certain types of noisy environments, and also immediate reactions to process changes. Lab bench use is enhanced by the fan speed control, which helps to minimize acoustic noise. Specifications Specifications (at 0 to 55 C unless otherwise specified) 6641A 6642A 6643A 6644A 6645A Number of outputs 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Output voltage 0 to 8 V 0 to 20 V 0 to 35 V 0 to 60 V 0 to 120 V Output current (40C) 0 to 20 A 0 to 10 A 0 to 6 A 0 to 3.5 A 0 to 1.5 A Maximum current (50 C/55 C) 18 A/17 A 9 A/8.5 A 5.4 A/5.1 A 3.2 A/3 A 1.4 A/1.3 A Output ratings Programming accuracy (at 25 C 5 C) Voltage 0.06% + 5 mV 10 mV 15 mV 26 mV 51 mV Current 0.15% + 26 mA 13 mA 6.7 mA 4.1 mA 1.7 mA Ripple and noise from 20 Hz to 20 MHz Voltage rms peak-to-peak Current rms 300 V 300 V 400 V 500 V 700 V 3 mV 3 mV 4 mV 5 mV 7 mV 10 mA 5 mA 3 mA 1.5 mA 1 mA Readback accuracy at 25 C 5 C (percent of reading plus fixed) Voltage 0.07% + 6 mV 15 mV 25 mV 40 mV 80 mV +Current 0.15% + 18 mA 9.1 mA 5 mA 3 mA 1.3 mA -Current 0.35% + 40 mA 20 mA 12 mA 6.8 mA 2.9 mA Load regulation Voltage 1 mV 2 mV 3 mV 4 mV 5 mV Current 1 mA 0.5 mA 0.25 mA 0.25 mA 0.25 mA Voltage 0.5 mV 0.5 mV 1 mV 1 mV 2 mV Current 1 mA 0.5 mA 0.25 mA 0.25 mA 0.25 mA Line regulation Transient response time Less than 100 s for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of the output current rating of the supply Supplemental characteristics (Non-warranted characteristics determined by design and useful in applying the product) 6641A 6642A 6643A 6644A 6645A Average programming resolution Voltage 5 mV 10 mV 15 mV 30 mV Current 6 mA 3 mA 2 mA 1.2 mA 0.5 mA OVP 13 mV 30 mV 54 mV 93 mV 190 mV 160 mV 400 mV 700 mV 1.2 V 2.4 V OVP accuracy 2 2 mV Specifications, continued Specifications (at 0 to 55 C unless otherwise specified) 6641A-J04 6643A-J11 6644A-J09 6645A-J05 6645A-J06 Special order option Special order option Special order option Special order option Special order option Number of outputs 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Output voltage 13 V 40 V 70 V 150 V 170 V Output current (40 C) 15.3 A 5A 3A 1.2 A 1A Maximum current (50 C/55 C) 13.77 A/13 A 4.5 A/4.25 A 2.7 A/2.55 A 1.08 A/1.02 A 0.9 A/0.85 A Output ratings Programming accuracy (at 25 C 5 C) Voltage 0.06% + 8.5 mV 17.5 mV 31 mV 65 mV 74 mV Current 0.15% + 21 mA 6.7 mA 4.1 mA 1.7 mA 1.7 mA Ripple and noise from 20 Hz to 20 MHz Voltage 300 V 450 V 600 V 900 V 1 mV peak-to-peak rms 3 mV 3.5 mV 6 mV 9 mV 10 mV rms 8 mA 53 mA 1.5 mA 1 mA 1 mA Current Readback accuracy at 25 C 5 C (percent of reading plus fixed) Voltage 0.07% + 10 mV 30 mV 47 mV 100 mV 140 mV +Current 0.15% + 15 mA 5 mA 3 mA 1.3 mA 1.3 mA -Current 0.35% + 40 mA 12 mA 6.8 mA 2.9 mA 2.9 mA Load regulation Voltage 1 mV 3 mV 4.5 mV 7 mV 8 mV Current 1 mA 0.25 mA 0.25 mA 0.25 mA 0.25 mA Voltage 0.5 mV 1 mV 1.5 mV 2.5 mV 3 mV Current 1 mA 0.25 mA 0.25 mA 0.25 mA 0.25 mA Line regulation Transient response time Less than 100 s for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of the output current rating of the supply Supplemental characteristics (Non-warranted characteristics determined by design and useful in applying the product) 6641A-J04 6643A-J11 6644A-J09 6645A-J05 6645A-J06 Special order option Special order option Special order option Special order option Special order option Average programming resolution Voltage 3.5 mV 12 mV 1.4 mV 37.5 mV 42.5 mV Current 5 mA 2 mA 1.2 mA 0.5 mA 0.5 mA OVP OVP accuracy 23 mV 62 mV 110 mV 250 mV 285 mV 260 mV 800 mV 1.5 mV 3V 3.4 V 3 Supplemental characteristics for all model numbers DC floating voltage: Output terminals can be floated up to 240 VDC from chassis ground Remote sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load. Command processing time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for the power supplies connected directly to the GPIB Output programming response time: The rise and fall time (10/90% and 90/10%) of the output voltage is less than 15 ms. The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 60 ms. Down programming: An active down programmer sinks approximately 20% of the rated output current Modulation: (Analog programming of output voltage and current) Input Signal: 0 to -5 V Input Impedance: 10 k nominal AC input: (AC input frequency 47 to 63 Hz) Voltage 100 VAC 120 VAC 220 VAC 240 VAC Current 4.4 A 3.8 A 2.2 A 2.0 A InpInput power: 480 VA, 400 W at full load; 60 W at no load GPIB interface capabilities: SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, E1, and C0. IEEE-488.2 and SCPIcompatible command set Software driver: * IVI-COM * VXIplug&play Regulatory compliance: Conforms to UL 1244 and IEC61010-1. Size: 425.5 mm W x 88.1 mm H x 439 mm D (16.75 in x 3.5 in x 17.3 in) Weight: Net, 14.2 kg (31.4 lb); shipping, 16.3 kg (36 lb) Warranty: One year Agilent models: 6641A, 6642A, 6643A, 6644A, 6645A Top 421.7 mm 16.6" 240 VDC Max to + - 425.5 mm 16.75" 6 - 32 x 3/8 Screws { A Thomas & Betts 22-18 ring crimp-on will fit in this area } Terminal screw size: m4 x 0.7 x 8 mm 434.3 mm 17.1" 12.7 mm 0.5" 88.1 mm 3.5" Rear Side Output 4 100 mm 3.93" www.agilent.com www.agilent.com/find/6640 Ordering information Opt 100 Opt 120 Opt 220 Opt 240 87 to 106 VAC, 47 to 63 Hz 104 to 127 VAC, 47 to 63 Hz 191 to 233 VAC, 47 to 63 Hz 209 to 250 VAC, 47 to 63 Hz Opt 0L1 Full documentation on CD-ROM and printed user's and programming guides. CD-ROM includes user's guide, programming guide, service manual, and quick start guide Accessories 1CM002A* Rack mount flange kit 88.1 mm H (2U), 1.75 inch hole spacing, two flange brackets 1CP001A* Rack mount flange and handle kit 88.1 mm H (2U) - two brackets and front handles E3663AC Support rails for Agilent rack cabinets p/n 1494-0060 Accessory slide kit p/n 1252-3698 7-pin analog plug p/n 1252-1488 4-pin digital plug p/n 5080-2148 Serial link cable 2 m (6.6 ft) Application notes 10 Practical Tips You Need to Know About Your Power Products, 5965-8239E 10 Hints for Using Your Power Supply to Decrease Test Time, 5968-6359E Understanding Linear Power Supply Operation (AN1554), 5989-2291EN For more information on Agilent Technologies' products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Agilent Advantage Services is committed to your success throughout your equipment's lifetime. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair and reduce your cost of ownership. You can also use Infoline Web Services to manage equipment and services more effectively. By sharing our measurement and service expertise, we help you create the products that change our world. www.agilent.com/find/advantageservices Agilent Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management Sys System www.agilent.com/quality Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent's measurement expertise and product breadth, combined with channel partner convenience. Americas Canada Brazil Mexico United States (877) 894 4414 (11) 4197 3600 01800 5064 800 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 45 80 12 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany Ireland Israel Italy Netherlands Spain Sweden United Kingdom 49 (0) 7031 464 6333 1890 924 204 972-3-9288-504/544 39 02 92 60 8484 31 (0) 20 547 2111 34 (91) 631 3300 0200-88 22 55 44 (0) 118 927 6201 For other unlisted countries: www.agilent.com/find/contactus Revised: January 6, 2012 Modern Connectivity-Using USB and LAN I/O Converters (AN 1475-1) 5989-0123EN Product specifications and descriptions in this document subject to change without notice. * Support rails required (c) Agilent Technologies, Inc. 2012 Published in USA, February 14, 2012 5990-9304EN