Notes:
1. Main circuit protector terminals are stationary male push-on type: .248 [6.30]
wide x .031 [.787] thick x .474 [12.00] long, or screw type: M4 x .354 [8.99]
wide x .031 [.787] thick x .474 [12.00] long.
2. Auxiliary switch terminals are: .110 [2.79] wide x .020 [0.51]
thick x .343 [8.71] long.
3. Tolerance ± .015 [.38] unless noted. Dimensions in brackets [ ] are millimeters.
[35.13]
1.383
[25.77]
1.015
[26.00]
1.024
[9.58]
.377
C
NO
NC
LINE
LOAD
C
NO
NC
LINE
LOAD
C
[19.68]
.775
[9.37]
.369
[18.52]
.729 MAX.
NO
NC
LINE
LOAD
C
NO
NC
LINE
C-NC = Breaker in
“OFF” position.
Breaker in “ON” or manually
turned “OFF” position.
Breaker in electrically tripped
“OFF” position.
Series with
Auxiliary Switch
Auxiliary Alarm
Switch (IRS4, IRSG4)
Series with Auxiliary Switch
CONFIGURATIONS
Series Trip
The most popular configuration for magnetic protectors
is the series trip where the sensing coil and contacts are in
series with the load being protected. In addition to providing
conventional overcurrent protection, the handle position
conveniently indicates circuit status.
Auxiliary Switch (Applies to Series Trip Only)
This is furnished as an integral part of a series pole in
single or multi-pole assemblies. Isolated electrically from the
protector’s circuit, the switch works in unison with the power
contacts and provides indication at a remote location of the
protector’s on-off status.
Auxiliary switch contacts actuate simultaneously with the
main breaker contacts, and will open regardless of whether
the breaker contacts are opened manually or electrically. For
auxiliary switch ratings below 6Vac or 5Vdc, an auxiliary
switch with gold contacts, designated as REG, is available.
Gold contacts are not recommended for load current above
100 milliamps. An optional auxiliary switch, RS, configuration
allows an alarm or signal to be forwarded only upon electrical
overload, allowing for easier detection of fault circuit.
TYPICAL RESISTANCE / IMPEDANCE
Current Ratings
(Amps)
Series Type (Except delays 40, 50, 60)
DC
(ohms)
AC, 50/60Hz
(ohms)
AC, 400Hz
(ohms)
0.050 427 478 —
0.100 100 103 204
0.250 19 20 34
0.500 4.6 6.3 8.2
0.750 2.04 2.06 3.52
1.00 0.91 0.92 1.86
2.50 0.17 0.19 0.28
5.00 0.045 0.046 0.073
7.50 0.018 0.019 0.037
10.0 0.013 0.014 0.020
15.0 0.0072 0.0073 0.0109
20.0 0.005 0.0051 —
25.0 0.003 0.0035 —
DCR and Impedance values are based on measurements by the voltmeter
ammeter method. Rated current is applied for one hour and at a voltage not
less than 20 volts. Ambient temperature: 25 C; Tolerance: Below 10 amps ±
25%; Above 10 amps ± 50%; *Consult factory for special values and for coil
impedance of delays not shown.
[35.13]
1.383
[25.77]
1.015
[26.00]
1.024
[9.58]
.377
C
NO
NC
LINE
LOAD
C
NO
NC
LINE
LOAD
LINE
LOAD
Series
C
[19.68]
.775
[9.37]
.369
[18.52]
.729 MAX.
NO
NC
[35.13]
1.383
[3.43]
.135
Switch
LOAD
LINE
C
NO
NC
LINE
C-NC = Breaker in
“OFF” position.
Breaker in “ON” or manually
turned “OFF” position.
Breaker in electrically tripped
“OFF” position.
Series with
Auxiliary Switch
Auxiliary Alarm
Switch (IRS4, IRSG4)
Series Trip
Series with Auxiliary Switch
IPA Series - Congurations http://airpax.sensata.com
89