IPA/CPA Series
Magnetic Circuit Protectors
83
84
87
89
90
91
93
95
Introduction
Poles
PC Board Mount
Configurations
Operating Characteristics
Delay Curves
Specifications
Decision Tables
INTRODUCTION
The Airpax™ IPA/CPA hydraulic-magnetic circuit protectors
provide low-cost power switching, reliable circuit protection
and accurate circuit control for equipment in the international
marketplace.
IPA models meet IEC spacing requirements that are mandatory
for equipment which must comply with IEC specifications 601
and 950 and VDE specifications 0804 and 0805. In addition, they
are UL Recognized as supplementary protectors per UL STD.
1077, CSA Certified as supplementary protectors per CSA C 22.2-
No. 235, TUV Approved to VDE 0642 (EN60934), CCC Approved
(pending) and CE Compliant.
Designed using the latest in sensitive hydraulic magnetic
technology, the IPA line adapts itself to many applications and
environments. They’re ideal for data processing and business
machines, medical instrumentation, broadcast equipment,
vending and amusement machines, military applications
and wherever precision operation is required. Temperature
differences which affect fuses and other thermal devices are not
a concern.
One important feature of this protector line is a “trip free” action,
which means the circuit will trip in the presence of an overload
even though the handle is held in the ON position. The delay
mechanism senses the fault and the contacts open.
The IPA is available in configurations including series and series
with auxiliary switch, with a choice of delays and ratings in either
DC, 50/60Hz or 400Hz versions. Single or multi-pole versions
are available, with a variety of pole arrangements to meet your
specifications.
IPA/CPA Series
Hydraulic Magnetic Circuit Protectors
IPA Series - Introduction http://airpax.sensata.com
83
1.260
[32.00]
.640 MAX.
[16.26]
2X 6-32 THREAD
.165 MAX.
[4.19]
.535
[13.59]
1.654
[42.01]
.982
[24.94]
.228
[5.79]
O
N
O
F
F
1.732
[43.99]
.098
[2.49]
60
1.988 MAX.
[50.50]
.635
[16.13]
LINE
SINGLE POLE (ONE HANDLE)
Notes:
1. Tolerance ± .015 [.38] unless noted. Dimensions in brackets [ ] are millimeters.
2. Main circuit breaker terminals are stationary male push-on type: .248 [6.30]
wide x .031 [.787] thick x .474 [12.00] long, or screw type: M4 x .354 [8.99]
wide x .031 [.787] thick x .474 [12.00] long.
.787
[19.99]
1.260
[32.00]
.551
[14.00]
2X .157
[3.99]
Mounting Detail
IPA Series - Poles 84
IPA Series (PCB Mount)
MULTI-POLE CIRCUIT PROTECTORS
Two Pole Protectors
An assembly consisting of two single pole units, having their trip
mechanisms internally coupled and with a single toggle handle,
forms the IPA-11 with quick-connect D.I.N.-style terminals.
Individual poles may differ in ratings, delays and internal
connections. An auxiliary switch may be included in either or both
poles, allowing you to mix SELV and hazardous voltages. Rugged
screw-type terminals can be provided, in which case the
designation would be IPA-66. The IPAH offers a toggle handle for
each pole.
Three Pole Protectors
The three pole construction consists of three single pole units
assembled with an internal mechanical interlock which actuates
Note: Tolerance ± .015 [.38]
unless noted. Dimensions in
Brackets [ ] are millimeters.
1.295 MAX.
[32.89]
O
N
O
F
F
1.935 MAX.
[49.15]
O
N
O
F
F
.630
[16.00]
.630
[16.00]
.630
[16.00]
0.551
Mounting Details
Two Pole Protectors
(one handle)
IPA/CPA
Three Pole Protectors
(one handle)
Two Pole Three Pole
0.551
(Optional: Handle may be
located in Pole 1 instead of
Pole 2)
all units simultaneously. A single toggle handle operates all three
poles for quick and convenient control, or if preferred, a handle
per pole is available. The individual poles need not have identical
characteristics and any series trip pole may have an auxiliary
switch. If screw-type terminals are required, the breaker
designation will be IPA-666 for a three pole version.
Breaker poles are numbered consecutively when viewed from the
terminal side, with the ON position up, starting with Pole #1 on
the left side and proceeding to the right.
Handles
The IPAH two and three pole models are available with a handle
per pole.
IPA Series - Poles http://airpax.sensata.com
85
Note: Tolerance ± .015 [.38]
unless noted. Dimensions in
Brackets [ ] are millimeters.
1.295 MAX.
[32.89]
O
N
O
F
F
1.935 MAX.
[49.15]
O
N
O
F
F
.630
[16.00]
.630
[16.00]
.630
[16.00]
0.551
Mounting Details
Two Pole Protectors
(one handle)
IPA/CPA
Three Pole Protectors
(one handle)
Two Pole Three Pole
0.551
(Optional: Handle may be
located in Pole 1 instead of
Pole 2)
IPA Series - Poles 86
IPA Series (PCB Mount)
[35.99]
1.417
[3.99]
.157
[5.00]
.197
[8.00]
.315
[1.19]
.047
[13.59]
.535
[21.59]
.850
[5.00]
.197
[1.90]
4X Ø.075
[0.80]
.031
[3.51]
.138
[12.50]
.492
[1.20]
.047
[45.49]
1.791
[1.19]
.047
[5.00]
.197
[59.79]
2.354
[0.51]
.020
[0.79]
.031
[3.51]
.138
[1.90]
9X Ø.075 [12.50]
.492
[45.80]
1.803
[59.99]
2.362
[5.00]
.197
[21.59]
.850
[13.59]
.535
[11.71]
.461
[10.31]
.406
[6.10]
.240
HANDLE
CENTER
HANDLE CENTER
[6.25]
.246
[35.99]
1.417
[3.01]
.118
[8.00]
.315
[42.01]
1.654
[45.49]
1.791
[1.19]
.047
[5.00]
.197
[59.79]
2.354
[0.51]
.020
[0.79]
.031
[3.51]
.138
[0.80]
.031
[3.51]
.138
[12.50]
.492
[1.20]
.047
HANDLE CENTER
[1.90]
9X Ø.075
[45.80]
1.803
[59.99]
2.362
[5.00]
.197
[21.59]
.850
[13.59]
.535
[11.71]
.461
[10.31]
.406
[6.10]
.240
[12.50]
.492
[6.25]
.246
Mounting Detail
Mounting Detail
Mounting Detail
(Auxiliary switch is not recommended
with this type mounting.)
O
F
F
O
N
Printed Circuit Board Mounting Terminal Type “S” Printed Circuit Board Mounting Terminal Type “L
Printed Circuit Board Mounting Terminal Type “R
O
F
F
O
N
Note: Tolerance ± .015 [.38] unless noted.
Dimensions in brackets [ ] are millimeters.
PC (PRINTED CIRCUIT) BOARD MOUNTED CIRCUIT PROTECTORS
IPA Series - PC Board Mount http://airpax.sensata.com
87
[35.99]
1.417
[3.99]
.157
[5.00]
.197
[8.00]
.315
[1.19]
.047
[13.59]
.535
[21.59]
.850
[5.00]
.197
[1.90]
4X Ø.075
[0.80]
.031
[3.51]
.138
[12.50]
.492
[1.20]
.047
[45.49]
1.791
[1.19]
.047
[5.00]
.197
[59.79]
2.354
[0.51]
.020
[0.79]
.031
[3.51]
.138
[1.90]
9X Ø.075 [12.50]
.492
[45.80]
1.803
[59.99]
2.362
[5.00]
.197
[21.59]
.850
[13.59]
.535
[11.71]
.461
[10.31]
.406
[6.10]
.240
HANDLE
CENTER
HANDLE CENTER
[6.25]
.246
[35.99]
1.417
[3.01]
.118
[8.00]
.315
[42.01]
1.654
[45.49]
1.791
[1.19]
.047
[5.00]
.197
[59.79]
2.354
[0.51]
.020
[0.79]
.031
[3.51]
.138
[0.80]
.031
[3.51]
.138
[12.50]
.492
[1.20]
.047
HANDLE CENTER
[1.90]
9X Ø.075
[45.80]
1.803
[59.99]
2.362
[5.00]
.197
[21.59]
.850
[13.59]
.535
[11.71]
.461
[10.31]
.406
[6.10]
.240
[12.50]
.492
[6.25]
.246
Mounting Detail
Mounting Detail
Mounting Detail
(Auxiliary switch is not recommended
with this type mounting.)
O
F
F
O
N
Printed Circuit Board Mounting Terminal Type “S”
Printed Circuit Board Mounting Terminal Type “L
Printed Circuit Board Mounting Terminal Type “R”
O
F
F
O
N
Note: Tolerance ± .015 [.38] unless noted.
Dimensions in brackets [ ] are millimeters.
IPA Series - PC Board Mount 88
IPA Series (PCB Mount)
[35.99]
1.417
[3.99]
.157
[5.00]
.197
[8.00]
.315
[1.19]
.047
[13.59]
.535
[21.59]
.850
[5.00]
.197
[1.90]
4X Ø.075
[0.80]
.031
[3.51]
.138
[12.50]
.492
[1.20]
.047
[45.49]
1.791
[1.19]
.047
[5.00]
.197
[59.79]
2.354
[0.51]
.020
[0.79]
.031
[3.51]
.138
[1.90]
9X Ø.075 [12.50]
.492
[45.80]
1.803
[59.99]
2.362
[5.00]
.197
[21.59]
.850
[13.59]
.535
[11.71]
.461
[10.31]
.406
[6.10]
.240
HANDLE
CENTER
HANDLE CENTER
[6.25]
.246
[35.99]
1.417
[3.01]
.118
[8.00]
.315
[42.01]
1.654
[45.49]
1.791
[1.19]
.047
[5.00]
.197
[59.79]
2.354
[0.51]
.020
[0.79]
.031
[3.51]
.138
[0.80]
.031
[3.51]
.138
[12.50]
.492
[1.20]
.047
HANDLE CENTER
[1.90]
9X Ø.075
[45.80]
1.803
[59.99]
2.362
[5.00]
.197
[21.59]
.850
[13.59]
.535
[11.71]
.461
[10.31]
.406
[6.10]
.240
[12.50]
.492
[6.25]
.246
Mounting Detail
Mounting Detail
Mounting Detail
(Auxiliary switch is not recommended
with this type mounting.)
O
F
F
O
N
Printed Circuit Board Mounting Terminal Type “S”
Printed Circuit Board Mounting Terminal Type “L”
Printed Circuit Board Mounting Terminal Type “R”
O
F
F
O
N
Notes:
1. Main circuit protector terminals are stationary male push-on type: .248 [6.30]
wide x .031 [.787] thick x .474 [12.00] long, or screw type: M4 x .354 [8.99]
wide x .031 [.787] thick x .474 [12.00] long.
2. Auxiliary switch terminals are: .110 [2.79] wide x .020 [0.51]
thick x .343 [8.71] long.
3. Tolerance ± .015 [.38] unless noted. Dimensions in brackets [ ] are millimeters.
[35.13]
1.383
[25.77]
1.015
[26.00]
1.024
[9.58]
.377
C
NO
NC
LINE
LOAD
C
NO
NC
LINE
LOAD
LINE
LOAD
Series
C
[19.68]
.775
[9.37]
.369
[18.52]
.729 MAX.
NO
NC
[35.13]
1.383
[3.43]
.135
LINE
LOAD
Switch
LOAD
LINE
C
NO
NC
LINE
C-NC = Breaker in
“OFF” position.
Breaker in “ON” or manually
turned “OFF” position.
Breaker in electrically tripped
“OFF” position.
Series with
Auxiliary Switch
Auxiliary Alarm
Switch (IRS4, IRSG4)
Series Trip
Series with Auxiliary Switch
CONFIGURATIONS
Series Trip
The most popular configuration for magnetic protectors
is the series trip where the sensing coil and contacts are in
series with the load being protected. In addition to providing
conventional overcurrent protection, the handle position
conveniently indicates circuit status.
Auxiliary Switch (Applies to Series Trip Only)
This is furnished as an integral part of a series pole in
single or multi-pole assemblies. Isolated electrically from the
protector’s circuit, the switch works in unison with the power
contacts and provides indication at a remote location of the
protector’s on-off status.
Auxiliary switch contacts actuate simultaneously with the
main breaker contacts, and will open regardless of whether
the breaker contacts are opened manually or electrically. For
auxiliary switch ratings below 6Vac or 5Vdc, an auxiliary
switch with gold contacts, designated as REG, is available.
Gold contacts are not recommended for load current above
100 milliamps. An optional auxiliary switch, RS, configuration
allows an alarm or signal to be forwarded only upon electrical
overload, allowing for easier detection of fault circuit.
TYPICAL RESISTANCE / IMPEDANCE
Current Ratings
(Amps)
Series Type (Except delays 40, 50, 60)
DC
(ohms)
AC, 50/60Hz
(ohms)
AC, 400Hz
(ohms)
0.050 427 478
0.100 100 103 204
0.250 19 20 34
0.500 4.6 6.3 8.2
0.750 2.04 2.06 3.52
1.00 0.91 0.92 1.86
2.50 0.17 0.19 0.28
5.00 0.045 0.046 0.073
7.50 0.018 0.019 0.037
10.0 0.013 0.014 0.020
15.0 0.0072 0.0073 0.0109
20.0 0.005 0.0051
25.0 0.003 0.0035
DCR and Impedance values are based on measurements by the voltmeter
ammeter method. Rated current is applied for one hour and at a voltage not
less than 20 volts. Ambient temperature: 25 C; Tolerance: Below 10 amps ±
25%; Above 10 amps ± 50%; *Consult factory for special values and for coil
impedance of delays not shown.
[35.13]
1.383
[25.77]
1.015
[26.00]
1.024
[9.58]
.377
C
NO
NC
LINE
LOAD
C
NO
NC
LINE
LOAD
LINE
LOAD
Series
C
[19.68]
.775
[9.37]
.369
[18.52]
.729 MAX.
NO
NC
[35.13]
1.383
[3.43]
.135
LINE
LOAD
Switch
LOAD
LINE
C
NO
NC
LINE
C-NC = Breaker in
“OFF” position.
Breaker in “ON” or manually
turned “OFF” position.
Breaker in electrically tripped
“OFF” position.
Series with
Auxiliary Switch
Auxiliary Alarm
Switch (IRS4, IRSG4)
Series Trip
Series with Auxiliary Switch
IPA Series - Congurations http://airpax.sensata.com
89
PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C (VERTICAL MOUNT)
Frequency Delay 100% 125% 150% 200% 400% 600% 800% 1000%
400 Hz
40 No Trip May Trip May Trip .090 Max .060 Max .050 Max .040 Max .035 Max
41 No Trip May Trip .2 to 9 .09 to 3 .02 to .6 .006 to .3 .003 to .2 .003 to .15
42 No Trip May Trip 3 to 80 1 to 25 .06 to 4 .01 to 1.5 .004 to .6 .003 to .3
400 No Trip May Trip 20 to 900 6 to 250 .2 to 45 .01 to 6 .003 to .9 .003 to .5
DC
51* No Trip .500 to 16 .3 to 5 .13 to 1.5 .03 to .2 .005 to .1 .003 to .05 .003 to .025
52* No Trip 7 to 100 3 to 40 .620 to 15 .12 to 2.5 .003 to .5 .003 to .05 .003 to .025
59* No Trip .120 Max .073 Max .038 Max .021 Max .017 Max .017 Max .017 Max
500 No Trip 70 to 800 25 to 300 10 to 100 1.2 to 20 .007 to 5 .004 to .65 .003 to .1
50/60 Hz
61 No Trip .700 to 15 .3 to 4 .1 to 1.3 .02 to .25 .006 to .13 .003 to .07 .003 to .04
62 No Trip 12 to 180 6 to 70 2 to 25 .15 to 3.5 .005 to .3 .004 to .13 .004 to .04
69 No Trip .120 Max .073 Max .038 Max .021 Max .017 Max .017 Max .017 Max
600 No Trip 50 to 800 20 to 300 5.5 to 110 .3 to 17 .004 to .5 .004 to .5 .004 to .1
Notes: All trip times and trip currents are specified with the protector mounted in the normal vertical position at ambient temperature of 25 C.
Breakers do not carry current prior to application of overload.
*CPA type units are available only with 51, 52 and 59 delays.
AGENCY APPROVALS
IPA Series Rated Current (Amps) Interrupting Capacity (Amps)
Max Voltage
Rating Frequency (Hz) Phase Minimum
Poles UL/CSA TÜV UL1077 & CSA TÜV
65 DC 1 .05 to 30 .05 to 25 3000 1000 (Note 1)
80 DC 1 .05 to 20 300
240 50/60 1 & 3 1 25.1 to 30 1000 (Note 1)
250 50/60 1 & 3 1 .05 to 25 .05 to 25 1000 (Note 2) 1000 (Note 1)
250 50/60 1 2 .05 to 30 .05 to 30 1500 1500 (Note 1)
250 400 1 & 3 1 .10 to 15 .05 to 15 1000 1000 (Note 1)
CPA Series Rated Current (Amps) Interrupting Capacity (Amps)
Max Voltage
Rating Frequency (Hz) Phase Minimum
Poles UL/CSA TÜV UL1077 & CSA TÜV
65 DC 1 1 to 30 1000
Notes: (1) with 4 times rated series backup fuse.
(2) with 80A max. series fuse.
IPA Series - Operating Characteristics 90
IPA Series (PCB Mount)
1
900 1000
PERCENT OF RATED CURRENT
.001
10000
.01
100
1000
.1
10
TIME IN SECONDS
0
125
150200 300 400 500 600 700 800
MAY TRIP
DELAY 51
1
900 1000
PERCENT OF RATED CURRENT
.001
10000
.01
100
1000
.1
10
TIME IN SECONDS
0100
125
150 200 300 400 500 600 700 800
MAY TRIP
DELAY 52
1
900 1000
PERCENT OF RATED CURRENT
.001
10000
.01
100
1000
.1
10
TIME IN SECONDS
0
125
150 300 400 500 600 700 800
MAY TRIP
DELAY 500
DELAY 59
900 1000
PERCENT OF RATED CURRENT
.001
10000
.01
100
1000
.1
1
10
TIME IN SECONDS
0100
125
150 200 300 400 500 600 700 800
MAY TRIP
100
100 200
DC Delay Curves (typ)
DELAY CURVES - DC, 50/60HZ, 400HZ
A choice of delays is offered for DC, 50/60Hz and 400Hz
applications.
Delays 40, 59 and 69 provide fast acting, instantaneous
trip and are often used to protect sensitive electronic
equipment (not recommended where a known inrush
exists).
Delays 41, 51 and 61 have a short delay for general
purpose applications.
Delays 42, 52 and 62 are long enough to start certain
types of motors and most transformer and capacitor
loads.
Delays 400, 500 and 600 are long delays for special
motor applications.
IPA Series - Delay Curves http://airpax.sensata.com
91
900 1000
PERCENT OF RATED CURRENT
.001
10000
.01
100
1000
.1
1
10
TIME IN SECONDS
0 100 200 300 400 500 600 700 800
MAY TRIP
900 1000
PERCENT OF RATED CURRENT
.001
10000
.01
100
1000
.1
1
10
TIME IN SECONDS
0 100150 200 300 400 500 600 700 800
MAY TRIP
900 1000
PERCENT OF RATED CURRENT
.001
10000
.01
100
1000
.1
1
10
TIME IN SECONDS
0100 150 200 300 400 500 600 700 800
MAY TRIP
900 1000
PERCENT OF RATED CURRENT
.001
10000
.01
100
1000
.1
1
10
TIME IN SECONDS
0 100 150 200 300 400 500 600 700 800
MAY TRIP
DELAY 40
DELAY 41
DELAY 42
DELAY 400
1
900 1000
PERCENT OF RATED CURRENT
.001
10000
.01
100
1000
.1
10
TIME IN SECONDS
0100
125
150 200 300 400 500 600 700 800
MAY TRIP
DELAY 600
1
900 1000
PERCENT OF RATED CURRENT
.001
10000
.01
100
1000
.1
10
TIME IN SECONDS
0100
125
150 200 300 400 500 600 700 800
MAY TRIP
DELAY 61
900 1000
800
DELAY 69
PERCENT OF RATED CURRENT
.001
10000
.01
100
1000
.1
1
10
TIME IN SECONDS
0 100
125
150 200 300 400 500 600 700
MAY TRIP
1
900 1000
PERCENT OF RATED CURRENT
.001
10000
.01
100
1000
.1
10
TIME IN SECONDS
0100
125
150 200 300 400 500 600 700 800
MAY TRIP
DELAY 62
50/60Hz Delay Curves (typ) 400Hz Delay Curves (typ)
IPA Series - Delay Curves 92
IPA Series (PCB Mount)
SPECIFICATIONS
Trip Free
Will trip open on overload, even when the handle is forcibly held
on or restrained. This prevents operator from damaging the circuit
by holding the handle in the ON position.
Trip Indication
The operating handle moves positively to the OFF position.
Ambient Operation
IPA protectors operate in temperatures between
–40°C and +85°C.
Insulation Resistance
Not less than 100 megohms at 500 volts DC.
Dielectric Strength
IPA protectors withstand 3000Vac, 60Hz for 60 seconds between
all electrically isolated terminals except auxiliary switch terminals
shall withstand 500Vac, 60Hz for REG and REC types.
Endurance
Operating as a switch, the operating life exceeds 10,000
operations, at rated current, at a rate of 6 per minute.
Electrical Characteristics
IPA protectors are rated .050 to 30 amperes 65Vdc; .050 to 30
amperes 240 Vac 50/60Hz; 0.050 to 15 amperes 250Vac, 400Hz.
Poles
One through three poles available.
Construction
Series and series with auxiliary switch available in various delays
and combinations.
Auxiliary and Alarm Switch
When supplied shall be S.P.D.T. configuration with a maximum
rating of 3.0 amperes, 250Vac resistive load. Gold contacts are
rated at .100 amperes, 125Vac resistive load.
Moisture Resistance
Meet all the requirements of MIL-PRF-55629 when tested in
accordance with Method 106 of MIL-STD-202.
Salt Spray (Corrosion)
Meet the requirements of MIL-PRF-55629 when tested in
accordance with Method 101 of MIL-STD-202.
Shock
Circuit protectors shall not trip when tested per MIL-STD-202,
Method 213, Test Condition B with 100% rated current applied to
delayed units and 80% rated current to instantaneous units. Units
with auxiliary switches will withstand 30G max.
Vibration
Circuit protectors shall not trip when vibrated per MIL-STD-202,
Method 201, Test Condition A with 100% rated current applied to
delayed units and 80% rated current to instantaneous units.
IPA Series - Specications http://airpax.sensata.com
93
APPROXIMATE WEIGHT PER POLE
Ounces Grams
1.7 48
RECOMMENDED TORQUE SPECIFICATIONS
Component Torque (in-lbs)
6-32 Mounting Inserts 6 to 8
M3 Mounting Screws 4 to 5
M4 Terminal Screws 10 to 12
Where applicable, mechanical support must be provide to the
terminals when applying torque
INRUSH PULSE TOLERANCE
Delay Pulse Tolerance
61, 62, 600 8 times rated current
61F, 62F, 600F 12 times rated current
Comparison of inrush pulse tolerance is with and without the
inertia delay feature for each of the 50/60 Hz delays. Pulse
tolerance is defined as a single pulse of half sine wave peak
current amplitude of 8 milliseconds duration that will not trip
the circuit protector.
IPA Series - Specications 94
IPA Series (PCB Mount)
Example:
132 4 85 6 7
IPAP -1 -1REC4 - 61- 10.0 - L - 01 - T
Eighth Decision (Optional)
V*
CCC
8
Agency Approval
T
C
First Decision
1
Type
One toggle handle per unit
UL Recognized
One toggle handle per unit
UL Recognized
PC board mount
One toggle handle per pole
UL Recognized
One toggle handle per pole
UL Recognized
PC board mount
One toggle handle per unit
UL Listed per UL489A
One toggle handle per pole
UL Listed per UL489A
I PA
IPAP
IPAH
IPAHP
C PA
CPAH
Third Decision
3
Congurations
Notes: 1. For switch type, eliminate 4th & 5th decision.
2. Switch will be marked with Max. current & voltage.
3. The alarm switch is located in the handle pole for
single handle types and in pole 2 for units with a
handle per pole. The auxilliary switch may be located
in any pole. However the standard location is in pole 2.
4. Switch type with alarm switch must be multi-pole
connected to a pole equipped with either an
overcurrent or overvoltage mechanism.
(Consult factory for further information.)
-1
-1REC4
-1REG4
-1RS4
-1RSG4
Switch only
Series
Series with silver contact
Auxiliary switch
Series with gold contact
Auxiliary switch
Series with silver contact
Alarm switch
Series with gold contact
Alarm switch Sixth Decision (Optional)
6
Mounting & Terminal Type
Metric M3 mounting inserts and
if screw terminals M4.
PC board mounting plate &
terminals, 90 facing left
PC board mounting plate &
terminals, 90 facing right
PC board terminals, rear facing
with front panel insert mount.
Note: Right and Left determined with breaker viewed from
the rear, in normal vertical mounted position. (see pages 70 & 71)
Notes: 1. *25 amperes max rated current for TÜV approval.
2. CCC Approval is pending.
A-
L-
R-
S-
Second Decision
2
Poles
-1
- 11
- 111
-6
-66
-666
Single pole w/ quick connect terminals or PC board if P is used.
Two pole w/ quick connect terminals or PC board if P is used.
Three pole w/ quick connect terminals or PC board if P is used.
Single pole w/ screw terminals
Two pole w/ screw terminals
Three pole w/ screw terminals
Fourth Decision
4
Frequency & Delay
Switch only
400Hz instant trip
400Hz short delay
400Hz long delay
400Hz motor start
DC instant trip*
DC short delay*
DC long delay*
DC motor start
50/60Hz instant trip
50/60Hz short delay
50/60Hz long delay
50/60Hz motor start
Note: For addition of inertial delay, add an “F” to any
delay numeral. (Example: 62F)
*CPA types are only available with DC ratings.
SW
-40
-41
-42
-400
-50
-51
-52
-500
-60
-61
-62
-600
Seventh Decision
Black with I/O markings
7
Handle Color
01
Fifth Decision
5
Rated Current
Use three numbers to specify required
value within ranges described below.
Rating
0.50 to 30.0*
Notes: 1. On multi-pole units, the poles are numbered left to
right when viewed from terminal end.
2. *15 amps maximum at 400Hz
-0
HOW TO ORDER
The ordering code for IPA/CPA protectors may be
determined by following the steps in the decision
tables shown here.
Note:
A The coding given permits a self-assigning part number. Other configurations may require a
factory assigned part number. Typical examples are units with mixed ratings, combinations of
styles or construction. With these, it is suggested that order entry be by description and/or
drawings and a part number will be assigned. Additionally, it is a standard policy to establish a
factory assigned part number wherever a descriptive drawing exits to provide cross reference,
traceability and manufacturing control.
IPA Series - Decision Tables http://airpax.sensata.com
95
Example:
13
2 4 85 6 7
IPAP -1 -1REC4 - 61- 10.0 - L - 01 - T
Eighth Decision (Optional)
TÜV*
CCC
8
Agency Approval
T
C
First Decision
1
Type
One toggle handle per unit
UL Recognized
One toggle handle per unit
UL Recognized
PC board mount
One toggle handle per pole
UL Recognized
One toggle handle per pole
UL Recognized
PC board mount
One toggle handle per unit
UL Listed per UL489A
One toggle handle per pole
UL Listed per UL489A
I PA
IPAP
IPAH
IPAHP
C PA
CPAH
Third Decision
3
Congurations
Notes: 1. For switch type, eliminate 4th & 5th decision.
2. Switch will be marked with Max. current & voltage.
3. The alarm switch is located in the handle pole for
single handle types and in pole 2 for units with a
handle per pole. The auxilliary switch may be located
in any pole. However the standard location is in pole 2.
4. Switch type with alarm switch must be multi-pole
connected to a pole equipped with either an
overcurrent or overvoltage mechanism.
(Consult factory for further information.)
-1
-1REC4
-1REG4
-1RS4
-1RSG4
Switch only
Series
Series with silver contact
Auxiliary switch
Series with gold contact
Auxiliary switch
Series with silver contact
Alarm switch
Series with gold contact
Alarm switch Sixth Decision (Optional)
6
Mounting & Terminal Type
Metric M3 mounting inserts and
if screw terminals M4.
PC board mounting plate &
terminals, 90 facing left
PC board mounting plate &
terminals, 90 facing right
PC board terminals, rear facing
with front panel insert mount.
Note: Right and Left determined with breaker viewed from
the rear, in normal vertical mounted position. (see pages 70 & 71)
Notes: 1. *25 amperes max rated current for TÜV approval.
2. CCC Approval is pending.
A-
L-
R-
S-
Second Decision
2
Poles
-1
- 11
- 111
-6
-66
-666
Single pole w/ quick connect terminals or PC board if P is used.
Two pole w/ quick connect terminals or PC board if P is used.
Three pole w/ quick connect terminals or PC board if P is used.
Single pole w/ screw terminals
Two pole w/ screw terminals
Three pole w/ screw terminals
Fourth Decision
4
Frequency & Delay
Switch only
400Hz instant trip
400Hz short delay
400Hz long delay
400Hz motor start
DC instant trip*
DC short delay*
DC long delay*
DC motor start
50/60Hz instant trip
50/60Hz short delay
50/60Hz long delay
50/60Hz motor start
Note: For addition of inertial delay, add an “F” to any
delay numeral. (Example: 62F)
*CPA types are only available with DC ratings.
SW
-40
-41
-42
-400
-50
-51
-52
-500
-60
-61
-62
-600
Seventh Decision
Black with I/O markings
7
Handle Color
01
Fifth Decision
5
Rated Current
Use three numbers to specify required
value within ranges described below.
Rating
0.50 to 30.0*
Notes: 1. On multi-pole units, the poles are numbered left to
right when viewed from terminal end.
2. *15 amps maximum at 400Hz
-0
IPA Series - Decision Tables 96
IPA Series (PCB Mount)