DS1812 5V EconoReset with Active High Push-Pull Output www.maxim-ic.com FEATURES PIN ASSIGNMENT Automatically restarts a microprocessor after power failure Maintains reset for 150 ms after VCC returns to an in-tolerance condition Reduces need for discrete components Precision temperature-compensated voltage reference and voltage sensor Low-cost TO-92, or space saving surface mount SOT-23 packages available Push-pull active high output Operating temperature -40C to +85C 3 DALLAS DS1812 Econo Reset 1 1 2 3 2 TOP VIEW SOT-23 PACKAGE See Mech. Drawings Section On Website 1 2 3 BOTTOM VIEW TO-92 PACKAGE See Mech. Drawings Section On Website PIN DESCRIPTION TO-92 1 2 3 RST VCC GND Active High Reset Output Power Supply Ground SOT-23 1 2 3 RST VCC GND Active High Reset Output Power Supply Ground DESCRIPTION The DS1812 EconoReset uses a precision temperature reference and comparator circuit to monitor the status of the power supply (VCC). When an out-of-tolerance condition is detected, an internal power-fail signal is generated which forces reset to the active state. When VCC returns to an in-tolerance condition, the reset signal is kept in the active state for approximately 150 ms to allow the power supply and processor to stabilize. 1 of 5 041002 DS1812 OPERATION - POWER MONITOR The DS1812 provides the function of detecting out-of-tolerance power supply conditions and warning a processor-based system of impending power failure. When VCC is detected as out-of-tolerance, the RST signal is asserted. On power-up, RST is kept active for approximately 150 ms after the power supply has reached the selected tolerance. This allows the power supply and microprocessor to stabilize before RST is released. BLOCK DIAGRAM (CMOS OUTPUT) Figure 1 APPLICATION EXAMPLE Figure 2 2 of 5 DS1812 TIMING DIAGRAM: POWER-UP Figure 3 TIMING DIAGRAM: POWER-DOWN Figure 4 3 of 5 DS1812 ABSOLUTE MAXIMUM RATINGS* Voltage on VCC Pin Relative to Ground Voltage on RST Relative to Ground Operating Temperature Storage Temperature Soldering Temperature * -0.5V to +7.0V -0.5V to VCC +0.5V -40C to +85C -55C to +125C 260C for 10 seconds This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operation sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods of time may affect reliability. RECOMMENDED DC OPERATING CONDITIONS PARAMETER SYMBOL MIN Supply Voltage VCC 0.0 DC ELECTRICAL CHARACTERISTICS PARAMETER SYMBOL Output Voltage @ 0-500 mA VOH Output Current @ 2.4 volts IOH Output Current @ 0.4 volts IOL Operating Current VCC < 5.5 ICC VCC Trip Point (DS1812-5) VCCTP VCC Trip Point (DS1812-10) (-40C to +85C) TYP MAX UNITS NOTES 5.5 V 1 (-40C to +85C; VCC=1.2V to 5.5V) MIN VCC -0.5V TYP MAX UNITS NOTES VCC -0.1V V 1 350 mA 2 mA 2 +10 30 40 mA 3 4.50 4.62 4.75 V 1 VCCTP 4.25 4.35 4.49 V 1 VCC Trip Point (DS1812-15) VCCTP 4.00 4.13 4.24 V 1 Output Capacitance COUT 10 pF AC ELECTRICAL CHARACTERISTICS PARAMETER RESET Active Time VCC Detect to RST SYMBOL tRST (-40C to +85C; VCC=1.2V to 5.5V) MIN 100 tRPD TYP 150 MAX 300 UNITS ms 2 5 ms VCC Slew Rate (VCCTP (MAX) to VCCTP (MIN)) tF 300 ms VCC Slew Rate (VCCTP (MIN) to VCCTP (MAX)) tR 0 ns tRPU 100 VCC Detect to RST 4 of 5 150 300 ms NOTES 4 DS1812 NOTES: 1. All voltages are referenced to ground. 2. Measured with VCC 2.7 volts. 3. Measured with RST output open. 4. tR = 5 ms. PART MARKING CODES SOT-23 PACKAGE "A", "B", &"C" represent the device type. 810 DS1810 811 DS1811 812 DS1812 813 DS1813 815 DS1815 816 DS1816 817 DS1817 818 DS1818 "D" represents the device tolerance. A 5% B 10% C 15% D 20% 5 of 5