3 Phase RHP - Hybrid Solid State Contactors 3 Phase Contactor 3 Phase Contactor 40-50 Amp 280/600 VAC 40-50 Amp 120/240 VAC DC Input ENT PATDIN G PEN AC Input Combined SSR and EMR advantages Lifetime >2 million operations @ full load No heat sink required DC logic compatible input Input status LED indicator Wire, lug or quick connect termination DP contactor footprint CE compliant & UL/cUL recognized 100k-cycle UL508 endurance rating OUTPUT SPECIFICATIONS 1 E 20 - 26 VAC, 50/60 Hz 20 VAC 12 VAC 56 VA @ 24 VAC 6.6 VA @ 24 VAC 10 in lb (1.13 Nm) 1 Voltage suffix Operating Voltage (50/60Hz) Maximum Off-State Leakage Current per channel Load Current suffix Maximum Load Current per Phase @ 40C Power terminals / wire range 2 40 50 40 A Resistive Dual quick connect and Binder head screws / AWG#14 - AWG#8 18 in lbs (2.1 Nm) 50 A Resistive Dual quick connect and Box lugs / AWG#14 - AWG#6 25 in lbs (2.9 Nm) Contacts (Double Break ) Part Number Nomenclature SERIES 3 RHP Three Phase Device 12 Load Current 40: 40 Amps 50: 50 Amps 40 D5 Operating Voltage VAC 50/60 Hz Nominal Coil /Control Voltage 12: 120 V 1-phase 24: 240 V 3-phase or 1-phase D5: 5 VDC D12: 12 VDC D24: 24 VDC 28: 280 V 3-phase 60: 600 V 3-phase E: 24 VAC F: 120 VAC G: 220 VAC Three Normally Open -20C to 75C 4 -40C to 100C 16.6 mS @ 60 Hz / 20 mS @ 50 Hz 32 mS @ 60 Hz / 40 mS @ 50 Hz 30 operations per min 1 2 3 4 > 2 Million operations 540 grs (1.19 lb) Specificationts @ 25C unless otherwise noted. See Derating Curves for additional operational conditions. The RHP includes a Solid-State Relay. Therefore, the output is never completely open. The RHP includes an overtemperature protection for the Solid-State Module. Derating Curves 3RHPXX50XX 3RHPXX40XX Load Current, Amps rms Ob 4 4000 VAC 2500 VAC Lifetime @ Rated Load Current, 40C ambient temp, 30 operations/min, Rated Vcontrol Weight (typical) 540 grs (1.19 lb) 50 40 40 A Resistive 50 A Resistive Dual quick connect and Binder Dual quick connect and Box head screws / AWG#14 - AWG#8 lugs / AWG#14 - AWG#6 18 in lbs (2.1 Nm) 25 in lbs (2.9 Nm) Ambient Storage Temperature Range Max. Turn-On Time Max. Turn-Off Time Maximum Number of Operations per Minute Specificationts @ 25C unless otherwise noted. See Derating Curves for additional operational conditions. The RHP includes a Solid-State Relay. Therefore, the output is never completely open. The RHP includes an overtemperature protection for the Solid-State Module. 208 - 240 VAC 0.06 mA @ 240 VAC 1 Ambient Operating Temperature Range > 2 Million operations Lifetime @ Rated Load Current, 40C ambient temp, 30 operations/min, Rated Vcontrol Weight (typical) 3 Contacts (Double Break) 3 16.6 mS @ 60 Hz / 20 mS @ 50 Hz 32 mS @ 60 Hz / 40 mS @ 50 Hz 30 operations per min D24 22 - 27 VDC -27.5 VDC 9.5 VDC 2 VDC 12mA @ 24 VDC 5.31 in lb (0.6 Nm) 24 12 100 - 120 VAC 0.05 mA @ 120 VAC Input to Output Dielectric Isolation Input/Output to Ground Dielectric Isolation -40C to 100C Max. Turn-On Time Max. Turn-Off Time Maximum Number of Operations per Minute 3 GENERAL SPECIFICATIONS -20C to 75C 4 2 Screw torque requirements Three Normally Open 3 Ambient Storage Temperature Range 2 Load Current suffix Maximum Load Current per Phase @ 40C Power terminals / wire range 4000 VAC 2500 VAC D12 10 - 15 VDC -15.5 VDC 9.5 VDC 2 VDC 12mA @ 12 VDC 5.31 in lb (0.6 Nm) 1 Voltage suffix Operating Voltage (50/60Hz) Maximum Off-State Leakage Current per channel 48 - 600 VAC 0.06 mA @ 480 VAC 24 - 280 VAC 0.05 mA @ 240 VAC Input to Output Dielectric Isolation. Input/Output to Ground Dielectric Isolation. 1 OUTPUT SPECIFICATIONS 60 1 Ambient Operating Temperature Range D5 4.5 - 5.5 VDC -5.5 VDC 4.5 VDC 1 VDC 12mA @ 5 VDC 5.31 in lb (0.6 Nm) 55 45 Load Current, Amps rms GENERAL SPECIFICATIONS 1 Control Voltage Suffix Control Voltage Range Max. Reverse Voltage Min. Turn-On Voltage Min. Turn-Off Voltage Input Current Input Connector 100 - 130 VAC, 50/60 Hz 208 - 240 VAC, 50/60 Hz 100 VAC 208 VAC 24 VAC 48 VAC 56 VA @ 120 VAC 56 VA @ 220 VAC 6.6 VA @ 120 VAC 6.6 VA @ 220 VAC 10 in lb (1.13 Nm) 10 in lb (1.13 Nm) 28 3 CONTROL SPECIFICATIONS G so Screw torque requirements F le Control Voltage Suffix Coil Voltage Range Min. Turn-On Voltage Min. Turn-Off Voltage Coil Power Consumption, Inrush Coil Power Consumption, Sealed Coil Terminals te Combined SSR and EMR advantages Lifetime >2 million operations @ full load No heat sink required Input status LED indicator Wire, lug or quick connect termination DP contactor footprint CE compliant & UL/cUL recognized 100k-cycle UL508 endurance rating CONTROL SPECIFICATIONS ENT PATDIN G PEN 40 Power lead size 35 AWG # 6 AWG # 8 30 Safe Operating Area 25 50 45 Power lead size AWG # 6 AWG # 8 40 35 30 Safe Operating Area 25 20 20 25 35 45 55 65 Ambient Temperature, C 75 25 35 45 55 65 Ambient Temperature, C 75 3 Phase RHP - Hybrid Solid State Contactors 5 AC Input/Control Voltage (E, F, G input versions) 1L1 3O Load 4T2 2T1 (For output voltage options 12, 24, 28, 60) 6T3=NC I L1 ~ Neutral 5L3 3L2 1L1 R1 5 DC Input/Control Voltage (D5, D12, D24 input versions) 6 I L1 7 I L3 I L2 NC R2 R1 DC Input/Control Voltage (D5, D12, D24 input versions) IL2 Rated current IL3 Rated current IL2 + IL3 > Rated current Match VLL to voltage suffixes 28 & 60 for options E, F & G and 12 & 24 for options DX. The single phase supply voltage must be wired to terminal 1L1 and 3L2 for proper single phase operation. In applications switching two single phase loads (R1 and R2) where the combined load current exceeds the contactor's rating (40 or 50 Amps) the return/neutral lead must not be wired through the contactor (see above drawing). so IL1 Rated current Ob R2 7 le - + HYBRID SOLID STATE CONTACTOR ~ 1L1 Line 120/240 VAC Single Phase Operating Voltage AC Input/Control Voltage (E, F, G input versions) 3L2 R1 AC Input/Control Voltage (E, F, G input versions) Optional Electrical Connections for Single Phase Applications 6 5L3=NC I L2 IL1 = (IL2 + IL3) Rated current DC Input/Control Voltage (D5, D12, D24 input versions) Neutral 1L1 Neutral I L1 I L1 Line ~ 3L2 DC Input/Control Voltage (D5, D12, D24 input versions) DO NOT apply any AC voltage to contactor coil connections, for DC versions only. 120/240 VAC Single Phase Operating Voltage 120/240 VAC Single Phase Operating Voltage I L3 te VLL I L3 5L3 - + 3L2 Line 6T3 - + 5L3 HYBRID SOLID STATE CONTACTOR ~~ ~ AC Input/Control Voltage (E, F, G input versions) HYBRID SOLID STATE CONTACTOR 3 Phase AC Operating Voltage - + (For output voltage options 24, 28, 60) HYBRID SOLID STATE CONTACTOR Typical Electrical Connection for 3 Phase Applications