NEMIC-LAMBDA JWS 120P SPECIFICATIONS A181-01-01A MODEL ITEMS Nominal Output Voltage Average Output Current Peak Output Current (*1) Average Output Power Peak Output Power (*1) Efficiency (Typ) (*2) Input Voltage Range (*3) Input Current (100/200VAC)(Typ) (*2) Inrush Current(Typ) PFHC Power Factor (100/200VAC)(Typ) (*2) Output Voltage Range Maximum Ripple & Noise 0 ~ +60C (*4) -10 ~ 0C Maximum Line Regulation (*5) Maximum Load Regulation (*6) Temperature Coefficient Over Current Protection (*7) Over Voltage Protection (*8) Hold-up Time (Typ) (*9) Leakage Current (*10) Thermal protection (*11) Remote Sensing Parallel Operation Series Operation Operating Temperature (*12) Operating Humidity Storage Temperature Storage Humidity Cooling Withstand Voltage JWS120P-24 JWS120P-48 24 48 1 5 2.5 2 10 5 3 120 120 4 240 240 5 80 80 6 85 ~ 265VAC (47 ~ 63Hz) 7 1.6/0.8 8 25A at 100VAC, 50A at 200VAC, Ta=25C, Cold Start 9 Built to meet EN61000-3-2 10 0.98/0.92 11 21.6 ~ 26.4 43.2 ~ 52.8 12 240 480 13 360 720 96 192 14 192 384 15 Less than 0.02%/C 16 A 10.2 ~ 5.1 ~ 17 V 27.6 ~ 32.4 55.2 ~ 64.8 18 20ms 19 0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC 20 Built-in 21 Possible 22 23 Possible 24 -10 ~ +60C ( -10 ~ +50C:100%, +60C:60%) 25 30 ~ 90%RH (No dewdrop) 26 -30 ~ +85C 27 10 ~ 95%RH (No dewdrop) 28 Convection Cooling 29 Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA) 30 Output - FG : 500VAC (100mA) for 1min More than 100Mohm at 25C and 70%RH Output - FG... 500VDC 31 Isolation Resistance At no operating, 10-55Hz (Sweep for 1min) 32 Vibration 2G Constant, X, Y, Z 1hour each. Less than 20G 33 Shock (In package) (*13) Built to meet UL1950, CSA950, EN60950,VDE0160. 34 Safety Built to meet DENTORI. Built to meet EN55011/EN55022-A, FCC-ClassA, VCCI-A. 35 Conducted Emission Built to meet EN55011/EN55022-A, FCC-ClassA, VCCI-A. 36 Radiated Emission g 900 37 Weight (Typ.) mm 65 x 92 x 198 ( Refer to Outline Drawing ) 38 Size (WxHxD) *Read instruction manual carefully, before using the power supply unit. =NOTES= *1. Operating time at peak output is less than 10sec.(Duty<=0.5) *2. At 100/200VAC, Ta=25C and average output power. *3. For cases where conformance to various safety specifications (UL, CSA, EN) are required, input voltage range will be 100-240VAC(50/60Hz). *4. Measure with EIAJ RC-9131 probe, Bandwidth of scope :100MHz. *5. 85 - 265VAC , constant load. *6. No load - Average load, constant input voltage. *7. Constant current limit with automatic recovery. *8. OVP circuit will shut down output, manual reset (Line recycle). *9. At 100/200VAC nominal output voltage and average output current. *10. Measured by the each measuring method of UL, CSA, EN and DENTORI(at 60Hz). *11. Power Supply will recover in case of lower the temperature. *12. Ratings - Derating at standard mounting. - Load (%) is percent of average output power or average output current, whichever is greater. - As for other mountings, refer to derating curve (A181-01-02_). *13. As for DENTORI, built to meet at 100VAC. A1810101_Pdf.xls V A A W W % A V mV mV mV mV NEMIC-LAMBDA JWS 120P OUTPUT DERATING A181-01-02 Ta(C) -10 ~+40 45 50 55 60 MOUNTING A 100 100 100 80 60 AVERAGE LOAD(%) MOUNTING B MOUNTING C 100 100 80 80 60 60 - OUTPUT DERATING CURVE AVERAGE LOAD(%) 100 80 MOUNTING A MOUNTING B,C 60 40 20 0 -10 0 10 20 30 40 50 60 70 Ta(C) MOUNTING A (STANDARD MOUNTING ) A1810102Pdf.xls MOUNTING B MOUNTING C PROHIBIT USE PROHIBIT