DC-DC CONVERTERS 40 W Wide Input DC-DC Converters 1
2 YEAR WARRANTY
BXA40 Series
Triple output
•Meets telecom power supply interface standard
ETS300-132-2
•EN60950, CSA950 and UL1950 safety approvals
•EN61000-4-2, -3, -4, -5, -6 immunity compliant
•Fixed frequency operation at 400 kHz
•MTBF in excess of 500,000 hours
•Basic insulation system with 1500 Vdc isolation
•Pin-compatible with NFC40 Series
•Available RoHS compliant
The BXA40-48T05-12-MJ provides 40 Watts of output power, has been conceived as
an applications-specific range of dc-dc converters, specifically addressing
telecommunications, industrial electronics, test equipment, mobile telecommunications
and distributed power applications. The series offers a wide input voltage range, of
36 Vdc to 75 Vdc, and is available with a 5/±12 V triple output. The BXA40 series is
designed to meet ETSI telecoms interface standard ETS300-132-2. With safety
approval to IEC950 and basic insulation, the 48 Vddc model is ideal for
telecommunications applications. Other features include low output ripple, overvoltage
protection, short circuit protection and remote enable.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions EN55022, FCC part 15, Level B
(See Notes 6, 9)
Radiated emissions EN55022, FCC part 15 Level A
ESD air EN61000-4-2, level 3 Perf. criteria 1
ESD contact EN61000-4-2, level 4 Perf. criteria 1
Surge EN61000-4-5, level 3 Perf. criteria 1
Fast transients EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity EN61000-4-3, level 3 Perf. criteria 1
Conducted immunity EN61000-4-6, level 3 Perf. criteria 1
GENERAL SPECIFICATIONS
Efficiency 83%
Isolation voltage Input/output 1500 Vdc
Basic insulation, input/case 1500 Vdc
Switching frequency Fixed 400 kHz (typical)
Approvals and EN60950, UL1950
standards (pending) CSA C22.2 No. 950
Case material Aluminum substrate
with plastic case
Material flammability UL94V-0
Weight 85 g typ. (3.0 oz)
MTBF MIL-HDBK-217F 500,000 hours
Size 2.2 x 2.2 x 0.5 inches
55.9 x 55.9 x 12.7 mm
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Baseplate operating -40 °C to +105 °C
temperature
Non-operating -55 °C to +105 °C
Thermal impedance No air flow, no heatsink 8.5 °C/W
(See Note 8) No air flow, with heatsink 7.2 °C/W
SPECIFICATIONS
File Name: bxa40t.pdf Rev (02): 23 Aug 2005
OUTPUT SPECIFICATIONS
Line regulation Main output ±0.5%
(See Note 2) Auxiliary output ±2.0%
Load regulation Main output ±1.0%
(See Note 3) Auxiliary output ±3.0% typ.,
±5.0% max.
Load cross regulation Main output ±1.0%
(See Note 4) Aux. output ±3.0% typ., ±5.0% max.
Ripple and noise Main output 50 mV pk-pk,
(20 MHz bandwidth) 20 mV rms
Auxiliary output 100 mV pk-pk,
20 mV rms
Temperature coefficient ±0.02%/°C
Overvoltage protection Main output 6.8 V (nom.)
transorbs fitted Auxiliary outputs 16/20 V (nom.)
Short circuit protection Main output 11 A
(See Note 5) Auxiliary output 5 A
Transient response 25% to 100% load 4.0%
Voltage accuracy Main output ±1.0%
Auxiliary output ±3.0%
Minimum load Main output 0.6 A
Auxiliary outputs 0.03 A/0.04 A
INPUT SPECIFICATIONS
Input voltage range 48 Vin nominal 36-75 Vdc
Reverse voltage External fuse (See Note 7)
protection
Max. input rise and 5 V/ms
fall time ETS300-132
Start-up time 30 ms typ.
Remote ON/OFF
Logic compatibility CMOS/TTL
ON Open-circuit
OFF <1 Vdc