DC-DC CONVERTERS 40 W Wide Input DC-DC Converters 1
2 YEAR WARRANTY
BXA40 Series
Triple output
Meets telecom power supply interface standard
ETS300-132-2
EN60950, CSA950 and UL1950 safety approvals
EN61000-4-2, -3, -4, -5, -6 immunity compliant
Fixed frequency operation at 400 kHz
MTBF in excess of 500,000 hours
Basic insulation system with 1500 Vdc isolation
Pin-compatible with NFC40 Series
Available RoHS compliant
The BXA40-48T05-12-MJ provides 40 Watts of output power, has been conceived as
an applications-specific range of dc-dc converters, specifically addressing
telecommunications, industrial electronics, test equipment, mobile telecommunications
and distributed power applications. The series offers a wide input voltage range, of
36 Vdc to 75 Vdc, and is available with a 5/±12 V triple output. The BXA40 series is
designed to meet ETSI telecoms interface standard ETS300-132-2. With safety
approval to IEC950 and basic insulation, the 48 Vddc model is ideal for
telecommunications applications. Other features include low output ripple, overvoltage
protection, short circuit protection and remote enable.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions EN55022, FCC part 15, Level B
(See Notes 6, 9)
Radiated emissions EN55022, FCC part 15 Level A
ESD air EN61000-4-2, level 3 Perf. criteria 1
ESD contact EN61000-4-2, level 4 Perf. criteria 1
Surge EN61000-4-5, level 3 Perf. criteria 1
Fast transients EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity EN61000-4-3, level 3 Perf. criteria 1
Conducted immunity EN61000-4-6, level 3 Perf. criteria 1
GENERAL SPECIFICATIONS
Efficiency 83%
Isolation voltage Input/output 1500 Vdc
Basic insulation, input/case 1500 Vdc
Switching frequency Fixed 400 kHz (typical)
Approvals and EN60950, UL1950
standards (pending) CSA C22.2 No. 950
Case material Aluminum substrate
with plastic case
Material flammability UL94V-0
Weight 85 g typ. (3.0 oz)
MTBF MIL-HDBK-217F 500,000 hours
Size 2.2 x 2.2 x 0.5 inches
55.9 x 55.9 x 12.7 mm
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Baseplate operating -40 °C to +105 °C
temperature
Non-operating -55 °C to +105 °C
Thermal impedance No air flow, no heatsink 8.5 °C/W
(See Note 8) No air flow, with heatsink 7.2 °C/W
SPECIFICATIONS
File Name: bxa40t.pdf Rev (02): 23 Aug 2005
OUTPUT SPECIFICATIONS
Line regulation Main output ±0.5%
(See Note 2) Auxiliary output ±2.0%
Load regulation Main output ±1.0%
(See Note 3) Auxiliary output ±3.0% typ.,
±5.0% max.
Load cross regulation Main output ±1.0%
(See Note 4) Aux. output ±3.0% typ., ±5.0% max.
Ripple and noise Main output 50 mV pk-pk,
(20 MHz bandwidth) 20 mV rms
Auxiliary output 100 mV pk-pk,
20 mV rms
Temperature coefficient ±0.02%/°C
Overvoltage protection Main output 6.8 V (nom.)
transorbs fitted Auxiliary outputs 16/20 V (nom.)
Short circuit protection Main output 11 A
(See Note 5) Auxiliary output 5 A
Transient response 25% to 100% load 4.0%
Voltage accuracy Main output ±1.0%
Auxiliary output ±3.0%
Minimum load Main output 0.6 A
Auxiliary outputs 0.03 A/0.04 A
INPUT SPECIFICATIONS
Input voltage range 48 Vin nominal 36-75 Vdc
Reverse voltage External fuse (See Note 7)
protection
Max. input rise and 5 V/ms
fall time ETS300-132
Start-up time 30 ms typ.
Remote ON/OFF
Logic compatibility CMOS/TTL
ON Open-circuit
OFF <1 Vdc
Datasheet © Artesyn Technologies
®
2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
NNootteess
1Nominal line, at no load.
2Nominal line to high line, nominal line to low line.
3Load regulation:
Main output (V1): 25 to 100% with 25% to 100% balanced on auxiliaries.
Auxiliary outputs (V2 and V3): 25% to 100% balanced on all outputs.
4Cross regulation:
Main output 100% load, auxiliary 100%, other auxiliary 25% to 100%.
Auxiliary outputs (V2 and V3): main output 100% load, auxiliary 100%,
other auxiliary 25% to 100% or main output 25%, auxiliary 25%, other
auxiliary 25% to 100%.
5Short circuit protection, ≤ 1 minute on auxiliary outputs.
6For EMI compliance to EN55022 level B please consult factory for details.
For EMI compliance to EN55022 level A, refer to BXA40 Design Note 101.
7Reverse voltage protection, refer to BXA40 Design Note 101.
8The maximum operating ambient temperature, without derating depends
on internal power dissipation and module efficiency and cooling method.
Download BXA40 Design Note 101 which provides detailed thermal
calculations and design-in hints from the Artesyn website.
9It is suggested that an external filter capacitor be used. A 4 µF (or greater)
film capacitor such as: ITW Paktron Capstick series, part number
405K100CS4 4 µF/100 V is recommended, if filtering is not used. See
BXA40 Design Note 101.
10 The unit with the suffix ‘-M’ at the end of the model number is offered as
standard with metric threaded inserts (M3). To order a unit with imperial
threaded inserts (4-40 UNC) please remove the suffix ‘-M’ from the model
number. These inserts are used for bolting the unit to a
PCB and/or fixing heatsinks.
11 The ‘J’ suffix indicates that these parts are Pb-free
(RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free)
compliant versions may be available on special request,
please contact your local sales representative for
details.
12 NOTICE: Some models do not support all options.
Please contact your local Artesyn representative or use
the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to
find a suitable alternative.
BXA40 Series
Triple output
DC-DC CONVERTERS 40 W Wide Input DC-DC Converters 2
Please consult our website for the following items: Design Note www.artesyn.com
File Name: bxa40t.pdf Rev (02): 23 Aug 2005
INPUT OUTPUT OUTPUT INPUT TYPICAL MODEL NUMBER (10,11,12)
VOLTAGE VOLTAGE CURRENT (MAX.) CURRENT (1) EFFICIENCY
36-75 Vdc 5 V/±12 V 6 A/±0.4 A 30 mA 83% BXA40-48T05-12-MJ
PIN CONNECTIONS
PIN NUMBER TRIPLE OUTPUT
1 + Input
2 – Input
3 Control
4 + Output (V2)
5 Common
6 - Output (V3)
7 + Output (V1)
8 - Output (V1)
9 No Connection
BOTTOM VIEW
ALL DIMENSIONS IN INCHES (mm)
0.3
(7.62)
0.019
(0.50)
0.50
(12.70)
0.15
(3.90)
321
98 76 5 4
2.20 ±0.02
(
5
5
.
9
0 ±0.50
)
1.90
(
4
8
.
2
6
)
1.80
(
4
5
.
7
2
)
0.15
(
3
.
8
2
)
0.05
(
1
.
2
7
)
0.2
(5.08)
0.1
(2.54)
0.6
(15.24)
0.8
(20.32) 0.5
(12.70)
0.2
(5.08)
0.60
(15.24)
1.25
(31.76)
1.90
(48.26)
0.15
(3.82)
0.256 (6.50) Diameter
Stand-off (4 Places)
Metric (Suffix '-M'):
M3 Tap Thru. 4 places or
Imperial (No '-M' suffix) 4-
40 UNC (Optional)
0.043 ±0.003(1.02 ±0.05)
Diameter Typ.
TOLERANCE : ± 0.004 (0.1)
(Unless otherwise specified)
2.20 ±0.02
(
5
5
.
9
0 ±0.50
)
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 14501-3336-7009
Licence No. 6296
UL1950 File No. E174104
CSA C22.2 No. 950 File No. LR41062C