PGFI Series 40, 50 & 60 Amp Portable Series (Cord) ELCI INTRODUCTION The LineGardTM 40, 50 and 60 Amp Portable Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. These devices are designed for industrial and trade applications such as welders, pumps, motors and generators and come standard with selectable key switching for fault level threshold, power on and reset type (automatic vs. manual) settings. As configured the device has three fault threshold settings of 6mA, 10mA and 30mA, with all engineered trip times of 25mS or less. These units come standard with a 6' primary cord and a 6' secondary cord length with flying leads for field configuring. Integrated NEMA or IEC 309 wiring devices are also available as factory customs. The enclosure is configured with floor mount feet but is additionally supplied with wall or surface mounted feet for more permanent installations. All units are MADE IN THE USA and are UL 1053 Compliant. FEATURES Specifications Rated Supply Voltage * Power and fault status indicators Rated Current * * * * Double insulated user interface UL1053 compliant Chemical and UV resistant enclosure 40, 50 and 60 amp configurations in 1O 120 VAC, 1O 240 VAC, 1O 208 VAC, 1O 277 VAC, 120/240 VAC, 3O 240 VAC, 3O 208 VAC, 3O 277 (Available with or without neutral), 3O 480 VAC, 3O 600 VAC * Fault level key switch - max. trip threshold 6mA, 10mA, and 30mA * Surge protection optional * NEMA 4X wet location rated (indoor / outdoor) Field selectable threshold @ 6mA, 10mA and 30mA Phase Single, dual and three phase 1 Reset Type Response Time Operating Temperature Operating Voltage Range * Automatic or manual reset key switch 40 thru 60 Amps or rating of wiring device and/or cable Trip Level Operating Frequency 1 120 VAC 1O to 600 VAC 3O Let-Go Voltage Open Neutral Protection Grounded Neutral Protection 60 Hz Automatic or Manual 25mS max -35C to 66C 85% to 110% of rated VAC 60% of supply voltage Trips upon loss of neutral Trips if ground and neutral touch at load side 1. Manual configuration should be specified if automatic start-up after power restoration of circuit power creates an unsafe condition. 278 PGFI Series - 40, 50, 60 Amp Portable (Cord) Series http://airpax.sensata.com/ Confined Space Construction Sites Application Opportunities: (NEC 590.6) Commercial Garages (NEC 511.12) Outdoor Signs (NEC 600.10) Fountains & Water Displays (NEC 680.58) Spa & Hot Tubs (NEC 680.40) Marinas & Boat Yards Electrical wet locations Power generators Agricultural equipment Outdoor electrical equipment Cement cutting equipment Portable electric heaters Submersible pumps Pipeline heaters Automotive garages Industrial part washers Outdoor signage De-icing equipment (roof heaters) OSHA 29 CFR 1926.404 (b)(1)(ii), OSHA 29 CFR 1926.405 (a)(2)(ii)(G) (NEC 555.3) Ground Fault / Equipment Leakage RELATED CODES DECISION TABLES PGFI - 1 5 4 5 N 1 Product Type 2 Voltage 6 Connectors N Flying leads 3 Ampacity 4 Power-up 5 Secondary cord 4 5 6' Black, SEOOW 1 120 VAC 1O 2 240 VAC 1O 4 40 amps 5 480 VAC 3O 6 600 VAC 3O 5 50 amps 7 240 VAC 3O 8 208 VAC 3O 6 60 amps 9 208 VAC 1O B 277 VAC 3O C 120/240 VAC D 277 VAC 1O Key Switch Auto / Manual Contact Sensata for custom integrated connectors http://airpax.sensata.com/ PGFI Series - 40, 50, 60 Amp Portable (Cord) Series 279