Pressure ranges from 0 to … psi (gage) 100 150 200 300 600 1000 2000 3000 6000 9000 10000
Proof pressure psi (gage) 290 290 465 725 1160 1740 4640 5540 8700 13050 13050
Burst pressure psi (gage) 435 435 695 1085 1740 2610 6960 7250 11600 17400 17400
Output Signal
Operating supply voltage
Power consumption
Load
Overvoltage protection
Short-circuit proofness
Reverse polarity protection
Current Output Voltage Output
Connector PIN 1 / A PIN 4
M12 4-pole Vsup GND
Packard Metri-Pack 150 Iout …
Response time
Reference conditions to EN 61298-1
Accuracy *)
Non-linearity **)
Non-repeatability
1-year stability
Medium
Environmental
Storage
TC zero
TC span
UL
RoHS
CE
Vibration resistance
Shock resistance
Electrical connector
Ingress protection
er IEC 60 529
Weight
Media All class II fluids and gases compatible with stainless steel 304 (1.4301)
appr. 50 gram (sensor without mating connector)
Accuracy
IEC 60068-2-64 (RANDOM) 20 PSD
Unit shall be supplied by a power supply with double/reinforced insulation (SELV) and limited energy in accordance to UL/EN/IEC 61010-1 or LPS in accordance
to UL/EN/IEC 60950-1 or class 2 per UL1310/UL1585 (NEC or CEC). The power supply shall be approved for usage above 2000m if the pressure sensor is used in
this enviroment. For indoor and outdoor use, not exposed to direct sunlight.
IP67IP67 / IP69K (with special mating connector)
-30 °C to +100 °C (depending on electrical connector)
-30 °C to +100 °C (depending on electrical connector)
Temperature coefficients
0.2 % of span / 10 K within temperature range 0 °C to +80 °C
0.2 % of span / 10 K within temperature range 0 °C to +80 °C
Conformity
PIN 2 / B
GND Vsup Vout
14 - 30 VDC
чϲϬϬŵt
min. 33 VDC
Individual customized calibration on request.
min. 33 VDC min. 6 VDC
Electrical
4 - 20 mA 0.5 - 4.5 VDC ratiometric 0 - 10 VDC
8 - 30 VDC 5 VDC ± 5 %
чϲϬϬŵt чϮϱŵt
Packard
Metri-Pack 150 - 3 pole
M12 - 4 pole
Yes *¹)
0.2 % of span
*) Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in
vertical mounting position with pressure port down
**) BFSL according to IEC 61298-2
Temperatures
-30 °C to +120 °C
чϮŵƐŵĂdžƚŽϲϯйŽĨĨƵůůƐĐĂůĞƉƌĞƐƐƵƌĞǁŝƚŚƐƚĞƉĐŚĂŶŐĞŽŶŝŶƉƵƚ
чϬϱйŽĨƐƉĂŶ
0.2 % of span
0.1 % of span
not applicable
PIN 2 / B PIN 3 / C
Yes *¹)
Yes *²)
Standard(s) for Safety: Electrical Equipment for Measurement, Control and Laboratory Use - UL 61010-1
Pin assignment
Yes *²) Yes *²)
*¹) for min. 3 intervals at 5 minutes each at max. rated supply voltage
*²) for min. 10 seconds on assigned pins at max. rated supply voltage
Customized versions on request - contact factory for details.
PIN 4
…
…
PIN 3 / C
According to 2002/95/EC RoHS Directive
Pressure equipment directive 97/23/EC
EMC directive 2004/108/EEC, EN 61 326 Emission (Group 1, Class B)
and Immunity (industrial locations)
25 g minimum according to EN 60068-2-27
Vsup …
Vsup … Vout…Iout
PIN 1 / A
Vsup െ8 VDC
0,02 A π 4.7 kπ 4.7 kπ
Potsdamer Str. 14, 32423 Minden, Germany
Tel: +49 571 3859-0 - Fax: +49 571 3859-119
Email: info@kavlico.de
www.kavlico.com
235 E. Main St., Suite 102A, Northville, MI 48167, USA
Tel: +1 (248) 465-0815 - Fax: +1 (248) 465-0810
Email: pressure.sensors@kavlico.com
Technical Specifi cations