TECHNICAL DATA
HUMIREL HPC055 Rev0 June 2004 HTS2030SMD
1
TEMPERATURE AND RELATIVE HUMIDITY SENSOR HTS2030SMD
Meets RoHS regulations
Based on a unique capacitive cell for humidity measurement and a Negative
Temperature Coefficient (NTC) thermistor for temperature measurement, this dual purpose
relative humidity / temperature miniaturized sensor is designed for high volume, cost
sensitive applications with tight space constraints. It is useful in all applications where
dew point, absolute humidity measurements or humidity compensation are required.
MAIN FEATURES
Miniature Surface mount SMD package.
Lead free components.
Full interchangeability with no calibration required in standard conditions.
Instantaneous desaturation after long periods in saturation phase.
Compatible with automatized assembly processes, including Pb free
wave soldering and reflow processes (1)
High reliability and long term stability.
Patented solid polymer structure.
Suitable for linear voltage or frequency output circuitry.
Fast response time and very low temperature coefficient.
Part may be washed with distilled water.
Individual marking for compliance to stringent traceability requirements.
(1) soldering temperature profiles available on request / contact us at application@humirel.com
MAXIMUM RATINGS Operating Range
0
10
20
30
40
50
60
70
80
90
100
-60 -40 -20 0 20 40 60 80 100 120 140 160
Temperature in °C
Relative Humidity in % RH
Ratings Symbol Value Unit
Operating Temperature Ta -60 to 140 °C
Storage Temperature Tstg -60 to 140 °C
Supply Voltage (Peak) Vs 10 Vac
Humidity Operating Range RH 0 to 100 % RH
CHARACTERISTICS
Humidity sensor (Ta = 25°C, measurement frequency @ 10kHz unless otherwise no ted)
Characteristics Symbol Min. Typ. Max. Unit.
Humidity measuring range RH 1 99 %RH
Supply voltage Vs 10 V
Nominal capacitance @ 55% RH* C 177 180 183 pF
Temperature coefficient Tcc 0.01 pF/°C
Averaged Sensitivity from 33% to 75% RH C /% RH 0.31 pF/% RH
Leakage current (Vcc = 5 Volts) I 1 nA
Recovery time after 150 hours of condensation tr 10 s
Humidity Hysteresis +/-1 %RH
Long term stability τ +/-0.5 %RH/yr
Time constant (33 to 80 % RH, still air @ 63%) ta 3 5 s
Deviation to typical response curve (10% to 90%) RH) +/-2 %RH
*tighter specification available on request
TECHNICAL DATA
HUMIREL HPC055 Rev0 June 2004 HTS2030SMD
2
TYPICAL RESPONSE IN HUMIDITY
Polynomial response of HTS2030SMD:
C (pF)=C@55 %*( 3.903 10-8 *RH3-8.294 10-6 *RH2+2.188 10-3 *RH+0.898)
Typical response look-up table (Polynomial Reference curve) “10kHz/1V
RH (%) 0 5 10 15 20 25 30 35 40 45 50
Cp (pF) 161.6 163.6 165.4 167.2 169.0 170.7 172.3 173.9 175.5 177.0 178.5
RH (%) 55 60 65 70 75 80 85 90 95 100
Cp (pF) 180 181.4 182.9 184.3 185.7 187.2 188.6 190.1 191.6 193.1
160
165
170
175
180
185
190
195
0 102030405060708090100
%RH
Capacitance (pF)
Reversed Polynomial response of HTS2030SMD:
RH (%) = -3.4656 10+3 *X3+1.0732 10+4 *X2-1.0457 10+4 *X+3.2459 10+3
With X=C(read) / C@55%RH
CHARACTERISTICS
Temperature sensor
Characteristics Symbol Min. Typ Max. Unit.
Nominal resistance @ 25°C 10 k
Beta value : B25/100 B 3600 3730 3800
Temperature measuring range Ta -60 140 °C
Nominal Resistance Toleranceat 25°C Rn 2 3 %
B value tolerance B 3 %
Response Time τ 10 s
TYPICAL TEMPERATURE OUTPUT
TECHNICAL DATA
HUMIREL HPC055 Rev0 June 2004 HTS2030SMD
3
Temp °C Resistance
(Ohm)
Max.
deviation Temp °C Resistance (Ohm) Max.
deviation Temp °C Resistance (Ohm) Max.
deviation Temp °C Resistance (Ohm) Max.
deviation
-40 262960 35403 -5 38279 2756 30 8178 296 65 2304 171
-39 247217 32777 -4 36455 2568 31 7866 294 66 2229 168
-38 232539 30358 -3 34731 2393 32 7568 292 67 2158 165
-37 218845 28130 -2 33100 2230 33 7283 290 68 2089 161
-36 206064 26075 -1 31557 2078 34 7011 287 69 2022 158
-35 194110 24178 030029 1932 35 6734 284 70 1960 155
-34 182852 22416 128627 1799 36 6484 281 71 1898 152
-33 172332 20791 227299 1675 37 6244 278 72 1839 149
-32 162498 19290 326042 1560 38 6015 275 73 1782 146
-31 153299 17905 424852 1452 39 5796 271 74 1727 143
-30 144790 16636 523773 1355 40 5575 267 75 1673 140
-29 136664 15444 622708 1261 41 5373 264 76 1622 138
-28 129054 14343 721698 1174 42 5180 260 77 1573 135
-27 121925 13325 820739 1093 43 4995 257 78 1526 132
-26 115243 12383 919829 1017 44 4817 253 79 1480 130
-25 109030 11516 10 18959 946 45 4636 248 80 1432 127
-24 103115 10705 11 18128 879 46 4473 245 81 1390 124
-23 97565 9953 12 17338 817 47 4316 241 82 1349 122
-22 92354 9257 13 16588 759 48 4166 237 83 1310 119
-21 87460 8612 14 15876 705 49 4021 233 84 1272 117
-20 82923 8020 15 15207 654 50 3874 229 85 1235 115
-19 78581 7463 16 14569 607 51 3737 225 86 1199 112
-18 74497 6947 17 13962 563 52 3606 221 87 1163 110
-17 70655 6468 18 13384 522 53 3481 217 88 1130 108
-16 67039 6023 19 12834 484 54 3360 213 89 1097 106
-15 63591 5606 20 12280 447 55 3237 208 90 1067 104
-14 60381 5222 21 11777 413 56 3126 204 91 1038 102
-13 57356 4865 22 11297 382 57 3019 200 92 1009 100
-12 54503 4533 23 10840 353 58 2917 197 93 982 98
-11 51813 4225 24 10404 325 59 2819 193 94 955 96
-10 49204 3932 25 10000 300 60 2720 189 95 927 94
-9 46767 3662 26 9600 300 61 2629 185 96 901 92
-8 44467 3411 27 9218 300 62 2542 182 97 877 90
-7 42296 3177 28 8853 299 63 2458 178 98 853 89
-6 40247 2960 29 8506 297 64 2378 175 99 830 87
Temperature look-up table
SUGGESTED FREQUENCY OUTPUT CIRCUITS
Note: R22=499k /
R4=49.9k / R1=1 k /
RV1=50 k potentiometer /
C1=10nF / C2=2.2nF / C3=100nF
Typical response look-up table (Humidity output)
RH (%) 0 5 10 15 20 25 30 35 40 45 50
Fout (Hz) 7155 7080 7010 6945 6880 6820 6760 6705 6650
RH (%) 55 60 65 70 75 80 85 90 95 100
Fout (Hz) 6600 6550 6500 6450 6400 6355 6305 6260 6210
TECHNICAL DATA
HUMIREL HPC055 Rev0 June 2004 HTS2030SMD
4
QUALIFICATION PROCESS
HTS2030SMD sensors have been qualified through a complete qualification process taking in account
many of the requirements of the JEDEC standard including:
Solder heat and solderability including
lead free process.
Pb free wave soldering and reflo w
soldering process(260°C) + DI water
clean at 45°C
Mechanical shock JESD-22- B104-A
Vibration - Variable frequency(20 to
2000Hz) JESD-22-B103-A
Marking permanency
ESD - Electrostatic Discharge –Air Gun
+-15kV(IEC 1000)
Salt Atmosphere JESD22-A107-A
Temperature Cycling - 40°C / +125°C
High Temperature / Humidity Operating
Life - 93%RH / 60°C for 1000 hours
Low Humidity storage life - RH <
10%/23°C - 1000 hours
Resistance to immersion in water at
ambient temperature and 80°C
High temperature storage 140°C for 168
hours.
Resistance to many chemicals lin ked to
home appliances/automotiv e o r
consumer applications.
ENVIRONMENTAL AND RECYCLING
HTS2030SMD sensors a re lead free compon en t s and are compatible with Pb Free soldering
processes.HTS2030SMD sensors are free from Cr (6+), Cd and Hg.
SOLDERING INSTRUCTIONS
See Application Note. To get it, please contact: application@humirel.com
PACKAGE OUTLINE HTS2030SMD GULL WING (JLEAD option also available)
Dimensions in millimeters
FOOTPRINT
ORDERING INFORMATION of HTS2030SMD:
HPP804B130: TUBE M.P.Q. OF 78 PIECES.
HPP804B131: TAPE AND REEL M.P.Q. OF 1500 PIECES.
TEMPERATURE AND RELATIVE HUMIDITY SENSORS.
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsability is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent
rights to the manufacturer. Humirel reserves the right to make changes without further notice to any product herein. Humirel makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Humirel
assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. « Typical » parameters can and do vary in different applications.
All operating parameters, including « Typical » must be validated for each customer applications by customer’s technical experts. Humirel does not convey any license under its patent rights nor the rights of others. Humirel products are not designed,
intended, or authorized for use as components in systems intended for surgical implant into the body, or other application intended to support or sustain life, or for any application in which the failure of the Humirel product could create a situation where
personal injury or death may occur. Should buyer purchase or use Humirel products for any such unintended or unauthorized application, Buyer shall indemnify and hold Humirel and its officers, employees, subsidaries, affiliates and distributors
harmless against all claims, costs, damages and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of presonal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Humirel
was negligent regarding the design or manufacture of the part.Humirel is a registred trade mark of Humirel.