XPC/XPCL Series and
XPXL Series
Compensated/Calibrated and
Uncompensated/Uncalibrated
Board Mount Pressure Sensors
DESCRIPTION
The XPC/XPCL Series and XPXL Series sensors integrate
silicon micromachined sensing technology, temperature
compensation, and calibration in a complete family of low-cost
packages. This series offers a cost-effective solution for design
requirements.
These piezoresistive pressure sensors use micromachined
silicon chips mounted on ceramic and protected with a plastic
cap. Several tube arrangements with nylon housings are
available for various pressure applications.
On devices of 5 psi and above, the top side of the chip is
protected against humidity by a Silgel® coating.
Although the sensors are designed for use with noncorrosive,
nonionic pressure media, they accommodate many gases that
are used in medical applications.
FEATURES
Low cost, small size
Temperature compensated
Zero and span calibrated
Millivolt output
Differential, gage and absolute pressure
Constant voltage excitation
High impedance - low current
POTENTIAL APPLICATIONS
Medical applications
Applications requiring small size
Applications requiring vacuum and positive pressure
reference or both
XPC/XPCL Series and XPXL Series
2 www.honeywell.com/sensing
Table 1. Electrical Specifications
Characteristic
XPC/XPCL at 12 Vdc, 25 °C [77 °F]
XPXL at 5 Vdc, 25 °C [77 °F]
Min.
Typ.
Max.
Min.
Typ.
Max.
Excitation voltage
3.0
12.0
16.0
3.0
5.0
12.0
Null
-1.0
0
1.0
-50
0
50
Offset temperature shift1
0 C to 25 C [32 F to 77 F]
25 C to 70 C [77 F to 158 F]
±1.0
±0.5
Full scale temperature shift1
0 C to 25 C [32 F to 158 F]
25 C to 70 C [77 F to 158 F]
±2
-1800
PPM/ C
Linearity, hysteresis error2
0.25
1.0
0.25
1.0
Input resistance
5.0
3.0
Output resistance
3.0
3.0
Operating temperature
-25 [-13]
85 [185]
-25 [-13]
85 [185]
Storage temperature
-40 [-40]
125 [257]
-40 [-40]
125 [257]
Common mode pressure
50
50
Notes:
1. Shift is relative to 25 °C [77 °F].
2. Measured at 1/2 full scale rated pressure using BFSL.
Table 2. Absolute Output
FS Pressure
XPC at 12 Vdc, 25 °C [77 °F]
Output Full Scale Span (mV)
Overpressure
(psi)
Min.
Max.
Max.
Max.
5 psi
57
60
63
15
15 psi
85
90
95
45
30 psi
85
90
95
90
60 psi
85
90
95
180
100 psi
95
100
105
250
Table 3. Gage/Differential1 Output
FS Pressure
XPC/XPCL at 12 Vdc, 25 °C [77 °F]
Output Full Scale Span (mV)
XPXL at 5 Vdc, 25 °C [77 °F]
Output Full Scale Span (mV)
Overpressure
(psi)
Min.
Typ.
Max.
Min.
Typ.
Max.
Max.
4 inH2O
23
25
27
50
68
86
3
10 inH2O
19
20
21
45
78.5
112
3
1 psi
17
18
19
40
75
110
3
5 psi
57
60
63
112
168.5
225
15
15 psi
85
90
95
168
253
338
45
30 psi
85
90
95
168
253
338
90
60 psi
85
90
95
189
263.5
338
180
100 psi
95
100
105
210
295
380
250
150 psi
85
90
95
187
262.5
338
250
Note:
1. Differential common mode pressure should not exceed 50 psi.
Figure 1. Mounting Dimensions (For reference only: mm (in).)
D/A Housing
(Differential/Absolute)
GFS/AFS Housing
(Gage/Absolute Offset Axial)
GBFS Housing
(Gage Backside Offset Axial)
Compensated/Calibrated and Uncompensated/
Uncalibrated Board Mount Pressure Sensors
Honeywell Sensing and Control 3
Figure 1. Mounting Dimensions (continued)
GF/AF Housing
(Gage/Absolute Axial)
DF Housing
(Differential Axial)
GBF Housing
(Gage Backside Axial)
GT/AT Housing
(Gage/Absolute Radial)
GBT Housing
(Gage Backside Radial)
DT Housing
(Differential Radial)
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com/sensing
008046-6-EN IL50 GLO Printed in USA
July 2011
© 2011 Honeywell International Inc. All rights reserved.
Figure 2. Equivalent Circuit
Pinout
1. -V Excitation
2. + Output Signal
3. +V Excitation
4. - Output Signal
Media compatibility: Clean, dry gases only.
P1 Port: Media must be compatible with epoxy-based adhesive and silicon gel.
P2 Port: Media must be compatible with nylon housing, epoxy-based adhesive and
silicon.
Order Guide1
XPCL 04 G B F C
Series
XPC - compensated and calibrated (psi)
XPCL - compensated and calibrated (inH20)
XPXL - uncompensated and uncalibrated (inH20)
Pressure Range
04 inH20, 10 inH20
01, 05, 15, 30, 60, 100, 150 psi
Pressure Reference
G - Gage
D - Differential
A - Absolute > 5 psi Port Operation2
B - Backside
Accuracy Grade
(XPC, XPCL only)
C - Commercial
H - High Accuracy
Port Option
F - Axial
T - Radial
FS - Offset Axial2
Notes:
1. Not all combinations may be available. Contact Honeywell representative for details.
2. Option available in ported gage version only.
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific +65 6355-2828
+65 6445-3033 Fax
Europe +44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Honeywell:
XPC150GTC XPC01GTH