Product data sheet
Miniature connectors
Product description Snap-In IP67 cable connector, Contacts: 5, 2.5 - 4.0 mm, Shielding is not possible, solder, IP67, VDE
Area Snap-In IP67 series 720
Order number 99 9113 03 05
Illustration Scale drawing Contact arrangement
You can find the component part drawing and assembly instructions on the next page.
Technical data
General values
Connector design cable connector
Connector locking system snap
Termination solder
Wire gauge (mm) 0.75 mm²
Wire gauge (AWG) 18
Cable outlet 2.5 - 4.0 mm
Upper limit temperature 85 °C
Lower limit temperature – 25 °C
Customs tariff number 85369010
Cable data
Approval 1 VDE
Electrical values
Rated current (40 °C) 5 A
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 2
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Insulation resistance ≥ 10¹⁰ Ω
EMC compliance Shielding is not possible
Degree of protection IP67
Mechanical operation > 500 Mating cycles
Material
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PA (UL 94 V-0)
Housing material PA
Date: 2019-06-09 - Page 1 of 3
Product data sheet
Miniature connectors
Product description Snap-In IP67 cable connector, Contacts: 5, 2.5 - 4.0 mm, Shielding is not possible, solder, IP67, VDE
Area Snap-In IP67 series 720
Order number 99 9113 03 05
Component part drawing
Assembly instructions / Panel cut-out
Date: 2019-06-09 - Page 2 of 3
Product data sheet
Miniature connectors
Product description Snap-In IP67 cable connector, Contacts: 5, 2.5 - 4.0 mm, Shielding is not possible, solder, IP67, VDE
Area Snap-In IP67 series 720
Order number 99 9113 03 05
Security notices
The connector must not be connected or separated under load. Non-observance and incorrect use can result in
personal injury.
The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible
for checking whether the connectors are suitable for use in other applications.
To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life
parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate
adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE
0140-1).
Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under
the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and
standards into account.
Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the
connectors must be separately protected against corrosion. For further information about IP degrees of protection
refer to ‘Technical support’ in the Download Centre.
Powered by TCPDF (www.tcpdf.org)