9261 Owensmouth Ave.
Chatsworth, Ca 91311
Phone: (818) 701-4933
Fax: (818) 701-4939
MP3505
THRU
MP3510
35 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
MP-50
Features
Mounting Hole For #8 Screw
Plastic Case With Metal Bottom
Any Mounting Position
Surge Rating Of 400 Amps
DIMENSIONS
INCHES MM
DIM MIN MAX MIN MAX NOTE
A--- 1.140 --- 29.00
B--- .452 --- 11.50
C.425 .480 10.80 12.20
D.693 .732 17.54 18.6
E.637 .677 16.20 17.20
G.188 --- 4.77 ---
H.633 .673 16.10 17.10
J.543 .582 13.80 14.80
Maximum Ratings
Operating Temperature: -55°C to +175°C
Storage Temperature: -55 °C to +175°C
Microsemi
Catalog
Number
Device
Marking Maximum
Reccurrent
Peak Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
MP3505 MP3505 50V 35V 50V
MP351 MP351 100V 70V 100V
MP352 MP352 200V 140V 200V
MP354 MP354 400V 280V 400V
MP356 MP356 600V 420V 600V
MP358 MP358 800V 560V 800V
MP3510 MP3510 1000v 700V 1000v
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current IF(AV) 35.0A TJ = 55°C
Peak Forward Surge
Current IFSM 300A 8.3ms, half sine
Maximum Forward
Voltage Drop Per
Element VF1.1V IFM = 17.5A per
element;
TJ = 25°C*
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR10µA
1.0mA TJ = 25°C
TJ = 100°C
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
Santa Ana: (714) 979-8220 Scottsdale: (602) 941-6300 Colorado: (303) 469-2161 Watertown: (617) 926-0404 Chatsworth: (818) 701-4933
Sertech Labs: (617) 924-9280 Ireland: (353) 65-40044 Bombay: (91) 22-832-002 Hong Kong: (852) 2692-1202
B
C
E
AC
+
-
A
AC
G
H
A
D
J
MP3505 thru MP3510
Santa Ana: (714) 979-8220 Scottsdale: (602) 941-6300 Colorado: (303) 469-2161 Watertown: (617) 926-0404 Chatsworth: (818) 701-4933
Sertech Labs: (617) 924-9280 Ireland: (353) 65-40044 Bombay: (91) 22-832-002 Hong Kong: (852) 2692-1202
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
Figure 3
Forward Derating Curve
25 50 100 150 175
0
0
10
20
30
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°C
75
40
50
60
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
Volts
4
6
20
10
Amps
.2 1.2
.4 .6 .8 1.0
.01
.02
.04
.06
.1
.2
.4
.6
1
225°C
40
60
100
Figure 2
Typical Reverse Characteristics
Volts
.4
.6
2
1
µ
Amps
20 120
40 60 80 100
.001
.002
.00
4
.006
.01
.02
.04
.06
.1
.2
4
6
10
140
TJ=25°C
1 100
4
0
100
200
300
8
Figure 4
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10 20 60 80
40
00
400
500
600