Amphenol 482GB Series Circular Environmental Connector Description The 482 Series are EMI filter connectors which are designed to meet the mechanical and environmental requirements of MIL-C-26482. The connectors will accept filter, power or grounding contacts or EMI seal plugs or any combination thereof. Connectors are available with front release rear removable crimp type contacts or fixed contacts with solder bucket or pin tail termination. Mating Connector Information 482 Series connectors mate with connectors conforming to MIL-C-26482, MIL-C-83723, BS9522 N0001 - AMPHENOL's 162 Series, BS9522 F0017 - AMPHENOL's 62 Series, AMPHENOL's 602GB Series. Amphenol TESTED TO BS9522 F0027 Contents Page Introduction .................................................................................................................... 2 Design Features ............................................................................................................. 2 Insert Arrangements ........................................................................................................ 2-3 Keyway Orientations ....................................................................................................... 3 Shell Styles and Dimensions ............................................................................................ 4-7 Contacts ...................................................................................................................... 8 Typical Insertion Loss ..................................................................................................... 8 Contact Specifications .................................................................................................... 9-10 Ordering Information ...................................................................................................... 11 Tools .......................................................................................................................... 12 Contact Insertion / Removal Operations .............................................................................13-14 1 Introduction AMPHENOL's Filter connectors are a system of reliability engineered receptacles, plugs, contacts and accessories, designed to provide a wide range of performance and servicing features not previously available with ordinary EMI filtering connectors. These connectors are rugged enough to operate reliably under high physical stress, and in the demanding environmental conditions required of power connections. The patented stress isolated EMI filter is composed of a ceramic element attached to a sturdy contact in a way that dampens all connector stresses and virtually eliminates the chance of ceramic fracture due to vibration, thermal and physical shock. Once inserted in the connector, the filter contact is engaged by a Microstrip grounding plate designed to achieve maximum insertion loss and to inhibit resonances due to series inductance. FILTER HERE NOT HERE The use of filter connectors has the following advantages: * * * * * Space saving Weight saving Reduction in solder connections Eliminates requirement for RFI screened box Provides low impedance ground plane for filter network Design Features Note: Newly improved design meets mated and unmated water pressure-sealing requirements of MIL-C-5015 1. 2. 3. Self-Sealing two riser front insert * (Silicone Rubber) Diaphragm rim seal * (Silicone Rubber) Moulded one-piece contact retention system. (High temp Thermoplastic) 4. Stress isolated, filter contacts 5. Microstrip EMI grounding plate - plated Copper Alloy 6. High temperature contact heat dissipater plate 7. Visual servicing condition indicator 8. Safety grip locking ring 9. Vibration proof detent spring 10. Self-sealing three riser grommet (Silicone Rubber) Insert Arrangements Normal position with pin contacts Alternative position of insert with socket contacts. (O ANTI-clockwise). Each diagram shows mating face of insert Alternative position of insert with pin contacts (O clockwise) 2 Insert Arrangements contd Alternate Insert Positions SHELL SIZE 8 3 CONTACTS SIZE 20 SHELL SIZE 14 19 CONTACTS SIZE 20 SHELL SIZE 10 6 CONTACTS SIZE 20 Insert Arrangement 8-33 10-6 12-10 14-19 16-26 18-32 20-41 22-55 24-61 SHELL SIZE 12 10 CONTACTS SIZE 20 a Degrees Normal 0 0 0 0 0 0 0 0 0 W 90 90 60 30 60 85 45 30 90 X 155 165 138 126 142 180 Y 270 315 275 222 225 226 270 Z 295 338 265 314 324 SHELL SIZE 16 26 CONTACTS SIZE 20 SHELL SIZE 24 61 CONTACTS SIZE 20 SHELL SIZE 22 55 CONTACTS SIZE 20 SHELL SIZE 20 41 CONTACTS SIZE 20 SHELL SIZE 18 32 CONTACTS SIZE 20 Keyway Orientations Datum Datum is always taken from major key or keyway. In receptacles the major keyway always remains fixed in relation to the mounting flange. For the B, C, E and F orientations, the three bayonet locations and associated minor keyways are rotated complete, in accordance with the table below. 3 Pins spaced 120o apart N.B. The accompanying diagram shows a receptacle shell, with keyways. Corresponding key orientations for a mating plug shell are therefore always clockwise. Shell Size 8 10 12 14 16 18 20 22 24 Shell Size 8 10 12 14 16 18 20 22 24 3 N 105 105 105 105 105 105 105 105 105 VALUES FOR a (degrees) B C E F 118 82 85 125 115 85 89 121 115 85 91 119 75 120 93 117 75 120 95 115 75 120 95 115 75 120 97 113 75 120 97 113 75 120 N 50 50 50 50 50 50 50 50 50 N 35 35 35 35 35 35 35 35 35 VALUES FOR f (degrees) B C E 30 50 50 30 50 50 30 50 50 30 50 50 30 50 50 30 50 50 30 50 50 30 50 50 30 VALUES FOR O (degrees) B C E 30 35 35 30 35 35 30 35 35 30 35 35 30 35 35 30 35 35 30 35 35 30 35 35 30 F 45 45 45 35 35 35 35 35 35 N 60 60 60 60 60 60 60 60 60 F 50 50 50 30 50 50 50 50 50 N 75 75 75 75 75 75 75 75 75 VALUES FOR (degrees) B C E 100 75 75 100 75 75 100 75 75 100 75 75 100 75 75 100 75 75 100 75 75 100 75 75 100 VALUES FOR ? (degrees) B C E 73 40 80 70 44 76 70 46 74 30 48 72 30 50 70 30 50 70 30 52 68 30 52 68 30 F 75 75 75 75 75 75 75 75 75 F 47 50 50 75 75 75 75 75 75 Dimensions and Shell Sizes Square Flange Mounting Receptacle (with fixed contacts) 482GB-12AXX-\XXXX(XXX) Shell Size 4 HOLES OH A MAX B MAX C MAX D MAX 1.412 35.86 1.266 32.16 .652 16.56 .086 2.18 .777 19.73 .777 19.73 .810 20.57 0.98 2.49 C MAX D MAX 1.505 1.331 .710 38.23 33.81 18.03 .105 2.67 1.567 39.80 .153 3.89 8 E SQ. 10 12 14 F CRS 16 18 A B 20 22 24 OG C E SQ MAX .822 20.88 .952 24.18 1.042 24.46 1.142 29.00 1.232 31.29 1.322 33.58 1.452 36.88 1.572 39.93 1.702 43.32 F MAX .594 15.08 .719 18.26 .812 20.62 .906 23.01 .969 24.61 1.062 26.97 1.156 29.36 1.250 31.75 1.375 34.92 GO MAX .473 12.06 .590 14.99 .750 19.05 .875 22.22 1.000 25.40 1.125 28.57 1.250 31.75 1.375 34.92 1.500 38.10 HO J MAX MAX E SQ MAX .750 19.05 .875 22.22 1.062 26.97 1.187 30.15 1.312 33.32 1.437 36.50 1.562 39.67 1.687 42.85 1.812 46.02 F MAX 1.069 27.15 1.194 30.34 1.382 35.10 1.507 38.28 1.632 41.45 1.757 44.63 1.945 49.40 2.078 52.78 2.194 55.73 GO MAX .473 12.06 .590 14.99 .750 19.05 .875 22.22 1.000 25.40 1.125 28.57 1.250 31.75 1.375 34.92 1.500 38.10 H MAX .954 24.23 1.077 24.23 1.265 32.13 1.388 35.25 1.515 38.48 1.640 41.66 1.825 46.36 1.953 49.61 2.075 52.70 .117 2.97 0.82 2.08 .207 5.25 .145 3.68 D J PANEL THICKNESS Single Hole Mounting Receptacle (with fixed contacts) 482GB-13AXX-XXXX(XXX) Shell Size H SQ. F A MAX B MAX 08 10 12 14 16 E 18 20 A B 22 24 1.393 35.38 .899 22.83 .932 23.67 J MAX .125 3.17 .250 6.35 OG C D J PANEL THICKNESS Dimensions Inches Millimetres 4 Dimensions and Shell Sizes Square Flange Mounting Receptacle (Back Mounting Only) Shell A Size MAX 482GB-12EXX-XXXX(104) E SQ. B MAX C MAX D MAX .750 19.05 .875 22.22 1.000 25.40 1.125 28.57 1.250 31.75 1.375 34.92 1.531 38.88 1.656 42.06 1.781 45.24 E MAX .828 21.03 .954 24.23 1.047 26.59 1.141 28.98 1.234 31.34 1.328 33.73 1.453 36.90 1.578 40.08 1.703 43.26 F MAX .594 15.09 .719 18.26 .812 20.62 .906 23.01 .969 24.61 1.062 26.97 1.156 29.36 1.250 31.75 1.375 34.92 GO MAX .473 12.01 .590 14.99 .750 19.05 .875 22.22 1.000 25.40 1.125 28.57 1.250 31.75 1.375 34.92 1.500 38.10 HO MAX J MAX 1.765 44.83 .078 1.98 .441 11.20 .120 3.05 .082 2.08 1.821 16.31 .110 2.80 .566 14.38 .599 15.22 .147 3.73 .207 5.25 D MAX .750 19.05 .875 22.22 1.000 25.40 .722 1.125 18.34 28.57 1.250 31.75 1.375 34.92 1.531 38.88 .910 1.656 23.11 42.06 .943 1.781 23.95 45.24 E MAX .954 24.23 1.078 27.38 1.266 32.15 1.391 35.33 1.516 38.50 1.641 41.68 1.828 46.43 1.954 49.63 2.078 52.78 F MAX 1.078 27.38 1.203 30.55 1.391 35.33 1.516 38.51 1.641 41.68 1.766 44.85 1.954 49.63 2.078 52.78 2.203 55.95 GO MAX .430 10.92 .558 14.17 .711 18.06 .831 21.10 .956 24.28 1.056 26.82 1.181 30.00 1.306 33.17 1.431 36.35 HO MAX .750 19.05 .875 22.22 1.062 26.97 1.187 30.15 1.312 33.32 1.437 36.50 1.562 39.67 1.687 42.85 1.812 46.02 J MAX 8 10 12 F CRS 14 16 4 HOLES O H 18 A UNLOCKED 0.85 MAX 20 22 D G C 24 B MAX J PANEL THICKNESS Single Hole Mounting Receptacle Shell Size 482GB-13EXX-XXXX(104) A MAX B MAX 1.785 44.83 .138 3.51 1.826 46.38 .168 4.27 8 E SQ. 10 F 12 14 H 16 18 20 A UNLOCKED C B 0.85 MAX 22 24 D G J PANEL THICKNESS Dimensions Inches Millimetres 5 C MAX .125 3.17 .250 6.35 Square Flange Mounting Receptacle with Cinch Nuts 482GB-15EXX-XXXX(104) Shell Size E SQ A MAX B MAX 8 10 12 F CRS 14 .078 1.98 1.826 46.83 .110 2.79 A MAX B C .016 MAX 0.41 18 20 22 A UNLOCKED 24 0.85 MAX D MAX .750 19.05 .875 22.22 1.000 25.40 .441 1.125 11.20 28.57 1.250 31.75 1.375 34.92 1.531 38.88 .566 1.656 14.38 42.06 .599 1.781 15.21 45.24 1.765 44.83 16 4 HOLES 4-40 UNC-2B C MAX E MAX F MAX GO MAX .828 21.03 .954 24.23 1.047 26.59 1.141 28.98 1.234 31.34 1.328 33.73 1.453 36.90 1.578 40.08 1.703 43.25 .594 15.09 .719 18.26 .812 20.62 .906 23.01 .969 24.61 1.062 26.97 1.156 29.36 1.250 31.75 1.375 34.92 .473 12.01 .590 14.99 .750 19.05 .875 22.22 1.000 25.40 1.125 28.57 1.250 31.75 1.375 34.92 1.500 38.10 E MAX J MAX J MAX .082 2.08 .207 5.25 OD OG C B J PANEL THICKNESS Square Flange Receptacle (with Strain Relief Clamp) (Back Mounting only) 482GB-12FXX-XXXX(904) Shell Size J (typ) 8 10 12 K (typ) 14 16 4 HOLES OL 18 20 A UNLOCKED 22 24 DO MAX 2.750 .473 69.85 12.01 2.750 .590 69.85 14.99 2.750 .750 69.85 19.05 2.750 0.078 .441 .875 69.85 1.98 11.20 22.22 2.900 1.000 73.66 25.40 2.900 1.125 73.66 28.57 3.500 1.250 88.90 31.75 3.600 .110 .566 1.375 91.44 2.80 14.38 34.92 3.800 .599 1.500 96.52 15.21 38.10 .082 2.08 2.07 5.25 0.820 20.82 .950 24.13 1.040 26.42 1.140 28.96 1.230 31.24 1.320 33.53 1.450 36.83 1.570 39.88 1.700 43.18 K .005 0.13 0.594 15.09 0.719 18.26 0.812 20.62 0.906 23.01 0.969 24.61 1.062 26.97 1.156 29.36 1.250 31.75 1.375 34.92 LO .120 3.05 .147 3.78 OD C B E PANEL THICKNESS Dimensions Inches Millimetres 6 Single Hole Mounting Receptacle (with Strain Relief Clamp) 482GB-13FXX-XXXX(904) Shell Size 8 E SQUARE 10 F 12 G 14 16 18 20 A UNLOCKED 22 24 A MAX 2.75 69.85 2.75 69.85 2.75 69.85 2.750 69.85 2.900 73.66 2.900 73.66 3.200 81.28 3.600 91.44 3.800 96.52 B C .138 3.51 .722 18.34 .168 4.27 .910 23.11 .943 23.95 E MAX F MAX 0.954 24.23 1.078 27.38 1.266 32.16 1.391 35.33 1.516 38.51 1.641 41.68 1.828 46.43 1.954 49.63 2.078 52.78 1.078 27.38 1.203 30.56 1.391 35.33 1.516 38.51 1.641 41.68 1.766 44.86 1.954 49.63 2.078 52.78 2.203 55.96 G .015 0.38 0.750 19.05 .875 22.22 1.062 27.05 1.187 30.15 1.312 33.32 1.437 36.50 1.562 39.67 1.687 42.85 1.812 46.02 HO MAX .473 12.01 .590 14.99 .750 19.05 .875 22.22 1.000 25.40 1.125 28.57 1.250 31.75 1.375 34.92 1.500 38.10 J .125 3.17 .250 6.35 H C Note: Amphenol have the ability to respond to special requirements which can be dealt with directly with the factory B J PANEL THICKNESS Panel Cutouts (for all types of 482GB connectors) M Shell Size L 8 10 12 Single Hole Mounting Panel Cutout 14 16 K (typ) M 18 20 22 Square Flange Panel Cutout Maximum panel thickness is .125" for shell sizes 8 through 18, and .250" for shell sizes 20, 22 and 24. Max Dimensions Inches Millimetres 7 24 K .005 .013 0.594 15.09 0.719 18.26 0.812 20.62 0.906 23.01 0.969 24.61 1.062 26.97 1.156 29.36 1.250 31.75 1.375 34.92 L M +.010 -.005 +0.25 -0.13 0.540 13.72 0.665 16.89 0.828 21.03 0.952 24.18 1.076 27.33 1.201 30.51 1.326 33.68 1.451 36.86 1.576 40.03 +.010 -.005 +0.25 -0.13 0.572 14.53 0.697 17.70 0.885 22.48 1.010 25.65 1.135 28.83 1.260 32.00 1.385 35.18 1.510 38.35 1.635 41.53 482 Series Contacts Contact Circuit Types Best Filtering Application P1 FERRITE LRC FERRITE CLR FERRITE Unknown or medium source and load impedance Low source and high load impedance (EMI Direction High source and low load impedance ( EMI Direction) High source and low load impedance (EMI Direction Low source and high load impedance ( C ) ) EMI Direction) High source and high load impedance High source or load impedance >100O Low source or load impedance <10O Typical Insertion Loss Tests performed in strict accordance with MIL-STD-220 (No-Load) on Contacts in a 482 Series Connector mated with a Standard Non-Filter Connector. CAUTION - Comparison with other filter connector manufacturers data may be misleading unless the following factors are taken into account: Is official (unmodified) MIL-STD-220 test method utilised as basis for performance depicted? - modification will result in an apparent (fictitious) higher response! (2) Is performance shown for filter contacts installed in connectors? - if performance is based on discrete (single) contacts tested to MIL-STD-220, higher levels of I.L. will be indicated due to the grounding limitations inherent in any connector design. INSERTION LOSS (dB) (1) 80 60 40 20 0 0.001 0.01 0.1 1 10 100 1000 FREQUENCY (MHz) 8 Contact Specifications FILTER CONTACT TYPE Pin Contact Part Number Socket Colour Code FR = FRONT BACK = BK 482-192 482-22 482-102 482-142 482-192S 482-22S 482-102S 482-142S FR BK FR BK FR BK FR BK Grn Grn Red Red Blu Blu Yel Yel Circuit Type Pi Pass Band dc to 3dB cut-off frequency Fco = Capacitance (picofarads) @ 25oC - minimum @ 1KHz (-0) (+100%) Working Voltage Sea Level @ 85oC (50mA max. charging current) @ 125oC Dielectric Withstanding Voltage (dc) (50mA max. charging current) 2.5MHz 400KHz 250KHz 450 2500 15,000 20,000 100 50 dc 200 ac (rms) 125 200 60 30 dc 200 150 100 50 ac (rms) 125 60 30 600 300 150 100 - @ 25oC Corona Withstanding Voltage (ac-rms) -minimum Insulation Resistance (gigaohms) -minimum 15MHz @ 25oC - 300 10 5 10 Current Rating (amperes) -maximum ** dc and low frequencies 5 Filter rf Current (amperes) - minimum ** at any frequency Operating Temperature Range ** 0.25 (oC) -55 to +150 Insertion Loss (decibels )@ 25oC - minimum per MIL-STD-220 (No Load) at 0.1MHz - - - - (Performance in Mated Connectors) 1MHz - - 5 9 For Typical IL Curve 10MHz - 8 28 31 See Page 8 (Results will vary with temperature 100MHz 24 56 65 60 source and load impedance) 1000MHz 55 62 55 55 Crosstalk Attenuation (decibels) (coupling between contacts) - minimum at 100MHz Power to Filter 25 Filter to Filter 60 * Consult AMPHENOL FACTORY if your filter needs are not reflected in this catalogue. ** Upper limit is the maximum allowable internal hot spot temperature resulting from any combination of electrical load and ambient. 9 Contact Specifications Contd FILTER 482-92 482-92A 482-92B 482-92S 482-92AS 482-92BS FR BK FR BK FR BK Yel Blu - Blu Blu - C LRC 482-122 482-122B 482-82 482-82A 482-82B 482-162 482-51 482-122S 482-122AS 482-122BS 482-82S 482-82AS 482-82BS 482-162S 482-51S FR FR BK FR BK FR BK FR BK FR BK - Yel Blk - Blk Blk - Yel Brn BK Yel Wht CLR C 482-122A POWER FR - BK Wht Wht LRC CLR C LRC CLR N/A C N/A 150KHZ 100KHz 70KHz 10KHz N/A 40,000 50,000 90,000 500,000 N/A 100 30 700 60 - 500 100 30 700 60 - 500 300 90 2,000 200 120 80 200 120 80 600 200 - 100 - 1000 10 10 5.5 0.9 50 5 7.5 0.25 N/A -55 to +150 14 32 42 45 Same performance as for 'C' version under MIL-STD-220 but improved filtering offered for other Zs and Zl values 3.5 16 33 45 Same performance as for 'C' version under MIL-STD-220 but improved filtering offered for other Zs and Zl values 50 4 21 35 47 55 Same performance as for 'C' version under MIL-STD-220 but improved filtering offered for other Zs and Zl values 17 37 49 N/A 49 55 25 60 N/A * Consult AMPHENOL FACTORY if your filter needs are not reflected in this catalogue. ** Upper limit is the maximum allowable internal hot spot temperature resulting from any combination of electrical load and ambient. 10 Ordering Information Ordering by Amphenol Part Number 482GB - 1 3 E 22 - 55 P N - 104 Series: 482GB Contact Combination: (104) - Less Contacts with tin plating (662) - Less Contacts with olive drab plating (904) - Less Contacts but incl. Cable Clamp (XXX) - with fixed contacts, deviation signifies type of contacts and positions Coupling Style: 1 - Bayonet Shell Styles: 2 - Square Flange Receptacle 3 - Single Hole Mounting Receptacle Insert Position N W X Y Z Environmental Class: A - Plain shell, fixed contacts E - Grommet Seal, Gang contact insertion/removal F - Grommet Seal with strain Relief clamp, Gang contact insertion/removal Or Contact Style: P - Pin S - Socket Insert Arrangements Shell Size No. of Contacts 8 3 (33) 10 6 10 12 14 19 16 26 18 32 20 41 22 55 24 61 Ordering Contacts Only 482 Series: 482 Contact Type 82 Filter Contact - Refer to Pages 9 and 10 Power Contact - 482-51 Ground Contact - 482-49 EMI Sealing Plug - 482-50 11 - 82 S Contact Style: S - Socket Omit for Pin Style Keyway Position N B C E F Tools M22520/2-01 Crimp Tool 494GB-0001 Locator Insertion Tool Pin Contact Tool - 494GB-0002 Socket Contact Tool - 494GB-0003 (494GB-0002 shown) Removal Tool Pin Contact Tool - 494GB-0002 Socket Contact Tool - 494GB-0003 (494GB-0002 shown) Recommended Crimp Tool Setting Amphenol Part Number Daniels Description Contact Size Crimp Tool (M22520/2-01) 494GB-0001 Crimp Tool Locator for use with 357-100 Crimp Tool 494GB-0002 Contact Insertion/Removal Tool for Pin Contacts 494GB-0003 Contact Insertion/Removal Tool for Socket Contacts 20 Wire Size Crimp Jaw Setting 24 No. 6 22 No. 7 20 No. 7 Recommended Panel Nut Torque Single Hole Fixing Connectors Shell Size Nm Lbs.f.ins 8 10 12 14 16 18 20 22 24 3.73 4.07 6.78 7.34 8.25 9.26 11.98 13.90 15.03 33 36 60 65 73 82 106 123 133 22 24 Recommended Cable Clamp Torque Shell Styles 12F/13F Shell Size Nm 8 10 12 14 16 18 20 2 2 2 2 2 3 3 Lbs.f.ins 17.7 17.7 17.7 17.7 17.7 26.6 26.6 3 3 26.6 26.6 12 AMPHENOL 482 Series Assembly Instructions Step 1 Strip Wire to dimension shown in Fig. 1. Fig.1 Step 2 To crimp contact, firstly check jaw setting for wire size as indicated in table 1. Insert contact into crimp tool M22520/2-01. Place prepared wire into crimp barrel and close tool handle firmly (Fig. 2). Release tool handle and remove contact, the contact is now ready for use. Correct wire positioning may be checked through the inspection hole in crimp barrel. Fig. 2 Step 3 The connector when removed from packaging will be in the "unlocked" position as indicated by the exposure of the red colour band on the shell. The connector is ready for contact insertion. Note: Inserting or removing contacts from a connector in the "locked" position will damage both contact and connector. If the connector is locked and the red band is not visible, follow "unlocking procedure in Step 7. Step 4 To insert the contact into the connector use 494GB-0002 tool for pin contacts and 494GB-0003 for socket contacts. Snap the contact crimp barrel into the insertion tool, the tool should rest on the bearing shoulder of the contact, dress the wire along the bore of the tool (Fig. 3) Fig. 3 Step 5 Insert the contact into the appropriate grommet location positioning the tool parallel with the axis of the connector and applying a steady force (Fig. 4). The contact is located when a click is heard and a stop is felt simultaneously. Withdraw the tool. Note: The contacts are held sufficiently to permit handling, the connector must be locked for operation. Fig. 4 13 Step 6 To lock the connector, push back and hold the detent spring tab (Fig. 5) and rotate the knurled lock nut clockwise - 2 turns. The tab will drop back into the slot. It should not be possible to rotate the knurled lock nut further than one full tab width past this position. The red indicator band will now be covered by the knurled lock ring. The connector is now ready for operation. Fig. 5 Step 7 To remove the contact, unlock the connector by pushing back and holding the detent spring tab and rotating the knurled lock nut anti-clockwise - 2 turns, the red colour band is now visible. Fig. 6 Step 8 Position the contact removal tool over the contact (Fig. 6). Hold the tool parallel with the axis of the connector and apply a steady force until the contact releases. The contact can now be removed by gently pulling the wire from the rear of the connector (Fig. 7). Fig. 7 14 Notice: Products are sold subject to Amphenol's Conditions of Sale ("the standard conditions"). All specifications and statements contained herein are believed to be correct at the time of printing but no representation or warranty, express or implied, is given as to any specification or statement contained herein. Product specifications including performance characteristics are typical only and subject to deviation. Specifications are also subject to change without notice. Users should not assume that all safety measures are indicated or that other measures may not be required. No representation or warranty, express or implied, is given that any use of products (including any stated or suggested use) does not infringe any patent, registered design or other third party rights and no stated or suggested use of products can be taken to recommend any such infringement. Amphenol Thanet Way, Whitstable, Kent. CT5 3JF Tel: 01227 773200 Fax: 01227 276571