MOS FET Relays G3VM-61BR/ER New Analog-switching MOS FET Relays Featuring a High Capacity of 2.5 A. * Switches minute analog signals. * Low ON-resistance of 0.1 max. * Continuous load current of 2.5 A. * RoHS compliant Application Examples * Measurement devices * Security systems Note: The actual product is marked differently from the image shown here. List of Models Contact form SPST-NO Terminals Load voltage (peak value) PCB terminals 60 VAC Model G3VM-61BR Surface-mounting terminals Number per stick Number per tape 50 --- --- 1,500 G3VM-61ER G3VM-61ER(TR) Dimensions Note: All units are in millimeters unless otherwise indicated. G3VM-61BR G3VM-61ER 7.120.25 6.40.25 7.120.25 6.40.25 7.620.25 7.620.25 0.80.25 3.65+0.15 -0.25 3.65+0.15 -0.25 0.25+0.1 -0.05 Note: The actual product is marked differently from the image shown here. 1.20.15 0.50.1 2.540.25 2.5 min. 7.85 to 8.80 Weight: 0.4 g Note: The actual product is marked differently from the image shown here. 4.0+0.25 -0.2 1.0 min. 1.20.15 1.0 min. 10.0 max. 2.540.25 Weight: 0.4 g Terminal Arrangement/Internal Connections (Top View) G3VM-61BR 6 1 4 2 3 PCB Dimensions (Bottom View) G3VM-61BR 2.54 G3VM-61ER Five, 0.8-dia. holes (0.61) 6 1 4 3 2 Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-61ER 2.54 2.54 2.54 8.3 to 8.8 (1.52) (0.61) (1.52) 1.3 1.5 MOS FET Relays G3VM-61BR/ER 19 Absolute Maximum Ratings (Ta = 25C) Item Input Output Symbol Rating Unit Measurement Conditions LED forward current IF 30 mA Repetitive peak LED forward current IFP 1 A 100 s pulses, 100 pps LED forward current reduction IF/C rate -0.3 mA/C Ta 25C LED reverse voltage VR 5 V Connection temperature Tj 125 C Load voltage (AC peak/DC) VOFF 60 V Continuous load current IO 2,500 mA ON current reduction rate ION/C -22 Connection temperature Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Ta 25C mA/C Tj 125 C Dielectric strength between input and output (See note 1.) VI-O 2,500 Vrms AC for 1 min Operating temperature Ta -20 to +85 C With no icing or condensation Storage temperature Tstg -40 to +125 C With no icing or condensation Soldering temperature (10 s) --- 260 C 10 s Electrical Characteristics (Ta = 25C) Item Input Symbol Minimum Typical Maximum Measurement conditions Unit LED forward voltage VF 1.18 1.33 1.48 V IF = 10 mA Reverse current IR --- --- 10 A VR = 5 V Capacity between terminals CT --- 70 --- pF V = 0, f = 1 MHz Trigger LED forward current IFT --- 1.0 3 mA IO = 1 A RON --- 0.065 0.1 IF = 10 mA, IO = 2 A Current leakage when the relay is open ILEAK --- 1.0 10 nA VOFF = 60 V Capacity between terminals COFF --- 400 600 pF V = 0, f = 1MHz Output Maximum resistance with output ON Capacity between I/O terminals CI-O --- 0.8 --- pF f = 1 MHz, Vs = 0 V Insulation resistance RI-O 1,000 --- --- M VI-O = 500 VDC, RoH 60% Turn-ON time tON --- 1.0 1.5 ms Turn-OFF time tOFF --- 0.2 0.4 ms IF = 10 mA, RL = 200 , VDD = 20 V (See note 2.) Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) VDD --- --- 48 V Operating LED forward current IF 10 --- 20 mA Continuous load current (AC peak/DC) IO --- --- 2,500 mA Operating temperature 25 --- 60 C 20 Ta MOS FET Relays G3VM-61BR/ER Note: 2. Turn-ON and Turn-OFF Times IF 1 6 2 4 RL VDD VOUT IF VOUT 10% t ON 90% t OFF Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature IO - Ta 40 30 20 10 20 40 60 80 100 2 1 0 -20 120 0 Continuous load current vs. On-state voltage 20 40 Ta = 25 C I F = 10 mA 1 0 -1 -2 -50 0 50 100 100 3 1 0.5 0.1 0.6 120 0.8 1 40 60 80 100 IO = 2 A 4 3 2 1 0 -20 0 20 Turn ON, Turn OFF time tON, tOFF (S) Ta = 25 VDD = 20 V, RL = 200 3000 1000 t ON 300 t OFF 100 20 LED forward current IF (mA) 30 80 100 I LEAK - Ta 10000 t ON 1000 t OFF 300 60 Current leakage vs. Ambient temperature VDD = 20 V RL = 200 , I F = 5 mA 3000 40 Ambient temperature Ta () tON, tOFF - Ta 10000 1.8 5 Turn ON, Turn OFF time vs. Ambient temperature 30000 1.6 IFT - Ta 50 20 1.4 Trigger LED forward current vs. Ambient temperature 100 0 1.2 LED forward voltage VF (V) 150 tON, tOFF - IF Turn ON, Turn OFF time tON, tOFF (S) 5 Ambient temperature Ta () 30000 10 80 IO = 2 A I F = 10 mA 0 -20 150 Turn ON, Turn OFF time vs. LED forward current 0 60 200 On-state voltage VON (mV) 30 10 RON - Ta On-state resistance RON (m) Continuous load current IO (A) IO - VON -100 30 On-state resistance vs. Ambient temperature 3 -3 -150 Ta = 25 C 50 Ambient temperature Ta Ambient temperature Ta () 2 100 0.3 Trigger LED forward current I F T (mA) 0 3 Current leakage ILEAK (nA) 0 -20 IF - VF 4 LED forward current I F (mA) 50 Continuous load current I O (A) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 1000 VOFF = 60 V 100 10 100 30 -20 0 20 40 60 80 100 Ambient temperature Ta ( MOS FET Relays 1 -20 0 20 40 60 80 100 Ambient temperature Ta () G3VM-61BR/ER 21 All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC Global - http://www.omron.com USA - http://www.components.omron.com 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. X302-E-1 MOS FET Relays 12/10 Specifications subject to change without notice G3VM-61BR/ER Printed in USA