MOS FET Relays G3VM-61BR/ER 19
MOS FET Relays
G3VM-61BR/ER
New Analog-switching MOS FET Relays Featuring
a High Capacity of 2.5 A.
Switches minute analog signals.
Low ON-resistance of 0.1 Ω max.
Continuous load current of 2.5 A.
RoHS compliant
Application Examples
Measurement devices
Security systems Note: The actual product is marked differently from the image shown
here.
List of Models
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminal Arrangement/Internal Connections (Top View)
PCB Dimensions (Bottom View) Actual Mounting Pad Dimensions
(Recommended Value, Top View)
Contact form Terminals Load voltage (peak value) Model Number per stick Number per tape
SPST-NO PCB terminals 60 VAC G3VM-61BR 50 ---
Surface-mounting
terminals
G3VM-61ER
G3VM-61ER(TR) --- 1,500
7.12±0.25
6.4±0.25
2.54±0.25
1.2±0.15
7.62±0.25
10.0 max.
1.0 min.
1.0
min.
3.65
+0.15
0.25
4.0
+0.25
0.2
7.12±0.25
6.4±0.25
2.54±0.25
1.2±0.15
0.5±0.1
0.8±0.25
7.62±0.25
7.85 to 8.80
3.65
+0.15
0.25
0.25
+0.1
0.05
2.5 min.
G3VM-61BR G3VM-61ER
Note: The actual product
is marked different-
ly from the image
shown here.
Note: The actual product
is marked different-
ly from the image
shown here. Weight: 0.4 g Weight: 0.4 g
64
13
2
G3VM-61BR G3VM-61ER
64
13
2
Five, 0.8-dia. holes
2.54
2.54
(0.61)
(0.61)
(1.52)(1.52)
G3VM-61BR
8.3 to 8.8
2.54 2.54
1.5
1.3
G3VM-61ER
20 MOS FET Relays G3VM-61BR/ER
Absolute Maximum Ratings (Ta = 25°C)
Electrical Characteristics (Ta = 25°C)
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item Symbol Rating Unit Measurement Conditions
Input LED forward current IF30 mA
Repetitive peak LED forward
current
IFP 1 A 100 μs pulses, 100 pps
LED forward current reduction
rate
Δ IF/°C0.3 mA/°CT
a 25°C
LED reverse voltage VR5V
Connection temperature Tj125 °C
Output Load voltage (AC peak/DC) VOFF 60 V
Continuous load current IO2,500 mA
ON current reduction rate Δ ION/°C22 mA/°CT
a 25°C
Connection temperature Tj125 °C
Dielectric strength between input and
output (See note 1.)
VI-O 2,500 Vrms AC for 1 min
Operating temperature Ta20 to +85 °C With no icing or condensation
Storage temperature Tstg 40 to +125 °C With no icing or condensation
Soldering temperature (10 s) --- 260 °C10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Item Symbol Mini-
mum Typical Maxi-
mum Unit Measurement
conditions
Input LED forward voltage VF1.18 1.33 1.48 V IF = 10 mA
Reverse current IR--- --- 10 μAV
R = 5 V
Capacity between terminals CT--- 70 --- pF V = 0, f = 1 MHz
Trigger LED forward current IFT --- 1.0 3 mA IO = 1 A
Output Maximum resistance with output ON RON --- 0.065 0.1 ΩIF = 10 mA, IO = 2 A
Current leakage when the relay is open ILEAK --- 1.0 10 nA VOFF = 60 V
Capacity between terminals COFF --- 400 600 pF V = 0, f = 1MHz
Capacity between I/O terminals CI-O --- 0.8 --- pF f = 1 MHz, Vs = 0 V
Insulation resistance RI-O 1,000 --- --- MΩVI-O = 500 VDC,
RoH 60%
Tu r n - O N t i m e tON --- 1.0 1.5 ms IF = 10 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
Turn-OFF time tOFF --- 0.2 0.4 ms
V
OUT
I
F
t
ON
t
OFF
10% 90%
I
F
1
2
6
4
R
L
V
DD
V
OU
Note: 2. Turn-ON and Turn-OFF
Times
Item Symbol Minimum Typical Maximum Unit
Load voltage (AC peak/DC) VDD --- --- 48 V
Operating LED forward current IF10 --- 20 mA
Continuous load current (AC peak/DC) IO--- --- 2,500 mA
Operating temperature Ta25 --- 60 °C
MOS FET Relays G3VM-61BR/ER 21
Engineering Data
LED forward current vs.
Ambient temperature
IF - Ta
Continuous load current vs.
Ambient temperature
IO - Ta
LED forward current vs.
LED forward voltage
IF - VF
LED forward current I
F
(mA)
-20 0 20 40 60 80 100 120
0
10
20
30
40
50
Continuous load current I
O
(A)
-20 0 20 40 60 80 100 120
0
1
2
3
4
LED forward current I
F
(mA)
Ambient temperature Ta ()
Ambient temperature Taഒ
LED forward voltage V
F
(V)
Continuous load current vs.
On-state voltage
IO - VON
On-state resistance vs.
Ambient temperature
RON - Ta
Trigger LED forward current vs.
Ambient temperature
IFT - Ta
Continuous load current I
O
(A)
On-state resistance R
ON
(mΩ)
Trigger LED forward current I
FT
(mA)
On-state voltage V
ON
(mV
)
Ambient temperature Ta ()
Ambient temperature Ta ()
Turn ON, Turn OFF time vs.
LED forward current
tON, tOFF - IF
Turn ON, Turn OFF time vs.
Ambient temperature
tON, tOFF - Ta
Current leakage vs.
Ambient temperature
I LEAK - Ta
Turn ON, Turn OFF time t
ON
, t
OFF
(μS)
Turn ON, Turn OFF time t
ON
, t
OFF
(μS)
Current leakage I
LEAK
(nA)
LED forward current I
F
(mA)
Ambient temperature Ta (ഒ
Ambient temperature Ta ()
0.6 0.8 1 1.2 1.4 1.6 1.8
0.1
1
10
100
0.3
0.5
3
5
50
30
0.6 0.8 1 1.2 1.4 1.6 1.8
0.1
1
10
100
0.3
0.5
3
5
50
30
-20 0 20 40 60 80 100
0
1
2
3
4
5
-20 0 20 40 60 80 100
0
1
2
3
4
5
-20 0 20 40 60 80 100
0
50
100
150
200
-20 0 20 40 60 80 100
0
50
100
150
200
-150 -100 -50 0 50 100 150
-3
-2
-1
0
1
2
3
-150 -100 -50 0 50 100 150
-3
-2
-1
0
1
2
3
-20 0 20 40 60 80 100
1
10
100
1000
-20 0 20 40 60 80 100
1
10
100
1000
-20 020
40 60 80 100
1000
10000
30
100
300
3000
30000
-20 020
40 60 80 100
1000
10000
30
100
300
3000
30000
0102030
100
1000
10000
300
3000
30000
300102030
100
1000
10000
300
3000
30000
30
Ta = 2 5 °C
Ta = 2 5 °C
IF = 10 mA
IO = 2 A
IF = 10 mA
IO = 2 A
Ta = 25
VDD = 20 V, RL = 200 Ω
VDD = 20 V
RL = 200 Ω, I F = 5 mA VOFF = 60 V
t OFF
t ON t OFF
t ON
MOS FET Relays G3VM-61BR/ER
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No. X302-E-1 Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
12/10 Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.