ASoftline Matt
BSplash resistant (with Arcshield)
HSlotted (for custom Adaptors)
not momentary
VCurved Matt or gloss
WSplash resistant (with Arcshield)
XTwo colour Matt
ON - OFF only (not momentary)
FFlat lens Gloss (0430 only)
ASoftline lens Matt (0430 only)
as F but with raised profile
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, VOLTAGE ETC BioCote
C 1300 A L
---
B
tel: +44 (0)20 8979 3232 Arcolectric email:
europe@elektron-technology.com
Standard rocker switch
Non-illuminated
1300 high inrush current
Choice of switching
circuits including 3
position
Choice of bezel styles
Choice of panel cut outs
Matching indicator
Single pole
Splash resistant option
BioCote antimicrobial
option
Panel cut out A style:
27.3 x 12.3mm
0430
X terminal N/A
rocker
switches
22
ON - OFF
1500 Standard & 1300 High Inrush Switches 150A to EN61058-1 and 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 1
TERMINAL
Standard
1500
ON - OFF
(momentary ON)
1501
HP rating N/A
C
6.3 x 0.8
H
4.8 x 0.8*
K
2.8 x 0.8*
T
Solder
U
Right angle “T” solder terminal
X
PCB 0.8Sq*
*N/A for 1300 series
9.1
7.0
Ø2.1
1500 Series 16(4)A 250Vac T125
UL CSA 16A Non Ind 250Vac, (2 posn) 250Vac 1hp, 125Vac
1/2hp, (3 posn) 250Vac 1/2hp, 125Vac 1/4hp
UL 10A 14Vdc T’ (1500 and 1510 only)
UL 85˚C, file E45221, CSA file LR10990
10A 24Vdc Indicative rating only
1300 series 16(6)A 250Vac T125 5E4 (50,000 Ops.)
150A Inrush to EN61058-1
UL CSA 20A 250Vac 1hp, 125Vac 1/2hp
UL 85˚C, file E45221, CSA file LR10990
20A 24Vdc Indicative rating only
BioCote antimicrobial additive. Independently verified
to ISO22196:2007.
3mm contact gap except if marked µ.
Technical data on pages 4 & 5 (switches), 6 (indicators).
9.1
9.1
2.0
1.2
3.2
Ø2.1
9.1
4.0
12 3
ON - OFF
(momentary OFF)
1502
HP rating N/A
ON - ON
1510 µ
HP rating N/A
ON - ON
(momentary 1 side)
1511 µ
HP rating N/A
ON - OFF - ON
1520 µ
125V & 250V 1/2 HP
H terminal rated
T100 only
ON - OFF - ON
(momentary 1 side)
1521 µ
HP rating N/A
H terminal rated
T100 only
ON - OFF - ON
(momentary 2 sides)
1522 µ
HP rating N/A
H terminal rated
T100 only
Indicator
Technical data on page 6
Matt
Matt
High Inrush
1300
‘L body only
Approvals apply to C & T
terminals only
Approvals and specifications
In house test:
In house test:
07-Cat171_P018-029|Series 1350,1500 and 6000:Catalogue No.171_Oct 2011 16/11/11 10:03 Page 22