Effective December 2015 Supersedes April 2014 Technical Data 2020 BUSSMANN SERIES KLM 1332 x 1-12 600Vac/dc fast-acting supplemental fuses Catalog symbol / color code: * Dimensions - in (mm): KLM - Black (600Vac/dc max) Description: For superior protection, Eaton Bussmann Division recommends upgrading to Low-PeakTM Class CC fuses. See data sheet No. 1023. For protecting DC photovoltaic systems, Eaton Bussmann Division recommends using PVM 10x30mm PV fuses. See data sheet No. 10121. Specifications: Ratings Interrupting rating at rated voltage 600 Fuse amp 600 Vac Vdc range 1/10 to 30 100kA 50kA 600Vac/dc 1 to 30A Agency information CSA(R) X Opening time 4 hours minimum AC opens within 1 hour Qty. 10 Features * Color coded for 600Vac/dc * A full range DC supplemental fuse * Melamine tube construction * Nickel-plated endcaps. * DC control circuits requiring fast-acting fuses * PV systems up to 600Vdc Catalog Description symbol Blocks BMM 1-, 2-and 3-pole modular blocks with optional covers Data sheet No. 10235 DIN-Rail holders / switches * CE, RoHS compliant * UL Listed: Std. 248-14, Guide JDYX, File E19180 * CSA Certified, C22.2 No. 248. 14, Class 1422-01, File 53787 Catalog numbers (amps) KLM-1 KLM-1-14 KLM-1-12 KLM-2 KLM-2-12 KLM-3 KLM-4 Amps 1/10 to 30 Recommended fuse blocks/fuse holders: Agency information KLM-110 KLM-18 KLM-210 KLM-14 KLM-310 KLM-12 KLM-34 Carton quantity Typical applications UL(R) X Electrical characteristics % of amp rating 110% 135% 1.5" (38.1) 0.41" (10.3) Fast-acting supplemental fuse. KLM-5 KLM-6 KLM-7 KLM-8 KLM-9 KLM-10 KLM-12 KLM-15 KLM-20 KLM-25 KLM-30 CCP-_-30M 1-, 2- and 3-pole switch 1157 CHM 1-, 2- and 3-pole 3185 Optima NG 3-pole protection module 1109 Optima 3-pole holder 1102 Optima 3-pole holder + switch 1103 Panel mount holders HPM and HPM-D 1-pole holder 2112 HPC-D 1-pole holder 2109 HPS2 2-pole holder 2140 HPF, HPF-C and HPF-WT 1-pole holder 2114 HPS 1-pole holder 2113 HPG and HPD 1-pole holder 2108 In-line holders HEB 1-pole holder 2127 HEX 2-pole holder 2126 PCB fuseclips 2132 Fuseclips 1A3400, 5956 and 5960 Fuse covers CVR(I)-CCM(-QC) Finger-safe fuse cover 10235 Technical Data 2020 KLM 600Vac/dc fast-acting supplemental fuses Effective December 2015 30 A 15 A 20 A 8A 10 A 5A 3A 100 3/4 A Time-current characteristic curves - total clearing: Amp rating Amp Rating Time in seconds Time in Seconds 10 1 Current in amps Current in Amps 1000 10 1 0.01 100 0.1 The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States Eaton.com/bussmannseries (c) 2015 Eaton All Rights Reserved Printed in USA Publication No. 2020 - BU-SB14289 December 2015 For Eaton's Bussmann series product information, call 1-855-287-7626 or visit: Eaton.com/bussmannseries Eaton, Bussmann and Low-Peak are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. CSA is a registered trademark of the Canadian Standards Group. UL is a registered trademark of the Underwriters Laboratories, Inc. Follow us on social media to get the latest product and support information.