https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Feed-through terminal block, nom. voltage: 800 V, nominal current: 24 A, connection method: Spring-cage connection, number of connections: 2, cross section: 0.08 mm-4 mm, AWG:28-12, width: 5.2 mm, color: blue, mounting type: NS 35/7,5, NS 35/15 Your advantages User-friendly wiring thanks to front connection Angled conductor entry for use in flat terminal boxes Large space saving when used in concealed wiring systems Feed-through terminal blocks with 2, 3 or 4 connections have the same shape Key Commercial Data Packing unit 1 pc Minimum order quantity 50 pc GTIN GTIN 4017918876951 Weight per Piece (excluding packing) 6.920 g Custom tariff number 85369010 Country of origin Germany Technical data General Number of levels 1 Number of connections 2 Potentials 1 Nominal cross section 2.5 mm 12/06/2020Page1/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Technical data General Color blue Insulating material PA Flammability rating according to UL 94 V0 Rated surge voltage 8 kV Degree of pollution 3 Overvoltage category III Insulating material group I Maximum power dissipation for nominal condition 0.77 W Maximum load current 31 A (with 4mm conductor cross section) Nominal current IN 24 A Nominal voltage UN 800 V Open side panel Yes Ambient temperature (operation) -60 C ... 105 C () Ambient temperature (storage/transport) -25 C ... 60 C () Permissible humidity (storage/transport) 30 % ... 70 % Ambient temperature (assembly) -5 C ... 70 C Ambient temperature (actuation) -5 C ... 70 C Relative insulation material temperature index (Elec., UL 746 B) 130 C Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 C Static insulating material application in cold -60 C Surface flammability NFPA 130 (ASTM E 162) passed Specific optical density of smoke NFPA 130 (ASTM E 662) passed Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg Smoke gas toxicity NFPA 130 (SMP 800C) passed Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3 Dimensions Width 5.2 mm End cover width 2.2 mm Length 50.8 mm Height NS 35/7,5 43 mm Height NS 35/15 50.5 mm Connection data Connection 1 level 12/06/2020Page2/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Technical data Connection data Connection method Spring-cage connection Stripping length 8 mm ... 10 mm Connection in acc. with standard IEC60947-7-1 Conductor cross section solid min. 0.08 mm Conductor cross section solid max. 4 mm Conductor cross section AWG min. 28 Conductor cross section AWG max. 12 Conductor cross section flexible min. 0.08 mm Conductor cross section flexible max. 2.5 mm Min. AWG conductor cross section, flexible 28 Max. AWG conductor cross section, flexible 14 Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm Conductor cross section flexible, with ferrule with plastic sleeve min. 0.14 mm Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 0.5 mm Connection in acc. with standard IEC/EN60079-7 Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 4 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 2.5 mm Internal cylindrical gage A3 Standards and Regulations Connection in acc. with standard CSA IEC60947-7-1 IEC/EN60079-7 Flammability rating according to UL 94 V0 Environmental Product Compliance China RoHS Environmentally friendly use period: unlimited = EFUP-e No hazardous substances above threshold values Drawings 12/06/2020Page3/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Circuit diagram Classifications eCl@ss eCl@ss 10.0.1 27141120 eCl@ss 11.0 27141120 eCl@ss 4.0 27141100 eCl@ss 4.1 27141100 eCl@ss 5.0 27141100 eCl@ss 5.1 27141100 eCl@ss 6.0 27141100 eCl@ss 7.0 27141120 eCl@ss 8.0 27141120 eCl@ss 9.0 27141120 ETIM ETIM 2.0 EC000897 ETIM 3.0 EC000897 ETIM 4.0 EC000897 ETIM 5.0 EC000897 ETIM 6.0 EC000897 ETIM 7.0 EC000897 UNSPSC UNSPSC 6.01 30211811 UNSPSC 7.0901 39121410 UNSPSC 11 39121410 UNSPSC 12.01 39121410 UNSPSC 13.2 39121410 UNSPSC 18.0 39121410 UNSPSC 19.0 39121410 UNSPSC 20.0 39121410 UNSPSC 21.0 39121410 Approvals Approvals 12/06/2020Page4/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Approvals Approvals DNV GL / CSA / KR / UL Recognized / cUL Recognized / IECEE CB Scheme / EAC / RS / EAC / VDE Zeichengenehmigung / cULus Recognized Ex Approvals IECEx / ATEX / EAC Ex Approval details DNV GL https://approvalfinder.dnvgl.com/ TAE00001CS CSA http://www.csagroup.org/services-industries/product-listing/ 13631 B C Nominal voltage UN 600 V 600 V Nominal current IN 20 A 20 A mm/AWG/kcmil 28-12 28-12 KR http://www.krs.co.kr/eng/main/main.aspx HMB36894-EL001 UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 60425 B C Nominal voltage UN 600 V 600 V Nominal current IN 20 A 20 A mm/AWG/kcmil 28-12 28-12 cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm B C Nominal voltage UN 600 V 600 V FILE E 60425 12/06/2020Page5/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Approvals B C Nominal current IN 20 A 20 A mm/AWG/kcmil 28-12 28-12 IECEE CB Scheme http://www.iecee.org/ DE1-63032 EAC EAC-Zulassung RS http://www.rs-head.spb.ru/en/index.php 17.00013.272 EAC RU CDE.A*30.B.01742 VDE Zeichengenehmigung http://www2.vde.com/de/Institut/Online-Service/ VDE-gepruefteProdukte/Seiten/Online-Suche.aspx 40009033 Nominal voltage UN 800 V Nominal current IN 24 A mm/AWG/kcmil 0.2-2.5 cULus Recognized Accessories Accessories Bridge 12/06/2020Page6/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Wire bridge-FBSW 2-5/250MM-3030172 Wire bridge, length: 250 mm, width: 5.1 mm, number of positions: 1, color: red/black Wire bridge-FBSW 2-5/60MM-3030170 Wire bridge, length: 60 mm, width: 5.1 mm, number of positions: 1, color: red/black Wire bridge-FBSW 2-5/110MM-3030171 Wire bridge, length: 110 mm, width: 5.1 mm, number of positions: 1, color: red/black Wire bridge-FBSW 2-5/250MM-3030172 Wire bridge, length: 250 mm, width: 5.1 mm, number of positions: 1, color: red/black Wire bridge-FBSW 2-5/60MM-3030170 Wire bridge, length: 60 mm, width: 5.1 mm, number of positions: 1, color: red/black 12/06/2020Page7/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Wire bridge-FBSW 2-5/110MM-3030171 Wire bridge, length: 110 mm, width: 5.1 mm, number of positions: 1, color: red/black Component plug terminal block Component connector-P-CO 2-5 R47K-3032447 Component connector, with 47 kOhm resistance for wire-break monitoring, pitch: 5.2 mm, length: 8.9 mm, width: 4.1 mm, height: 34.8 mm, number of positions: 2, color: black Cover Group cover marker-BST 2,5-3061282 Cover for actuation shaft, 5-pos., for spring-cage terminal blocks with width of 5.2 mm DIN rail DIN rail perforated-NS 35/ 7,5 PERF 2000MM-0801733 DIN rail perforated, Standard profile, width:35 mm, height:7.5 mm, acc. to EN 60715, material:Steel, galvanized, passivated with a thick layer, length:2000 mm, color:silver 12/06/2020Page8/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories DIN rail, unperforated-NS 35/ 7,5 UNPERF 2000MM-0801681 DIN rail, unperforated, Standard profile, width:35 mm, height:7.5 mm, acc. to EN 60715, material:Steel, galvanized, passivated with a thick layer, length:2000 mm, color:silver DIN rail perforated-NS 35/ 7,5 WH PERF 2000MM-1204119 DIN rail perforated, Standard profile, width:35 mm, height:7.5 mm, acc. to EN 60715, material:Steel, Galvanized, white passivated, length:2000 mm, color:silver DIN rail, unperforated-NS 35/ 7,5 WH UNPERF 2000MM-1204122 DIN rail, unperforated, Standard profile, width:35 mm, height:7.5 mm, acc. to EN 60715, material:Steel, Galvanized, white passivated, length:2000 mm, color:silver DIN rail, unperforated-NS 35/ 7,5 AL UNPERF 2000MM-0801704 DIN rail, unperforated, Standard profile, width:35 mm, height:7.5 mm, acc. to EN 60715, material:Aluminum, uncoated, length:2000 mm, color:silver DIN rail perforated-NS 35/ 7,5 ZN PERF 2000MM-1206421 DIN rail perforated, Standard profile, width:35 mm, height:7.5 mm, acc. to EN 60715, material:Steel, galvanized, length:2000 mm, color:silver 12/06/2020Page9/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories DIN rail, unperforated-NS 35/ 7,5 ZN UNPERF 2000MM-1206434 DIN rail, unperforated, Standard profile, width:35 mm, height:7.5 mm, acc. to EN 60715, material:Steel, galvanized, length:2000 mm, color:silver DIN rail, unperforated-NS 35/ 7,5 CU UNPERF 2000MM-0801762 DIN rail, unperforated, Standard profile, width:35 mm, height:7.5 mm, acc. to EN 60715, material:Copper, uncoated, length:2000 mm, color:copper-colored End cap-NS 35/ 7,5 CAP-1206560 DIN rail end piece, for DIN rail NS 35/7.5 Documentation Mounting material-ST-IL-3039900 Operating decal for the ST terminal block End block End clamp-E/AL-NS 35-1201662 End clamp, for end support of UKH 50 to UKH 240, is pushed onto DIN rail NS 35 and fixed with 2 screws, width: 10 mm, color: aluminum 12/06/2020Page10/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories End cover End cover-D-STS 2,5-3031762 End cover, length: 51 mm, width: 2.2 mm, height: 43 mm, color: gray Filler plug Filler plugs-CEC 2,5-3062757 Cover for conductor shaft, 10-pos., for spring cage terminal blocks (ST) and terminal blocks with push-in technology (PT) with a width of 5.2 mm Insulating sleeve Insulating sleeve-MPS-IH WH-0201663 Insulating sleeve, color: white Insulating sleeve-MPS-IH RD-0201676 Insulating sleeve, color: red 12/06/2020Page11/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Insulating sleeve-MPS-IH BU-0201689 Insulating sleeve, color: blue Insulating sleeve-MPS-IH YE-0201692 Insulating sleeve, color: yellow Insulating sleeve-MPS-IH GN-0201702 Insulating sleeve, color: green Insulating sleeve-MPS-IH GY-0201728 Insulating sleeve, color: gray Insulating sleeve-MPS-IH BK-0201731 Insulating sleeve, color: black 12/06/2020Page12/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Insulating sleeve-ISH 2,5/0,2-3002843 Insulating sleeve, color: white Insulating sleeve-ISH 2,5/0,5-3002856 Insulating sleeve, color: gray Insulating sleeve-ISH 2,5/1,0-3002869 Insulating sleeve, color: black Jumper Plug-in bridge-FBS 2-5-3030161 Plug-in bridge, pitch: 5.2 mm, length: 22.7 mm, width: 9 mm, number of positions: 2, color: red Plug-in bridge-FBS 3-5-3030174 Plug-in bridge, pitch: 5.2 mm, length: 22.7 mm, width: 14.2 mm, number of positions: 3, color: red 12/06/2020Page13/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Plug-in bridge-FBS 4-5-3030187 Plug-in bridge, pitch: 5.2 mm, length: 22.7 mm, width: 19.4 mm, number of positions: 4, color: red Plug-in bridge-FBS 5-5-3030190 Plug-in bridge, pitch: 5.2 mm, length: 23 mm, width: 24.6 mm, number of positions: 5, color: red Plug-in bridge-FBS 10-5-3030213 Plug-in bridge, pitch: 5.2 mm, length: 22.7 mm, width: 50.6 mm, number of positions: 10, color: red Plug-in bridge-FBS 20-5-3030226 Plug-in bridge, pitch: 5.2 mm, number of positions: 20, color: red Plug-in bridge-FBS 50-5-3038930 Plug-in bridge, pitch: 5.2 mm, number of positions: 50, color: red 12/06/2020Page14/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Plug-in bridge-FBSR 2-5-3033702 Plug-in bridge, pitch: 5.2 mm, number of positions: 2, color: red Plug-in bridge-FBSR 3-5-3001591 Plug-in bridge, pitch: 5.2 mm, number of positions: 3, color: red Plug-in bridge-FBSR 4-5-3001592 Plug-in bridge, pitch: 5.2 mm, number of positions: 4, color: red Plug-in bridge-FBSR 5-5-3001593 Plug-in bridge, pitch: 5.2 mm, number of positions: 5, color: red Plug-in bridge-FBSR 10-5-3033710 Plug-in bridge, pitch: 5.2 mm, number of positions: 10, color: red 12/06/2020Page15/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Plug-in bridge-FBS 2-5 BU-3036877 Plug-in bridge, pitch: 5.2 mm, number of positions: 2, color: blue Plug-in bridge-FBS 3-5 BU-3036880 Plug-in bridge, pitch: 5.2 mm, number of positions: 3, color: blue Plug-in bridge-FBS 4-5 BU-3036893 Plug-in bridge, pitch: 5.2 mm, number of positions: 4, color: blue Plug-in bridge-FBS 5-5 BU-3036903 Plug-in bridge, pitch: 5.2 mm, number of positions: 5, color: blue Plug-in bridge-FBS 10-5 BU-3036916 Plug-in bridge, pitch: 5.2 mm, number of positions: 10, color: blue 12/06/2020Page16/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Plug-in bridge-FBS 20-5 BU-3036929 Plug-in bridge, pitch: 5.2 mm, number of positions: 20, color: blue Plug-in bridge-FBS 50-5 BU-3032114 Plug-in bridge, pitch: 5.2 mm, number of positions: 50, color: blue Labeled terminal marker Warning cover-WST 2,5-3030941 Warning cover, 5-pos., for terminal width: 5.2 mm Zack marker strip-ZB 5 CUS-0824962 Zack marker strip, can be ordered: Strip, white, labeled according to customer specifications, mounting type: snap into tall marker groove, for terminal block width: 5.2 mm, lettering field size: 5.15 x 10.5 mm, Number of individual labels: 10 Zack marker strip-ZB 5,LGS:FORTL.ZAHLEN-1050017 Zack marker strip, Strip, white, labeled, printed horizontally: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 491 ... 500, mounting type: snap into tall marker groove, for terminal block width: 5.2 mm, lettering field size: 5.15 x 10.5 mm, Number of individual labels: 10 12/06/2020Page17/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Zack marker strip-ZB 5,QR:FORTL.ZAHLEN-1050020 Zack marker strip, white, Printed vertically: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 491 ... 500, mounting type: snap into tall marker groove, for terminal block width: 5.2 mm, lettering field size: 5.15 x 10.5 mm Zack marker strip-ZB 5,LGS:GLEICHE ZAHLEN-1050033 Zack marker strip, Strip, white, labeled, can be labeled with: CMS-P1-PLOTTER, printed horizontally: Identical numbers 1 or 2, etc. up to 100, mounting type: snap into tall marker groove, for terminal block width: 5.2 mm, lettering field size: 5.15 x 10.5 mm, Number of individual labels: 10 Zack marker strip-ZB 5,LGS:L1-N,PE-1050415 Zack marker strip, Strip, white, labeled, horizontal: L1, L2, L3, N, PE, L1, L2, L3, N, PE, mounting type: snap into tall marker groove, for terminal block width: 5.2 mm, lettering field size: 5.15 x 10.5 mm, Number of individual labels: 10 Marker for terminal blocks-UC-TM 5 CUS-0824581 Marker for terminal blocks, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: snap into tall marker groove, for terminal block width: 5.2 mm, lettering field size: 10.5 x 4.6 mm, Number of individual labels: 96 Marker for terminal blocks-UCT-TM 5 CUS-0829595 Marker for terminal blocks, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: snap into tall marker groove, for terminal block width: 5.2 mm, lettering field size: 4.6 x 10.5 mm, Number of individual labels: 72 12/06/2020Page18/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Zack Marker strip, flat-ZBF 5 CUS-0825025 Zack Marker strip, flat, can be ordered: Strip, white, labeled according to customer specifications, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10 Zack Marker strip, flat-ZBF 5,LGS:FORTL.ZAHLEN-0808671 Zack Marker strip, flat, Strip, white, labeled, printed horizontally: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 491 ... 500, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10 Zack Marker strip, flat-ZBF 5,QR:FORTL.ZAHLEN-0808697 Zack Marker strip, flat, Strip, white, labeled, Printed vertically: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 91 ... 100, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10 Zack Marker strip, flat-ZBF 5,LGS:GERADE ZAHLEN-0810821 Zack Marker strip, flat, Strip, white, labeled, printed horizontally: consecutive numbers 2 ... 20, 22 ... 40, etc. up to 82 ... 100, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10 Zack Marker strip, flat-ZBF 5,LGS:UNGERADE ZAHLEN-0810863 Zack Marker strip, flat, Strip, white, labeled, printed horizontally: Odd numbers 1 - 19, 21 - 39, etc. up to 81 - 99, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10 12/06/2020Page19/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Marker for terminal blocks-UC-TMF 5 CUS-0824638 Marker for terminal blocks, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: snap into flat marker groove, for terminal block width: 5.2 mm, lettering field size: 4.6 x 5.1 mm, Number of individual labels: 96 Marker for terminal blocks-UCT-TMF 5 CUS-0829658 Marker for terminal blocks, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: snap into flat marker groove, for terminal block width: 5.2 mm, lettering field size: 4.4 x 4.7 mm, Number of individual labels: 72 Marker pen Marker pen-X-PEN 0,35-0811228 Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm Marker pen-B-STIFT-1051993 Marker pen, for manual labeling of unprinted Zack strips, smear-proof and waterproof, line thickness 0.5 mm Partition plate Spacer plate-DP PS-5-3036725 Spacer plate, length: 22.4 mm, width: 5.2 mm, height: 29 mm, number of positions: 1, color: red 12/06/2020Page20/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Screwdriver tools Screwdriver-SZF 1-0,6X3,5-1204517 Actuation tool, for ST terminal blocks, also suitable for use as a bladed screwdriver, size: 0.6 x 3.5 x 100 mm, 2component grip, with non-slip grip Actuation tool-ST-BW-1207608 Actuation tool, for all 2.5 mm - 4.0 mm spring-cages Terminal marking Zack marker strip-ZB 5 :UNBEDRUCKT-1050004 Zack marker strip, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into tall marker groove, for terminal block width: 5.2 mm, lettering field size: 5.1 x 10.5 mm, Number of individual labels: 10 Marker for terminal blocks-UC-TM 5-0818108 Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: BLUEMARKIDCOLOR, BLUEMARKID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into tall marker groove, for terminal block width: 5.2 mm, lettering field size: 10.5 x 4.6 mm, Number of individual labels: 96 12/06/2020Page21/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Marker for terminal blocks-UCT-TM 5-0828734 Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: TOPMARKNEO, TOPMARK LASER, BLUEMARKIDCOLOR, BLUEMARKID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: snap into tall marker groove, for terminal block width: 5.2 mm, lettering field size: 4.6 x 10.5 mm, Number of individual labels: 72 Zack Marker strip, flat-ZBF 5:UNBEDRUCKT-0808642 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.1 x 5.2 mm, Number of individual labels: 10 Marker for terminal blocks-UC-TMF 5-0818153 Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: BLUEMARKIDCOLOR, BLUEMARKID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into flat marker groove, for terminal block width: 5.2 mm, lettering field size: 4.6 x 5.1 mm, Number of individual labels: 96 Marker for terminal blocks-UCT-TMF 5-0828744 Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: TOPMARKNEO, TOPMARK LASER, BLUEMARKIDCOLOR, BLUEMARKID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: snap into flat marker groove, for terminal block width: 5.2 mm, lettering field size: 4.4 x 4.7 mm, Number of individual labels: 72 Test plug terminal block Test plugs-MPS-MT-0201744 Test plugs, with solder connection up to 1 mm conductor cross section, color: gray 12/06/2020Page22/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Test plugs-PS-5-3030983 Test plugs, Modular test plug, color: red Test plugs-PS-5/2,3MM RD-3038723 Test plugs, color: red Test socket Test adapter-PAI-4-FIX-5/6 BU-3035975 4 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitch Test adapter-PAI-4-FIX-5/6 OG-3035974 4 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitch Test adapter-PAI-4-FIX-5/6 YE-3035977 4 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitch 12/06/2020Page23/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Test adapter-PAI-4-FIX-5/6 RD-3035976 4 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitch Test adapter-PAI-4-FIX-5/6 GN-3035978 4 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitch Test adapter-PAI-4-FIX-5/6 BK-3035980 4 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitch Test adapter-PAI-4-FIX-5/6 GY-3035982 4 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitch Test adapter-PAI-4-FIX-5/6 VT-3035979 4 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitch 12/06/2020Page24/25 https://www.phoenixcontact.com/us/products/3036408 Feed-through terminal block-STS 2,5 BU-3036408 Accessories Test adapter-PAI-4-FIX-5/6 BN-3035981 4 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitch Test adapter-PAI-4-FIX-5/6 WH-3035983 4 mm test adapter, for terminal blocks with 5.2 mm and 6.2 mm pitch Phoenix Contact 2020 (c) - all rights reserved http://www.phoenixcontact.com 12/06/2020Page25/25