Switches & Pilot Devices Switches & Pilot Devices o30mm - TWTD Series Relays & Sockets Signaling Lights TWTD Series -- Full Size NEMA Pushbuttons TWTD Series: Heavy duty switches built to last Key features: The rugged series of TWTD switches offers both variety and durability in an attractive design. Timers * Variety of button sizes up to 2 9/16" (65mm) * Rugged construction includes chrome plated zinc locking ring die cast zinc mounting threads, screw mounted contact blocks * LED or incandescent illumination The TWTD series also offers either LED or incandescent illumination in full voltage and transformer models. * Transformer or full voltage * Transparent contact windows Transparent contact windows allow the viewing of IDEC's self cleaning slowmake/slow-break contacts. * Slow make, double break self-cleaning contacts Regardless of your switching needs, the TWTD series provides the kind of long lasting, industrial strength quality you've come to expect from IDEC. * Modular construction for maximum flexibility Contactors With button sizes up to 2 9/16" (65mm), chrome plated zinc locking rings, die cast zinc mounting threads, steel anti-rotation rings, and self cleaning contacts, the TWTDs are here to stay. * Double nickel plated terminal screws * Available assembled or as sub-components * Type 4x and IP65 watertight/oiltight panel Terminal Blocks * Large M3.5 screw terminals with captive sems plate File No. LR21451 Ref No. 117617MC Certificate No. 2005010305145658 Circuit Breakers UL Listed File No. E68961 720 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - TWTD Series Switches & Pilot Devices Specifications EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14 Approvals CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TUV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) Operating Temperature Operation: -25 to +50C (without freezing) Storage: -40 to +70C (without freezing) Vibration Resistance 10 to 55Hz, 98m/sec2 (10g) conforming to IEC6068-2-6 Shock Resistance 980m/sec2 (100g) conforming to IEC6068-2-7 Electric Shock Protection Class 0 conforming to IEC60536 Degree of Protection IP65 (from front of the panel) (conforming to IEC60529) IP54 (key switches) Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (conforming to NEMA ICS6-110) Mechanical Life Momentary pushbuttons: 5,000,000 (900 operations per hour) All other switches: 500,000 Pollution Degree (conforming to IEC60947-1) 3 for switches not using a transformer 2 for switches using a transformer Signaling Lights Conforming to Standards Relays & Sockets Mechanical-Electrical Specifications AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB) DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC) DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB) Rated Insulation Voltage 600V Rated Switching Overvoltage Less than 4kV, conforming to IEC60947-1 Rated Impulse Withstanding Voltage 4kV for contact circuit 2.5kV for lamp circuit Rated Thermal Current 10 Amp Minimum Switching Capacity 5 mA at 3V AC/DC Contact Operation Slow break NC or NO, self-cleaning Operating Force Flush and extended pushbuttons--with 1NO or 1NC contact: 6.22N (momentary), 7.02N (maintained) Additional contacts--1NO or 1NC: +3.2N (momentary), + 3.3N (maintained) Terminal Referencing Conforming to CENELEC EN50005 Recommended Terminal Torque 0.8 N m (7.1 in lb.) External Short-Circuit Protection 10A 250V fuse conforming to IEC60269-1 Applicable Wire Size Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG Contact Resistance Initial contact resistance of 50m or less Contact Gap 4mm (NO and NC) 2mm (NO-EM and NC-LB) Lamp Ratings Incandescent: 1 W LEDs: 6V: 17mA, 12V: 11mA, 24V: 11mA, / 120, 240V: 10mA Maximum Inrush Current 40 A (40 msec) Contact Material Silver Timers Rated Operational Characteristics Contactors Terminal Blocks Contact Ratings AC-15 (A600) Contact Ratings by Utilization Category IEC 60947-5-1 DC-13 (P600) Contact Ratings by Utilization Category AC 50/60 Hz Operation Current DC 1705151134 24V 48V 50V 110V 220V 440V AC-12 Control of resistive loads & solid state loads 10A -- 10A 10A 6A 2A AC-15 Control of electromagnetic loads (> 72VA) 10A -- 7A 5A 3A 1A DC-12 Control of resistive loads & solid state loads 8A 5A -- 2.2A 1.1A -- DC-13 Control of electromagnets 5A 2A -- 1.1A 0.6A -- 800-262-IDEC (4332) * USA & Canada Circuit Breakers Operational Voltage 721 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWTD Series Timers Relays & Sockets Signaling Lights Non-Illuminated Pushbuttons (Assembled) Assembled Pushbuttons A B ( ) D 1 10 Function Button Color B: O: V: Y: B: Black R: Red Momentary Maintained Pushlock Turn Reset Push-Pull G: Green S: Blue W: White Y: Yellow Contact Arrangement 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO-1NC 22: 2NO-2NC Bezel Shape Blank: Octagonal F: Full Shroud G: Mushroom Shroud P: Neoprene Boot Button Shape 1: 2: 3: 4: Series Designation Contactors N - R D: TWTD Series Flush Extended Mushroom o 40mm Jumbo Mushroom o 65mm Circuit Breakers Terminal Blocks 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Custom contact configurations available, contact IDEC for details. 722 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - TWTD Series Switches & Pilot Devices Non-Illuminated Pushbuttons (Assembled) Non-Illuminated Pushbuttons Style j Button Color Codes AOD110N-j AOD101N-j AOD111N-j AOD120N-j AOD102N-j 1NO 1NC 1NO-1NC 2NO 2NC ABD210N-j ABD201N-j ABD211N-j ABD220N-j ABD202N-j AOD210N-j AOD201N-j AOD211N-j AOD220N-j AOD202N-j Extended with Neoprene Boot 1NO 1NC 1NO-1NC 2NO 2NC ABPD210N-j ABPD201N-j ABPD211N-j ABPD220N-j ABPD202N-j AOPD210N-j AOPD201N-j AOPD211N-j AOPD220N-j AOPD202N-j Recessed 1NO 1NC 1NO-1NC 2NO 2NC ABFD110N-j ABFD101N-j ABFD111N-j ABFD120N-j ABFD102N-j AOFD110N-j AOFD101N-j AOFD111N-j AOFD120N-j AOFD102N-j Extended with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABFD210N-j ABFD201N-j ABFD211N-j ABFD220N-j ABFD202N-j AOFD210N-j AOFD201N-j AOFD211N-j AOFD220N-j AOFD202N-j o 40mm Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ABD310N-j ABD301N-j ABD311N-j ABD320N-j ABD302N-j AOD310N-j AOD301N-j AOD311N-j AOD320N-j AOD302N-j o 40mm Mushroom Head with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABGD310N-j ABGD301N-j ABGD311N-j ABGD320N-j ABGD302N-j AOGD310N-j AOGD301N-j AOGD311N-j AOGD320N-j AOGD302N-j o 65mm Jumbo Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ABD410N-j ABD401N-j ABD411N-j ABD420N-j ABD402N-j AOD410N-j AOD401N-j AOD411N-j AOD420N-j AOD402N-j o 65mm Jumbo Mushroom Head with Shallow Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABGD410N-j ABGD401N-j ABGD411N-j ABGD420N-j ABGD402N-j AOGD410N-j AOGD401N-j AOGD411N-j AOGD420N-j AOGD402N-j o 65mm Jumbo Mushroom Head With Deep Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABFD410N-j ABFD401N-j ABFD411N-j ABFD420N-j ABFD402N-j AOFD410N-j AOFD401N-j AOFD411N-j AOFD420N-j AOFD402N-j Flush Extended Color Code Black B Green G Red R Blue S Yellow Y White W 1. 65mm Jumbo mushroom not available in white. 2. Neoprene boot is not available in blue or white. Terminal Blocks ABD110N-j ABD101N-j ABD111N-j ABD120N-j ABD102N-j Contactors 1NO 1NC 1NO-1NC 2NO 2NC Timers Maintained Relays & Sockets Momentary Signaling Lights Contacts 1705151134 800-262-IDEC (4332) * USA & Canada Circuit Breakers 1. In place of j, specify the Button Color Code. 2. For sub-assembly part numbers, see next page. 4. Neoprene boot available only in Black (B), Green (G), Red (R) and Yellow (Y). 723 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o30mm - TWTD Series Non-Illuminated Pushbuttons (Sub-Assembled) Contact Block Relays & Sockets Operator + Operators Part Number Maintained ABD-100 AOD-100 ABFD-200 AOFD-200 o 40mm Mushroom/o 65mm Jumbo Mushroom ABD-300 AOD-300 Complete Part AOGD-300 Contactors ABGD-300 Part Number Flush ABD1BN-j Extended ABD2BN-j o 40mm Mushroom ABD3BN-j o 65mm Jumbo Mushroom ABD4BN-j In place of j, specify the Button Color Code. (See table previous page) o 65mm Jumbo Mushroom with Shallow Shroud Terminal Blocks = Style Momentary Extended with Full Shroud o 40mm Mushroom with Full Shroud Button Buttons and Lenses Style Flush/Extended Timers + ABGD-400 AOGD-400 Contact Blocks Style o 65mm Jumbo Mushroom with Deep Shroud ABFD-400 AOFD-400 All Control Units Dummy Block Part Number 1NO 1NC BST-010 BST-001 BST-010S (early make) BST-001S (late break) BST-D Circuit Breakers 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining BST-010S and BST-001S result in overlapping contacts (remain on, or closed, when switch is moved between two positions). 724 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - TWTD Series Switches & Pilot Devices Stop Switches (Assembled) Signaling Lights A V (L) D 3 (99) 11 (D) N - R - (24V) Lamp Voltage Function (full voltage illuminated units only) V:Pushlock Turn Reset Y:Push-Pull Blank: None L: Illuminated 6V AC/DC 12V AC/DC 24V AC/DC 120V AC (LED only) 240V AC (LED only) Timers 6V: 12V: 24V: 120V: 240V: Illumination Button/Lens Color Code Series Designation Button/Lens Size 3: 40mm Mushroom Illumination Circuit Full Voltage (lamp determines voltage) 120V AC Step Down Transformer 240V AC Step Down Transformer 480V AC Step Down Transformer Contactors A: Amber G: Green R: Red S: Blue W: White Y: Yellow D: TWTD Series 99: 126: 246: 486: Relays & Sockets Assembled Stop Switches Lamp Type (illuminated units only) Blank: Incandescent D: LED Terminal Blocks Contact Arrangement 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO-1NC 22: 2NO-2NC 1705151134 800-262-IDEC (4332) * USA & Canada Circuit Breakers 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Custom contact configurations available, contact IDEC for details. 725 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWTD Series Stop Switches (Assembled) Stop Switches 3 Position Push-Pull Style Contacts o 40mm Pushlock Turn Reset Relays & Sockets Signaling Lights Non-Illuminated o 40mm Illuminated Pushlock Turn Reset Full Voltage AVLD39911nN-R-l* AVLD39920nN-R-l* AVLD39902nN-R-l* Transformer 1NO-1NC 2NO 2NC AVLD3 m 11nN-R* AVLD3 m 20nN-R* AVLD3 m 02nN-R* o 40mm Push-Pull Non-Illuminated Timers Full Voltage o 40mm Momentary Push-Pull (3-position) Contactors 1NO 1NC 1NO-1NC 2NO 2NC AYD310N-j AYD301N-j AYD311N-j AYD320N-j AYD302N-j 1NO-1NC 2NO 2NC AYLD39911nN-k-l ** AYLD39920nN-k-l ** AYLD39902nN-k-l ** Transformer 1NO-1NC 2NO 2NC AYLD3 m 11nN-k ** AYLD3 m 20nN-k ** AYLD3 m 02nN-k** Full Voltage 1NO-1NC 1NC-1LB AYLD229911nN-k-l -TK962 AYLD229902SnN-k-l-TK962 1NO-1NC 1NC-1LB AYLD22 m 11nN-k-TK962 AYLD22 m 02SnN-k-TK962 Unibody E-Stops Style o 40mm Pushlock Turn Reset (available in Red only) Illuminated o 40mm Pushlock Turn Reset (available in Red only) 1. 2. 3. 4. 5. 6. In place of j, specify the button color code In place of k, specify the lens color code. In place of l, specify the Full Voltage (lamp voltage) Code. In place of m, specify the transformer voltage code. In place of n, specify the Lamp Type code. With single unit construction, the positive action contacts are integrated in the body of the switch. This provides an extra degree of safety and reliability for critical emergency stop functions. 7. HN1E series E-stops comply with the IEC "E-Stop Addendum to the Low Voltage Directive," this includes "tamper proof" operation whereby a change of contact state is not possible by "teasing" or "floating" the operator. 726 Contact Push Center Pull NC (BST-001) O O X NC-LB (BST-001S) O X X NO (BST-010) X O O NO-EM (BST-010S) X X O j Button Color Codes Color Code Black B Green G Red R Blue S Yellow Y k LED/Lens Color Codes Color Code Amber A Green G Red R Blue S White W l Full Voltage Codes Transformer Terminal Blocks AVD310N-R* AVD301N-R* AVD311N-R* AVD320N-R* AVD302N-R* 1NO-1NC 2NO 2NC o 40mm Push-Pull Circuit Breakers 1NO 1NC 1NO-1NC 2NO 2NC Part Number Contacts Part Number 1NO-1NC 2NC HN1E-BV4F11-R* HN1E-BV4F02-R* 1NO-1NC 2NC HN1E-LV4F11Qn-R-l HN1E-LV4F02Qn-R-l 8. 3 position push-pull available in spring return to center only. 9. *Available in red only. 10. **Not available in blue. 11. The most common configuration for motor starting applications. 12. For sub-assembly part numbers, see next page. 13. For nameplates and accessories, see page 744 and page 742. 14. For dimensions, see page 747. www.IDEC.com Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V 240V AC 240V (LED only) m Transformer Voltage Codes Voltage Code 120VAC 126 240VAC 246 480VAC 486 Transformers step down to 6V. n Lamp Type Codes Lamp Code Incandescent Blank LED D 1705151134 Switches & Pilot Devices o30mm - TWTD Series Switches & Pilot Devices Stop Switches (Sub-Assembled) Transformer* + Operator + Lamp + Button/Lens = Complete Part * Not required for full voltage units (full voltage clips used instead). Operators Lamps Part Number o40mm Pushlock Turn Reset AVD-300 AVLD3-0600N AYD-3100 o40mm Push-Pull AYLD-0600 3 pos AYLD22TK962-0B01 Incandescent Part Number Color Code LSTD-6k Black B 12V AC/DC LSTD-1k Green G 24V AC/DC LSTD-2k Red R 120V AC LSTD-H2k Blue S 240V AC LSTD-M4k Yellow Y 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 120V AC L-120L 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. Part Number Button for Pushlock Turn Reset Stop Switches (o40mm, red only) AVN3B-R Color Code Amber A Green G Red R Blue S White W Contact Blocks Part Number Style Buttons and Lenses Style k LED Color Codes Timers 2 pos Illuminated o 40mm Push-Pull LED Voltage 6V AC/DC Relays & Sockets Illuminated o40mm Pushlock Turn Reset Style Signaling Lights Style j Button Color Codes All Control Units Dummy Block 1NO 1NC BST-010 BST-001 BST-010S (early make) BST-001S (late break) BST-D Contactors 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining BST-010S and BST-001S result in overlapping contacts. Lens for Illuminated Pushlock Turn Reset Stop Switches (o40mm, red only) AVLN3LU-R Full Voltage Clips Primary Voltage (50/60Hz) AYD3BN-j Full Voltage Clips (2 required for each unit) APD-F Terminal Blocks Button for Push-Pull Stop Switches (o40mm) Part Number Transformers Lens for Illuminated Push-Pull Stop Switches (o40mm) 2 pos* AYLD3L-k 3 pos AYLD2L-k 1705151134 Primary Voltage (50/60Hz) Part Number 120V AC TWD-0126 240V AC TWD-0246 480V AC TWD-0486 Circuit Breakers 1. In place of j, specify the Button Color Code. (See table below) 2. In place of k, specify the LED Color Code. 3. *Not available in blue. Style 6V secondary voltage (uses 6V lamp). 800-262-IDEC (4332) * USA & Canada 727 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWTD Series Signaling Lights Pilot Lights (Assembled) Assembled Pilot Lights Relays & Sockets A Function P: P D 1 126 D N - R- ( ) Lamp Voltage Pilot Light (full voltage illuminated units only) 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120V AC (LED only) 240V: 240V AC (LED only) Series Designation D: TWTD Series Lens Shape 1: Dome Lens Color Code A: G: R: S: W: Y: Timers Rated Operational Voltage (Primary) Transformer Type 126: 120V AC 246: 240V AC 486: 480V AC Full Voltage Type 99: Full Voltage Amber Green Red Blue White Yellow Contactors Lamp Type Blank: Incandescent D: LED Use only when interpreting part numbers. Do not use for developing part numbers. LED and Incandescent Pilot Lights Style Operating Voltage k Lens Color Codes Part Number LED Incandescent Terminal Blocks Transformer Dome 120V AC 240V AC 480V AC APD1126DN-k APD1246DN-k APD1486DN-k APD1126N-k APD1246N-k APD1486N-k -- Circuit Breakers Code Amber A Green G Red R Blue S White W Yellow Y l Full Voltage Codes Full Voltage Dome APD199DN-k-l 1. In place of k, specify the Lens/LED Color Code. 2. In place of l, specify the Full Voltage Code (lamp voltage). 3. Yellow pilot light comes with white LED. 728 Color APD199N-k-l Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V 240V AC 240V (LED only) www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - TWTD Series Switches & Pilot Devices Pilot Lights (Sub-Assembled) Transformer* + Operator + Lamp + Lens = Complete Part * Not required for full voltage units (full voltage clips used instead). plus Operators Signaling Lights One Each from Left Column One Selection from Right Column Full Voltage Clips Style Part Number Part Number APD-F APD-006 Relays & Sockets Transformer Primary Voltage (50/60Hz) Required for all full voltage models. Two pieces each. Full Voltage Transformers APD-199 Style Primary Voltage (50/60Hz) Full voltage operator comes with full voltage clips. Style Part Number 120V AC TWD-0126 240V AC TWD-0246 480V AC TWD-0486 Timers LED Lenses Part Number 6V secondary voltage (use 6V lamp). Dome Lens APN106LN-k k LED/Lens Color Codes Lamps Style Incandescent Part Number 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k LSTD-M4k IS-6 12V AC/DC IS-12 24V AC/DC IS-24 120V AC L-120L A Green G Red R Blue S White W Yellow Y Yellow lens only. Yellow LED not available, use white LED. Circuit Breakers 240V AC 6V AC/DC Amber 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. 1705151134 800-262-IDEC (4332) * USA & Canada Terminal Blocks LED Voltage Code Contactors 1. In place of k, specify the Lens Color Code. 2. LED and incandescent lenses differ in shade only. Some colors have only one shade. Color 729 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWTD Series Relays & Sockets Signaling Lights Illuminated Pushbuttons (Assembled) Assembled Illuminated Pushbuttons A L ( ) D 2 126 11 (D) Lamp Voltage Function (full voltage only) Timers L: Momentary Action OL: Maintained Action 6V: 12V: 24V: 120V: 240V: Bezel Shape Blank: Octagonal F: Full Shroud 2: Extended 3: Mushroom o 40mm A: Amber G: Green R: Red S: Blue W: White Y: Yellow Rated Operational Voltage (Primary) Lamp Type Transformer Type 126: 120V AC 246: 240V AC 486: 480V AC Blank: Incandescent D: LED D: TWTD Series Contactors 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC (LED only) Lens Color Code Series Designation Terminal Blocks N - R - ( ) Lens Shape Full Voltage Type 99: Full Voltage Contact Arrangement 20: 2NO 02: 2NC 11: 1NO-1NC Circuit Breakers 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers step down to 6V. 730 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - TWTD Series Switches & Pilot Devices Illuminated Pushbuttons (Assembled) Illuminated Pushbuttons k Lens Color Codes Style Contacts Extended Lens Full Voltage Extended Lens with Full Shroud Transformer Full Voltage ALD2 m 11nN-k ALD2 m 20nN-k ALD2 m 02nN-k AOLD29911nN-k-l AOLD29920nN-k-l AOLD29902nN-k-l AOLD2 m 11nN-k AOLD2 m 20nN-k AOLD2 m 02nN-k 1NO-1NC 2NO 2NC ALFD29911nN-k-l ALFD29920nN-k-l ALFD29902nN-k-l AOLFD29911nN-k-l AOLFD29920nN-k l AOLFD29902nN-k-l 1NO-1NC 2NO 2NC ALFD2 m 11nN-k ALFD2 m 20nN-k ALFD2 m 02nN-k AOLFD2 m 11nN-k AOLFD2 m 20nN-k AOLFD2 m 02nN-k 1NO-1NC 2NO 2NC ALD39911nN-k-l ALD39920nN-k-l ALD39902nN-k-l AOLD39911nN-k-l AOLD39920nN-k-l AOLD39902nN-k-l Amber A Green G Red R Blue S White W Yellow Y l Full Voltage Codes Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V 240V AC 240V (LED only) m Transformer Voltage Codes Voltage Code 120VAC 126 240VAC 246 480VAC 486 6V secondary voltage (uses 6V lamp). Timers o 40mm Mushroom Lens ALD29911nN-k-l ALD29920nN-k-l ALD29902nN-k-l Maintained Code Relays & Sockets Full Voltage 1NO-1NC 2NO 2NC Momentary Color Signaling Lights Transformer 1NO-1NC 2NO 2NC Part Number n Lamp Type Codes Transformer ALD3 m 11nN-k ALD3 m 20nN-k ALD3 m 02nN-k AOLD3 m 11nN-k AOLD3 m 20nN-k AOLD3 m 02nN-k Lamp Code Incandescent Blank LED D Contactors 1. 2. 3. 4. 5. 6. 1NO-1NC 2NO 2NC In place of k, specify the Lens Color Code. In place of l, specify the Full Voltage Code (lamp voltage). In place of m, specify the Transformer Voltage Code. In place of n, specify the Lamp Type Code. Light is independent of switch position. Yellow pushbutton comes with white LED only. Terminal Blocks Circuit Breakers 1705151134 800-262-IDEC (4332) * USA & Canada 731 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWTD Series Illuminated Pushbuttons (Sub-Assembled) Transformer* + Contact Block + Operator + Lamp + Lens = Complete Part Signaling Lights *Not required for full voltage types (full voltage types use APD-F full voltage clips). Operators Lamps Style Part Number Style Momentary k LED/Lens Color Codes Maintained LED Relays & Sockets Extended ALD-0600 AOLD-0600 Incandescent Extended with Full Shroud ALFD-0600 AOLFD-0600 Voltage Part Number Color Code 6V AC/DC LSTD-6k Amber A 12V AC/DC LSTD-1k Green G 24V AC/DC LSTD-2k Red R 120V AC LSTD-H2k Blue S 240V AC LSTD-M4k White W 6V AC/DC IS-6 Yellow Y 12V AC/DC IS-12 24V AC/DC IS-24 120V AC L-120L Yellow lens only. Yellow LED not available, use white LED. 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. Timers Contact Blocks 40mm Mushroom ALD-0600 AOLD-0600 Lenses All Control Units Contactors Style Part Number Style Part Number 1NO 1NC BST-010 BST-001 BST-010S (early make) BST-001S (late break) Dummy Block Extended ALN06LU-k BST-D 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining BST-010S and BST-001S result in overlapping contacts (remain on, or closed, when switch is moved between two positions). Transformers Terminal Blocks o 40mm Mushroom Transformers In place of k, specify the Lens Color Code. Full Voltage Clips Style Circuit Breakers Style ALN3LU-k Full Voltage Clips (2 required for each unit) Part Number Primary Voltage (50/60Hz) Part Number 120V AC TWD-0126 240V AC TWD-0246 480V AC TWD-0486 6V secondary voltage (use 6V lamp). APD-F Required for all full voltage models. 732 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - TWTD Series Switches & Pilot Devices Non-Illuminated Selector Switches (Assembled) Signaling Lights Relays & Sockets Assembled Selector Switches A S D 2 ( ) ( ) 11 N - ( ) Function Circuit Number S: Selector Switch (See Circuit # column of Selector Switch Contact Arrangement Chart on beginning on page 739.) Series Designation D: TWTD Series 01: 1NC 02: 2NC 04: 4NC 22: 2NO-2NC Spring Return Action Operator Style Code Blank: Maintained 1: Spring return from Right 2: Spring return from Left 3: 2-Way spring return from Left and Right Blank: Knob Operator L: Lever Operator K: Key Operator Contactors 2: 2-Position 3: 3-Position 10: 1NO 20: 2NO 40: 4NO 11: 1NO-1NC Number of Positions Timers Contact Arrangement Code Terminal Blocks 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Custom key removal codes available. Please contact IDEC for details. Circuit Breakers 1705151134 800-262-IDEC (4332) * USA & Canada 733 Switches & Pilot Devices Non-Illuminated Selector Switches (Assembled) Non-Illuminated 2-Position Selector Switches Style Mounting L 1NO 1 2 O O X O 1NC 1 2 X O O O 1NO 1NC 1 2 O X X O 2NO 1 2 O O X X 2NC 1 2 X X O O 1 2 3 4 1 2 3 4 O X O X O O X X X O X O X X O O 2NO 2NC R Spring Return from Right Maintained L L R Spring Return from Left L R R Knob Lever Key Knob Lever Key Knob Lever Key Knob Lever Key Knob Lever Key ASD210N ASD2L10N ASD2K10N ASD201N-116 ASD2L01N-116 ASD2K01N-116 ASD211N ASD2L11N ASD2K11N ASD220N ASD2L20N ASD2K20N ASD202N-104 ASD2L02N-104 ASD2K02N-104 ASD2110N ASD21L10N ASD21K10N ASD2101N-116 ASD21L01N-116 ASD21K01N-116 ASD2111N ASD21L11N ASD21K11N ASD2120N ASD21L20N ASD21K20N ASD2102N-104 ASD21L02N-104 ASD21K02N-104 ASD2210N ASD22L10N ASD22K10N ASD2201N-116 ASD22L01N-116 ASD22K01N-116 ASD2211N ASD22L11N ASD22K11N ASD2220N ASD22L20N ASD22K20N ASD2202N-104 ASD22L02N-104 ASD22K02N-104 Knob Lever Key ASD222N ASD2L22N ASD2K22N ASD2122N ASD21L22N ASD21K22N ASD2222N ASD22L22N ASD22K22N Knob Lever Key ASD222N-111 ASD2L22N-111 ASD2K22N-111 ASD2122N-111 ASD21L22N-111 ASD21K22N-111 ASD2222N-111 ASD22L22N-111 ASD22K22N-111 1. The truth table indicates the operating position of contact block when the operator is switched to that position. X = On (closed contacts) O = Off (open contacts) X X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these two positions. 2. All knob and lever selector switches come in black. Other colors are available by ordering the knob or lever separately. 3. Custom contact arrangements available, see page 739. Non-Illuminated 3-Position Selector Switches Style Part Number Maintained Spring Return from Right Spring Return from Left L C C C C Spring Return Two-Way Mounting Operator Position Contact Terminal Blocks Contactors Timers 2NO 2NC 2NO 1 2 X O O O O X Knob Lever Key ASD320N ASD3L20N ASD3K20N ASD3120N ASD31L20N ASD31K20N ASD3220N ASD32L20N ASD32K20N ASD3320N ASD33L20N ASD33K20N 2NC 1 2 O X X X X O Knob Lever Key ASD302N ASD3L02N ASD3K02N ASD3102N ASD31L02N ASD31K02N ASD3202N ASD32L02N ASD32K02N ASD3302N ASD33L02N ASD33K02N 2NO 2NC 1 2 3 4 X O O X O O X X O X X O Knob Lever Key ASD322N ASD3L22N ASD3K22N ASD3122N ASD31L22N ASD31K22N ASD3222N ASD32L22N ASD32K22N ASD3322N ASD33L22N ASD33K22N 1 2 3 4 1 2 3 4 1 2 3 4 X X O O O O O O X O X O X O O X O X O X O X O X Knob Lever Key ASD322N-309 ASD3L22N-309 ASD3K22N-309 ASD3122N-309 ASD31L22N-309 ASD31K22N-309 ASD3222N-309 ASD32L22N-309 ASD32K22N-309 ASD3322N-309 ASD33L22N-309 ASD33K22N-309 Knob Lever Key ASD322N-310 ASD3L22N-310 ASD3K22N-310 ASD3122N-310 ASD31L22N-310 ASD31K22N-310 ASD3222N-310 ASD32L22N-310 ASD32K22N-310 ASD3322N-310 ASD33L22N-310 ASD33K22N-310 Knob Lever Key ASD340N ASD3L40N ASD3K40N ASD3140N ASD31L40N ASD31K40N ASD3240N ASD32L40N ASD32K40N ASD3340N ASD33L40N ASD33K40N 1 2 3 4 O X O X O X X O X O X O O O O O X X X X Knob Lever Key ASD304N ASD3L04N ASD3K04N ASD3104N ASD31L04N ASD31K04N ASD3204N ASD32L04N ASD32K04N ASD3304N ASD33L04N ASD33K04N 2NO 2NC 2NO 2NC 4NO Circuit Breakers Part Number Operator Position Contact Relays & Sockets Signaling Lights Switches & Pilot Devices o30mm - TWTD Series 4NC 734 R X O X O L R L www.IDEC.com R L R L C R 1705151134 Switches & Pilot Devices o30mm - TWTD Series Switches & Pilot Devices Non-Illuminated Selector Switches (Sub-Assembled) Contact Blocks + Operator + Knob or Lever* + Color Insert* = Complete Part Operators Style Signaling Lights 1. *Not needed with key type switches. 2. Knob type shown. Handles and Inserts Position Description 2 3 Key 3 Spring return from right ASD2100 Spring return from left ASD2200 Maintained, Cam 1 Maintained, Cam 2 ASD300-1 ASD300-2 Spring return from right, Cam 1 Spring return from right, Cam 2 ASD3100-1 ASD3100-2 Spring return from left, Cam 1 Spring return from left, Cam 2 ASD3200-1 ASD3200-2 Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 ASD3300-1 ASD3300-2 Maintained ASD2K00-RA Spring return from right ASD21K00-RL Spring return from left ASD22K00 Maintained, Cam 1 Maintained, Cam 2 ASD3K00-1 ASD3K00-2 ASD31K00-1-RLC ASD31K00-2-RLC Spring return from left, Cam 1 Spring return from left, Cam 2 ASD32K00-1-RRC ASD32K00-2-RRC Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 ASD33K00-1-RC ASD33K00-2-RC 1. Order knobs, levers, color inserts separately (see below). 2. For key switches, keys are removable in all maintained positions. Other options available, contact IDEC for details. 3. See page 741 "Operator Truth Tables" for details of difference between cams. j Color Codes Code Black B Blue S Green G Red R Yellow Y White W Knob ASDHHY-j Lever ASDHHL-j* Color Insert TW-HC1-j 1. In place of j, specify the Color Code. *Not available in yellow. Contact Blocks Style All Control Units Dummy Block Part Number 1NO 1NC BST-010 BST-001 BST-010S (early make) BST-001S (late break) BST-D 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining BST-010S and BST-001S result in overlapping contacts (remain on, or closed, when switch is moved between two positions). Terminal Blocks Knob/Lever Color Part Number Contactors Spring return from right, Cam 1 Spring return from right, Cam 2 Style Timers 2 ASD200 Relays & Sockets Knob/Lever Part Number Maintained 1705151134 Circuit Breakers 1. Knob/Lever not available in white. 2. Color inserts not available in Black. 3. Lever not available in yellow. 800-262-IDEC (4332) * USA & Canada 735 Switches & Pilot Devices o30mm - TWTD Series Signaling Lights Switches & Pilot Devices Illuminated Selector Switches (Assembled) Assembled Illuminated Selector Switches Relays & Sockets A SL D 2 (2) 99 11 D N - 111 - R - 24 Function Lamp Voltage (Full Voltage Units Only) SL:Illuminated Selector Switch 6V: 12V: 24V: 120V: 240V: Series Designation D: TWTD series Number of Positions Lens Color Code Timers 2: 2-Position 3: 3-Position A: Amber G: Green R: Red S: Blue W: White Y: Yellow Spring Return Action Blank: Maintained 1: Spring return from Right 2: Spring return from Left 3: Two-Way spring return from Left and Right Circuit Code Number Contactors Rated Operational Voltage (Primary) Transformer Type 126: 120V AC 246: 240V AC 486: 480V AC See Circuit # column of Selector Switch Contact Arrangement Charts on page 739. Full Voltage Type 99: Full Voltage Lamp Type Blank: Incandescent Lamp D: LED Lamp Contact Arrangement Code Terminal Blocks 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC (LED only) 20: 2NO 02: 2NC 40: 4NO 04: 4NC 11: 1NO-1NC 22: 2NO-2NC Circuit Breakers Use only when interpreting part numbers. Do not use for developing part numbers. 736 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - TWTD Series Switches & Pilot Devices Illuminated Selector Switches (Assembled) Illuminated 2-Position Selector Switches k LED/Lens Color Codes Mounting 1 2 1 2 1 2 1 2 3 4 1 2 3 4 2NO 2NC 2NO 2NC 2NO 2NC L R O X O O X X O X O X O O X X X O X X O O X O X O X X O O Maintained Lamp Circuit Type L Spring Return from Left Spring Return from Right L R L R R Transformer Full Voltage Transformer Full Voltage Transformer Full Voltage ASLD2 m11nN-k ASLD29911nN-k-l ASLD2 m20nN-k ASLD29920nN-k-l ASLD2 m02nN-104-k ASLD29902nN-104-k-l ASLD21 m11nN-k ASLD219911nN-k-l ASLD21 m20nN-k ASLD219920nN-k-l ASLD21 m02nN-104-k ASLD219902nN-104-k-l ASLD22 m11nN-k ASLD229911nN-k-l ASLD22 m20nN-k ASLD229920nN-k-l ASLD22 m02nN-104-k ASLD229902nN-104-k-l Transformer Full Voltage ASLD2 m22nN-k ASLD29922nN-k- l ASLD21 m22nN-k ASLD219922nN-k-l ASLD22 m22nN-k ASLD229922nN-k-l Transformer Full Voltage ASLD2 m22nN-111-k ASLD29922nN-111-k-l ASLD21 m22nN-111-k ASLD219922nN-111-k-l Color Code Amber A Green G Red R Blue S White W Yellow Y l Full Voltage Codes Voltage ASLD22 m22nN-111-k ASLD229922nN-111-k-l Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V 240V AC 240V (LED only) Relays & Sockets 1NO 1NC Part Number Operator Position Signaling Lights Contact Style Illuminated 3-Position Selector Switches, Maintained and Spring Return 2NC 2NO 2NC 2NO 2NC 4NC C X O O X O O X X O O X X O X X O X O X O O O O O X X X X X O O X X X O O O O O O X O X O O X O X R O X X O O X X O X O O X O X O X O X O X X O X O Lamp Circuit Type L C R L C Spring Return from Left L R C Spring Return Two-Way L R C R Transformer Full Voltage Transformer Full Voltage ASLD3 m 20nN-k ASLD39920nN-k-l ASLD3 m 02nN-k ASLD39902nN-k-l ASLD31 m 20nN-k ASLD319920nN-k- l ASLD31 m 02nN-k ASLD319902nN-k-l ASLD32 m 20nN-k ASLD329920nN-k-l ASLD32 m 02nN-k ASLD329902nN-k-l ASLD33 m 20nN-k ASLD339920nN-k-l ASLD33 m 02nN-k ASLD339902nN-k-l Transformer Full Voltage ASLD3 m 22nN-k ASLD39922nN-k-l ASLD31 m 22nN-k ASLD319922nN-k-l ASLD32 m 22nN-k ASLD329922nN-k-l ASLD33 m 22nN-k ASLD339922nN-k-l Transformer Full Voltage ASLD3 m 22nN-309-k ASLD39922nN-309-k-l ASLD31 m 22nN-309-k ASLD319922nN-309-k-l ASLD32 m 22nN-309-k ASLD329922nN-309-k-l ASLD33 m 22nN-309-k ASLD339922nN-309-k-l Transformer Full Voltage ASLD3 m 22nN-310-k ASLD39922nN-310-k-l ASLD31 m 22nN-310-k ASLD319922nN-310-k-l ASLD32 m 22nN-310-k ASLD329922nN-310-k-l ASLD33 m 22nN-310-k ASLD339922nN-310-k-l Transformer Full Voltage ASLD3 m 40nN-k ASLD39940nN-k-l ASLD31 m 40nN-k ASLD319940nN-k-l ASLD32 m 40nN-k ASLD329940nN-k-l ASLD33 m 40nN-k ASLD339940nN-k-l Transformer Full Voltage ASLD3 m 04nN-k ASLD39904nN-k-l ASLD31 m 04nN-k ASLD319904nN-k-l ASLD32 m 04nN-k ASLD329904nN-k-l ASLD33 m 04nN-k ASLD339904nN-k-l m Transformer Voltage Codes n Lamp Type Codes Voltage Code Lamp Code 120VAC 240VAC 480VAC 126 246 486 Incandescent Blank LED D Transformers step down to 6V (use 6V lamp). 800-262-IDEC (4332) * USA & Canada Circuit Breakers 1. In place of k, specify the Lens/LED Color Code, in place of l, specify the Full Voltage (lamp voltage) Code, in place of m, specify the Transformer Voltage Code and in place of n specify the Lamp Type Code. 2. The truth table indicates the operating position of contact block when the operator is switched to that position. X = On (Closed Contacts) O = Off (Open Contacts) X X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these positions 3. Yellow selector switch comes with white LED. 1705151134 Spring Return From Right Terminal Blocks 4NO L Maintained Contactors 2NO 2NC 1 2 1 2 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Part Number Operator Position Timers 2NO Mounting Contact Style Light is independent of switch position. 737 Switches & Pilot Devices Illuminated Selector Switches (Sub-Assembled) Transformer* + Contact Block + Operator + Lamp + Lens Operators Style Description Part Number 2 Maintained ASLD200 3 Maintained, Cam 1 Maintained, Cam 2 ASLD300-1 ASLD300-2 Spring return from right ASLD2100 Spring return from left ASLD2200 Spring return from right, Cam 1 Spring return from right, Cam 2 ASLD3100-1 ASLD3100-2 Spring return from left, Cam 1 Spring return from left, Cam 2 ASLD3200-1 ASLD3200-2 Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 ASLD3300-1 ASLD3300-2 Operator 2 Timers Part Number Style All Control Units 1NO 1NC BST-010 BST-001 BST-010S (early make) BST-001S (late break) Dummy Block BST-D 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining BST-010S and BST-001S result in overlapping contacts (remain on, or closed, when switch is moved between two positions). Full Voltage Clips Style Lenses Style Part Number Knob Contactors Complete Part Contact Blocks Position 3 ASLNHU-j Part Number Full Voltage Clips (2 required for each unit) APD-F Required for all full voltage models. Transformers Lamps Style LED Terminal Blocks = *Not required for full voltage units (use APD-F full voltage clips instead). Relays & Sockets Signaling Lights Switches & Pilot Devices o30mm - TWTD Series Incandescent Voltage Part Number 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 120V AC L-120L Circuit Breakers 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. Style Primary Voltage (50/60Hz) Part Number 120V AC TWD-0126 240V AC TWD-0246 480V AC TWD-0486 Transformers 6V secondary voltage. k LED/Lens Color Codes Color Code Color Code Amber A Blue S Green G White W Red R Yellow Y Yellow lens only. Yellow LED not available, use white LED. 738 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - TWTD Series Switches & Pilot Devices Contact Arrangement Charts How to Read Contact Arrangement Charts To determine contact block mounting position, first make sure the selector switch is oriented as shown on the right Operator Position Contact Arrangement Type and quantity of switch contacts Contact Block Mounting Position Circuit Number Position or mounting contact blocks on operator Contact Block Part Number X = On (Closed Contacts) O = Off (Open Contacts) X X = Overlapping Contacts: Remain on (closed) when switch is moved between these two positions Part number to use when ordering sub-assembly contact blocks, as required for use with corresponding mounting position Contact Arrangement Chart: 2-Position Selector Switches Style Circuit Number 1NO N/D 1NC 116 1NO 1NC 103 600 601 N/D 2NC 104 N/D 2NO 2NC 110 4NO 1705151134 N/D 1 O X BST-010 2 O O BST-D 1 X O BST-001 2 O O BST-D 1 O X BST-010 2 X O BST-001 1 X O BST-001 2 O X BST-010 1 O X BST-010S 2 X O BST-001S 1 X O BST-001S 2 O X BST-010S 1 O X BST-010 2 O X BST-010 1 X O BST-001 2 X O BST-001 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 O X O X X O X O O O X X O O O O X O X O O X O X X X O O X X X X BST-010 BST-001 BST-010 BST-001 BST-001 BST-010 BST-001 BST-010 BST-010 BST-010 BST-001 BST-001 BST-010 BST-010 BST-010 BST-010 L R L R Spring Return from Left L Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 800-262-IDEC (4332) * USA & Canada R Circuit Breakers 111 R Spring Return from Right Terminal Blocks 2NO L Maintained Description Contactors 1NO-EM 1NC-LB Contact Block Part Number Timers N/D Operator Part Number Relays & Sockets Contact Mounting Position Operator Position Signaling Lights * N/D = No designation Truth table indicates the operating position of contact block when operator is switched to that position. 739 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWTD Series Contact Arrangement Chart: 3-Position Selector Switches Style Operator Part Number Operator Position Contact Circuit Number Signaling Lights 202 203 1NO 1NC Relays & Sockets 302 303 N/D 2NO 301 Timers 304 2NC N/D Contactors N/D 210 2NO 2NC Terminal Blocks 308 309 Circuit Breakers 310 Mounting Position Contact Block Part Number L C 1 X O O BST-010 2 X X O BST-001 1 O X X BST-001 2 O O X BST-010 1 X O X BST-010 2 X X O BST-001 1 O X O BST-001 2 O O X BST-010 1 X O O BST-010 2 O O X BST-010 1 X O X BST-010 2 O O X BST-010 1 O X O BST-001 2 X X O BST-001 1 O X X BST-001 2 X X O BST-001 1 X O O BST-010 2 O O X BST-010 3 O X X BST-001 4 X X O BST-001 1 O X X BST-001 2 O O X BST-010 3 O X X BST-001 4 O O X BST-010 1 X O X BST-010 2 X X O BST-001 3 X O X BST-010 4 X X O BST-001 1 X O X BST-010 2 X X O BST-001 3 O X O BST-001 4 O O X BST-010 1 O X O BST-001 2 O O X BST-010 3 O X O BST-001 4 O O X BST-010 R Description Maintained L C R Spring Return from Right L C R Spring Return from Left L C R Two-Way L C R Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 1. Each operator sub-assembly is available as a "-1" and a "-2" for 3-position selector switches. The internal cam of a "-1" is different from that of a "-2". This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X X Overlapping contacts remain on (closed) when switch is moved between these two positions. 740 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - TWTD Series Switches & Pilot Devices Contact Arrangement Chart: 3-Position Selector Switches Style Operator Part Number Operator Position Contact Circuit Number Mounting Position 4NO 305 4NC 314 C 1 X O O BST-010 2 O O X BST-010 3 X O O BST-010 4 O O X BST-010 1 X O X BST-010 2 O O X BST-010 3 X O X BST-010 4 O O X BST-010 1 O X X BST-001 2 X X O BST-001 3 O X X BST-001 4 X X O BST-001 1 O X O BST-001 2 X X O BST-001 3 O X O BST-001 4 X X O BST-001 R L C R L C Spring Return from Left L R C R Two-Way L C R Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Relays & Sockets N/D L Description Maintained Signaling Lights N/D Contact Block Part Number Spring Return from Right Operator Truth Tables Use the following tables to build custom selector switches. 2 Position Selector Switches Contact 3 Position Selector Switches Mounting Position BST-001 (NC) ASD200 BST-010S (NO-EM) BST-001S (NC-LB) Operator Position Left Right L O X R O X L X O R X O L O X R O X L X O R X O Contact BST-010 (NO) ASD300-1 ASLD300-1 ASD3K00-1 BST-001 (NC) BST-010S (NO-EM) BST-001S (NC-LB) Mounting Position Operator Position Left Center Right L X O O R O O X L O X X R X X O X O O O O X L O X X R X X O Mounting Position Left Center Right L X O X R O O X L O X O R X X O L X O X R O O X L O X O R X X O Terminal Blocks L R Contactors BST-010 (NO) 3 Position Push/Pull Switches Contact AYLD22 Operator Position Contact Normal Push BST-010 (NO) O O X BST-001 (NC) X O O BST-010S (NO-EM) O X X BST-001S (NC-LB) X X O BST-010 (NO) ASD300-2 ASLD300-2 ASD3K00-2 BST-001 (NC) BST-010S (NO-EM) 800-262-IDEC (4332) * USA & Canada Operator Position Circuit Breakers Pull BST-001S (NC-LB) 1705151134 Timers 1. Each operator sub-assembly is available as a "-1" and a "-2" for 3-position selector switches. The internal cam of a "-1" is different from that of a "-2". This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X X Overlapping contacts remain on (closed) when switch is moved between these two positions. 741 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWTD Series Accessories -- TWTD Series TWTD Series Accessories Item Relays & Sockets Signaling Lights Lamp Removal Tool Metal Bezel Plastic Bezel Timers Boot/Cover Contactors Terminal Blocks Description/Usage Rubber tool used to install or remove LED's and incandescent lamps Replacement locking ring/ bezel OR-55 Standard octagonal units (chrome-pl.). OG-81 Extended, non-illuminated (chrome-pl.). OG-82 Extended, illuminated (chrome-pl.). OG-83L Jumbo Mushroom Shallow Shroud ABN4G Jumbo Mushroom Deep Shroud ABN4F Black plastic locking ring/bezel Used to cover and protect pushbuttons Part Number OGP11B In place of j, specify Neoprene Rubber Boot color: B (black), G (green), R (red), Y (yellow) OC-11 j Flush units (clear plastic -40 to +60C). OC-121 Extended units (clear plastic -40 to +60C). OC-122 Plastic washer For nameplates or panels that should not be scratched. OGL-D1T Thrust washer/Anti-rotation ring for use with notched panel cutout. OGL-D1S Anti-Rotation Ring Mounting Hole Plug Circuit Breakers Appearance Plugs used to fill unused 30mm panel cutouts. Plastic with locking nut attached. OBP-11 Metal with locking nut attached OB-11 Grey rubber (-5 to +60C) OB-13 Terminal Tab Adaptor Tab #250 17/64" x 3/64" (6.35mm x 0.8mm): Single tab Full Voltage Adaptor Used on all full voltage illuminated units. Two required per unit. (M3.5 screw and saddle) APD-F Lock Out Adaptor Used to provide lockout protection for TWTD pushbuttons and knob selectors. o 1-13/64" (30mm) OL-KL1 Replacement Keys Pair of keys (#0) TW-SK 742 www.IDEC.com TW-FA1 1705151134 Switches & Pilot Devices o30mm - TWTD Series Switches & Pilot Devices Fingersafe Covers for TWTD Series Item Description Used with Part Number Fingersafe terminal cover, for full voltage pilot lights, adds 3mm to overall depth APD199... full voltage pilot lights Fingersafe terminal cover, for contact blocks, adds 3mm to overall depth Non-Illuminated pushbuttons ABD..., and AOD... N-VL2 Fingersafe terminal cover, adds 1.5mm to overall depth Transformer pilot lights and illuminated units N-VL3 Fingersafe terminal cover, adds 4 mm to depth Full voltage illuminated pushbuttons N-VL4 APD-PVL Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 1705151134 800-262-IDEC (4332) * USA & Canada 743 Switches & Pilot Devices Nameplates -- TWTD Series Faceplates NAKD O1.19" (30.5mm) O1.19" (30.5mm) 30.5mm 5mm Description Relays & Sockets 1.95" (50mm) (30.5mm) 2.24" (57.5mm) O1.19" HNAV 1.95" (50mm) 2.03" (52mm) 1.56" (40mm) Dimensions NAQD o60mm NALD 1.85" (47.5mm) Signaling Lights Switches & Pilot Devices o30mm - TWTD Series Part Number Nameplate (blank) NALD-B (black) NALD-R (red) NAKD-B (black) NAKD-R (red) NAQD-B (black) NAQD-R (red) HNAV-O Nameplate (engraved) NALD-j NAKD-j NAQD-j HNAV-27 "Emergency Stop" 1. Nameplates are made of 0.031" aluminum. Lettering is white letters engraved on black background. 2. In place of j, insert either the standard legend code from table below or custom engraving delimited by " ". 3. HNAV available in yellow only. Standard Legend Codes Pushbuttons Terminal Blocks Contactors Timers Legend AUTO CLOSE DOWN EMERG.STOP* FAST FORWARD HAND HIGH IN INCH JOG LOW LOWER OFF ON Code 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 Pushbuttons/Selector Switches Legend OPEN OUT RAISE RESET REVERSE RUN SLOW START STOP* STOP TEST UP I (Int'l On) O (Int'l Off) EMO Code 116 117 118 119 120 121 122 123 124 125 126 127 150 151 152 Legend AUTO-MAN CLOSE-OPEN DOWN-UP FAST-SLOW FOR-REV HAND-AUTO HIGH-LOW JOG-RUN LEFT-RIGHT LOWER-RAISE MAN-AUTO OFF-ON ON-OFF OPEN-CLOSE RAISE-LOWER Code 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 Legend REV-FOR RUN-JOG RUN-SAFE SAFE-RUN SLOW-FAST START-STOP STOP-START UP-DOWN Selector Switches Code 216 217 218 219 220 221 222 223 Legend AUTO-MAN-OFF AUTO-OFF-MAN CLOSE-OFF-OPEN DOWN-OFF-SLOW FAST-OFF-SLOW FOR-OFF-REV LEFT-OFF-RIGHT LOWER-OFF-RAISE OFF-MAN-AUTO OFF-SLOW-FAST OFF-1-2 OPEN-OFF-CLOSE SLOW-OFF-FAST SUMMER-OFF-WINTER UP-OFF-DOWN 1-OFF-2 HAND-OFF-AUTO Code 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 1. *Available in Red as standard legend code 104 and 124. To order engraved nameplate and codes, add legend code to nameplate part number. Character height based on the number of characters, space and size of nameplate. Standard character size is 3/16". 2. Nameplates with standard legends are the same list price as blank nameplates. Special engravings, additional cost. Circuit Breakers To specify engraving instructions, use the Nameplate order form on next page. 744 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - TWTD Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To ensure engraving accuracy, fax it to your IDEC representative. or Distributor. IDEC Rep/Distributor Contact:__________________________________ Your Company Name:__________________________________________ PO number (if known):__________________________________ Telephone:__________________________________________ IDEC Rep/Distributor Phone:__________________________________ Fax & Email:__________________________________________ IDEC Rep/Distributor Fax & Email:__________________________________ NALD Nameplate Step 1. Choose Letter Size - 7/64" or 1/8". Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8" size letters cannot exceed 13 characters. Engraving Location Sample Letter Sizes 7/64" 16 characters max (for 7/64" size letters) 1/8" 13 characters max (for 1/8" size letters) Letter Size 7/64" Letters: 1/8" Letters: Letter Size Relays & Sockets Step 2. Specify Quantity. Enter the number of nameplates desired in the box on the right. NAKD Nameplate Signaling Lights Your Name:__________________________________________ Switches & Pilot Devices Custom engraved Nameplates Order Form -- TWTD Series Qty 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Step 1. Choose Letter Size - 7/64" or 1/8". Timers Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8" size letters cannot exceed 9 characters. Engraving Location Step 2. Specify Quantity. 1 Sample Letter Sizes Qty Contactors Enter the number of nameplates desired in the box on the right. 1/8" Letters: NAQD Nameplate Step 1. Choose Letter Size - 7/64" or 1/8". 1 2 3 20 characters max (for 7/64" size letters) 1/8" 16 characters max (for 1/8" size letters) Letter Size 4 5 Step 2. 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Sample Letter Sizes Enter the number of nameplates desired in the box on the right. 3/32" Letters: Circuit Breakers Specify Quantity. 1705151134 Terminal Blocks Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8" size letters cannot exceed 16 characters. Engraving Location 7/64" Letter Size 1/8" Letters: Qty 800-262-IDEC (4332) * USA & Canada 745 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o30mm - TWTD Series Switch Engraving Order Form - TWTD Series Copy this order form and use it to specify Letter Height, Maximum Number of Lines and Text to be engraved. To insure engraving accuracy, fax it to your IDEC representative or Distributor. Your Company: Telephone: Name: Fax: Address: Email: PO: Part Number to be Engraved: Please check one of the boxes below to indicate your choice of engraving options: o29mm, o40mm Mushroom Head 65mm Jumbo Mushroom Relays & Sockets Square Switch Engraving Engraving Area 1 Area 2 # of Lines Letter Height Max. Characters Per Line 5/32 7 # of Lines 1 Letter Height Max. Characters Per Line 3/4 4 1 1/8 8 5/32 7 5/16 5/16 5 5 Timers 2 3 1/8 8 1/8 8 4 2 Custom* Contactors Round Switch 4 Letter Height Max. Characters Per Line 5/32 7 1/8 8 1 6 5/32 8 5/32 8 1/8 9 1/8 9 3 *Engraving is possible, but character size will be smaller than standard sizes. # of Lines 1/4 Terminal Blocks 3 4 Engraving Area 1 1 Engraving Area 2 1 Letter Height Max. Characters Per Line 5/32 5 1/8 5 5/32 7 1/8 7 1. Above mentioned specifications hold true for standard size pushbuttons (round and square). 2. Engraving Area 2 can be engraved for 40mm mushroom head non-Illuminated pushbutton only. 3. Engraving is done on the button itself for non-Illuminated push buttons and on marking plate for illuminated push buttons and pilot lights. 4. Please enter text exactly how you want it engraved, take care to emphasize capital or small letters. Enter text to be engraved: Sample Letter Sizes 1/8 Letters: Line 1: 5/32 7 1/8 8 Line 3: 1/8 8 Line 4: 2 # of Lines 5/32 Letters: Line 2: All engraving is 5/8mm wide. Custom* Circuit Breakers *Engraving is possible, but character size will be smaller than standard sizes. For IDEC Internal Use Only: Work Order #: 746 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - TWTD Series Switches & Pilot Devices Dimensions (mm) Pushbutton Panel Thickness 0.8 to 7.5 40 53 (1 or 2 blocks) 9 14.5 Mushroom Pushbutton w/Full Shroud Panel Thickness 0.8 to 7.5 o40 o40 23 5.5 Dimension B 0.351" (9mm) 0.566" (14.5mm) 0.663" (17mm) o 0.975" (25mm) o 0.975"(25mm) o 1.11" (28.5mm) Mushroom Mushroom w/Full Shroud Jumbo Mushroom o 1.56" (40mm) 0.858" (22mm) 0.936" (24mm) 1.13" (29mm) o 1.56" (40mm) o 1.87" (48mm) o 2.54" (65mm) Mushroom, Pushlock Turn Reset and Push-Pull o 1.56" (40mm) *0.975" (25mm) **0.975" (25mm) o 1.56" (40mm) o 1.56" (40mm) *Dimension when operator is in reset position. **Dimension when operator is in pull position. 40 53 (1 or 2 blocks) 76 (3 or 4 blocks) Signaling Lights 76 (3 or 4 blocks) M3.5 Terminal Screw Dimension A Flush Extended Extended w/Full Shroud o40 o25 23 5.5 Pushbuttons o35 M3.5 Terminal Screw 22 Relays & Sockets Illuminated Pushbuttons M3.5 Terminal Screw Full Voltage Panel Thickness 0.8 to 7.5 M3.5 Terminal Screw M3 Terminal Screw o24 5.5 40 o40 23 40 9 9 A 24 63 (2 blocks) 86 (4 blocks) Flush w/Full Shroud 0.975" (25mm) 0.995" (25.5mm) o 0.936" (24mm) o 0.936" (24mm) Extended w/Full Shroud 0.741" (19mm) 0.761" (19.5mm) o 0.936" (24mm) o 0.936" (24mm) o 1.56" (40mm) Mushroom Pushlock Turn Reset, Push-Pull *0.975" (25mm) **0.975" (25mm) o 1.56" (40mm) o 1.56" (40mm) Pilot Lights M3.5 Terminal Screw M3.5 Terminal Screw Panel Thickness: 0.8 to 7.5 mm A:29.5 9 40 22 Contactors B:64.5 o40 Dimension B Timers Dimension A o25 97.5 (2 blocks) 120.5 (4 blocks) o35 o40 o35 B Illuminated Pushbuttons Panel Thickness 0.8 to 7.5 M3 Terminal Screw o35 w/Transformer *Dimension when operator is in reset position. **Dimension when operator is in pull position. Selector Switches 90 45 5.5 40 23 53 (1 or 2 blocks) 21 76 (4 blocks) 5.5 40 21.5 76 (4 blocks) 45 45 o40 o35 53 (1 or 2 blocks) 90 M3.5 Terminal Screw 45 45 23 9 53 (1 or 2 blocks) 16.5 Terminal Blocks 23 5.5 Panel Thickness 0.8 to 7.5 90 M3.5 Terminal Screw o40 45 o35 M3.5 Terminal Screw Key Panel Thickness 0.8 to 7.5 o40 Lever Panel Thickness 0.8 to 7.5 o35 Knob 40 38 76 (4 blocks) Illuminated Knob Panel Thickness 0.8 to 7.5 (including nameplate) 5.5 B: 97.5 (2 blocks), 120.5 (4 blocks) 1705151134 45 o40 40 23 63 (2 blocks) A: 86 (4 blocks) 90 45 Circuit Breakers o25 M3 Terminal Screw o35 M3.5 Terminal Screws 9 28 800-262-IDEC (4332) * USA & Canada 747 Switches & Pilot Devices Selector Switches Panel Cut-Out O 0.195" (5mm) 1. *Jumbo Mushroom < 2.61" (66mm) 2. Minimum mounting centers are applicable to switches with one stack of contact blocks. When mounting two stacks of contact blocks, minimum centers should allow for access to wiring. 3. The o 0.195" (o 5mm) recess is necessary when either the nameplate or anti-rotation ring is used. O 1.20" (30.5mm) 1.64" (42mm) > 1.95" (50mm)* IlluminatedSelector Switches OL-KL1 OC-31 Lock-Out Adaptor Pushbutton Clear Boot OGL-31 OB-31 Anti-Rotation Ring Mounting Hole Rubber Plug o29 70 30 93 10.2 6.5 0 o5 24 o3 0.2 Key Hole o8 29.5 3.5 o32.6 Panel Thickness 0.8 to 3.2 R6 Relays & Sockets 82.5 18 (OC-31) 22 (OC-32) o22 o27.4 o25 3.5 Signaling Lights Switches & Pilot Devices o30mm - TWTD Series 0.8 Waterproof Rubber Gasket 0.5t 30 N-VL2 N-VL3 N-VL4 Contactors Timers Finger-Safe Cover Circuit Breakers Terminal Blocks APD-PVL 748 www.IDEC.com 1705151134 Switches & Pilot Devices o30mm - TWTD Series Adjustment for Panel Thickness Each unit is shipped with several waterproof gaskets which are 0.06" (1.5mm) and 0.12" (3mm) thick. Combine the gaskets for a dimension approximately equal to panel thickness and install between the bezel and the body of the unit. Transformer units are recommended for use in areas subjected to inductive noise. When using full voltage types, install a protection diode as shown below. Use diode with DC power supply to protect against surges and noise. Signaling Lights Make sure that LED illuminated units are installed with correct polarity, as indicated at the terminals. Switches & Pilot Devices Operating Instructions Application Example For Push-To-Test Pilot Light A typical application of illuminated pushbuttons is a push-to-test pilot light which can be used to check the lamp/LED circuit. Transformer/AC-Adapter Circuit Relays & Sockets A trim washer must be used with a thrust washer or a nameplate to prevent the control unit from rotating in the mounting hole. When using anti-rotation rings (trim washer with thrust washer or nameplate), install as shown below. Selector Switches Full Voltage Circuit Timers The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW-HC1) into the Standard Operating Positions. Standard Operation Positions 2-Position, 90 3-Position, 45 1 1 0 2 2 Contactors Non-Illuminated 3-Position Operators 1 0 1 2 1 0 0 2 2 Installation of TWTD Series Units Terminal Blocks TWTD Pilot Lights TWTD Illuminated Pushbuttons TWTD Selector Switches (Transformer or Full Voltage) Circuit Breakers Terminal X1 = Positive Terminal X2 = Negative Installation of LED Illuminated Units 1705151134 800-262-IDEC (4332) * USA & Canada 749