Features * Low cost 1W converter * Power sharing on dual output versions * 1kVDC/1s or 2kVDC/1s isolation option * Optional continuous short circuit protection * Efficiency up to 85% * UL94V-0 package material Unregulated Converters Description The RB series DC/DC converter has been designed for isolating or converting DC power rails in general purpose applications. Although low cost, it does not compromise on features and offers 1KVDC/1s or 2kVDC/1s isolation, a -40C to +85C operating temperature range and optional continuous short circuit protection. DC/DC Converter RB 1 Watt SIP7 Single and Dual Output Selection Guide Part Number nom. Input Output Output Efficiency max. Capacitive Voltage VoltageCurrent typ. (1)Load (2) [VDC] [VDC][mA] [%] [F] RB-xx3.3S(3,4) 3.3, 5, 12, 15, 24 3.3 303 75 2200 3.3, 5, 12, 15, 24 5 200 70-78 2200 RB-xx09S (3,4) 3.3, 5, 12, 15, 24 9 111 70-78 1000 3.3, 5, 12, 15, 24 12 84 78-80 470 RB-xx15S (3,4) 3.3, 5, 12, 15, 24 15 66 80-84 470 RB-xx05S RB-xx12S (3,4) (3,4) 3.3, 5, 12, 15, 24 24 42 74-85 220 RB-xx3.3D (3,4) 3.3, 5, 12, 15, 24 3.3 152 70 1000 RB-xx05D (3,4) 3.3, 5, 12, 15, 24 5 100 70-78 1000 RB-xx09D (3,4) 3.3, 5, 12, 15, 24 9 56 76-79 470 RB-xx24S (3,4) 3.3, 5, 12, 15, 24 12 42 78-82 220 RB-xx15D (3,4) 3.3, 5, 12, 15, 24 15 33 80-84 220 3.3, 5, 12, 15, 24 24 21 80-84 100 RB-xx12D RB-xx24D (3,4) (3,4) Notes: Note1: Efficiency is tested at nominal input and full load at +25C ambient Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the capacitive load that will allow start up in under 1s without damage to the converter E358085 UL60950-1 certified CAN/CSA-C22.2 No 60950-1 certified IEC/EN60950-1 certified EN55032 compliant Model Numbering RB- __ nom. Input Voltage Output Voltage / "Protection (4)" "Isolation Option (3)" Single or Dual Notes: Note3: standard part is without Continuous Short Circuit Protection add suffix /P" for Continuous Short Circuit Protection Note4: standard part is with 1kVDC/1s Isolation add suffix /H" for 2kVDC/1s Isolation or add suffix /HP" for 2kVDC/1s Isolation and Continuous Short Circuit Protection Ordering Examples: RB-123.3/P: 12VDC Input Voltage, 3.3VDC Output Voltage, Single Output with continuous short circuit protection and 1kVDC/1s isolation RB-0509D/HP: 5VDC Input Voltage, 9VDC Output Voltage, Dual Output with continuous short circuit protection and 2kVDC/1s isolation www.recom-power.com REV.: 1/2019 ECO-1 RB DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter capacitor Input Voltage Range 10% Minimum Load Internal Operating Frequency 0% 50kHz Output Ripple and Noise 100kHz 105kHz Single output Dual output 20MHz BW 100mVp-p 75mVp-p Efficiency vs. Load RB-xx09S 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] RB-xx05S 60 50 40 30 10 40 0 10 20 30 40 50 60 70 80 90 10 0 100 0 10 20 30 40 50 60 Output Load [%] Output Load [%] RB-xx12S RB-xx15S 100 100 90 90 80 80 70 70 60 50 40 30 70 80 90 100 60 50 40 30 3.312 0512 1212 20 10 0 3.309 0509 1209 20 Efficiency [%] Efficiency [%] 50 30 3.305 0505 1205 20 0 60 0 10 20 30 40 50 60 70 80 90 3.315 0515 1215 20 10 100 0 Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] continued on next page www.recom-power.com REV.: 1/2019 ECO-2 RB DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load otherwise stated) Efficiency vs. Load RB-xx09D 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] RB-xx05D 60 50 40 30 50 40 30 3.305 0505 1205 20 10 0 60 0 10 20 30 40 50 60 70 80 90 3.309 0509 1209 20 10 0 100 0 10 20 30 Output Load [%] 40 60 70 80 90 100 RB-xx15D 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] RB-xx12D 60 50 40 30 60 50 40 30 3.312 0512 1212 20 10 0 50 Output Load [%] 0 10 20 30 40 50 60 70 80 90 3.315 0515 1215 20 10 0 100 0 10 Output Load [%] 20 30 40 50 60 70 80 90 100 Output Load [%] REGULATIONS Parameter Condition Output Accuracy Line Regulation Load Regulation (5) Value 5.0% typ. low line to high line 10% to 100% load 3.3, 5Vout 9, 12, 15, 24Vout 1.2% of 1.0% Vin typ. 15.0% max. 10.0% max. Notes: Note5: Operation below 10% load will not harm the converter, but specifications may not be met continued on next page www.recom-power.com REV.: 1/2019 ECO-3 RB DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load otherwise stated) Deviation vs. Load RB-xx05S 25 3.305 0505 1205 20 15 10 5 10 5 0 0 -5 -5 0 10 20 30 40 50 60 70 80 90 3.309 0509 1209 20 Deviation [%] Deviation [%] 15 -10 RB-xx09S 25 -10 100 0 10 20 30 Output Load [%] 3.312 0512 1212 5 -5 -5 40 50 60 70 80 90 3.315 0515 1215 -10 100 0 10 20 30 Output Load [%] 3.305 0505 1205 5 -5 -5 40 50 60 70 80 90 100 Output Load [%] www.recom-power.com 90 100 3.309 0509 1209 5 0 30 80 10 0 20 70 15 10 10 60 20 Deviation [%] Deviation [%] 15 0 50 RB-xx09D 25 20 -10 40 Output Load [%] RB-xx05D 25 100 5 0 30 90 10 0 20 80 15 10 10 70 20 Deviation [%] Deviation [%] 15 0 60 RB-xx15S 25 20 -10 50 Output Load [%] RB-xx12S 25 40 -10 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] REV.: 1/2019 ECO-4 RB DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load otherwise stated) Deviation vs. Load RB-xx12D RB-xx15D 25 25 3.312 0512 1212 20 15 Deviation [%] Deviation [%] 15 10 5 10 5 0 0 -5 -5 -10 0 10 20 30 40 50 60 70 80 90 3.315 0515 1215 20 -10 100 0 10 20 30 Output Load [%] 40 50 60 70 80 90 100 Output Load [%] PROTECTIONS Parameter Type Short Circuit Protection (SCP) Isolation Voltage (6) Value without suffix with suffix "/P" 1 second continuous without suffix tested for 1 second rated for 1 minute 1kVDC 500VAC/60Hz with suffix "/H" tested for 1 second rated for 1 minute 2kVDC 1kVAC/60Hz 10G min. I/P to O/P Isolation Resistance Isolation Capacitance 20pF min. / 75pF max. basic (IEC/EN60950-1) functional (IEC/EN60601-1) Insulation Grade Notes: Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note7: Refer to local saftey regulations if input over-current protection is also required. Recommended fuse: slow blow type ENVIRONMENTAL Parameter Operating Temperature Range Condition Value full load @ free air convection, refer to "Derating Graph" Maximum Case Temperature +105C Temperature Coefficient 0.03%/K typ. Thermal Impedance 56K/W typ. Operating Altitude Operating Humidity -40C to +85C 3000m non-condensing 95% RH max. Pollution Degree MTBF PD2 according to MIL-HDBK-217F, G.B. +25C +85C 16400 x 10 hours 10200 x 103 hours 3 continued on next page www.recom-power.com REV.: 1/2019 ECO-5 RB DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load otherwise stated) Derating Graph (@ free air convection) 100 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 85 Ambient Temperature [C] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number UL60950-1, 2nd Edition:2007 CAN/CSA C22.2 No. 60950-1-03, 2nd Edition:2007 Information Technology Equipment, General Requirements for Safety E358085-A4-UL Information Technology Equipment, General Requirements for Safety LVD1602031 Medical Electrical Equipment Part 1: General Requirements for Basic Safety and Essential Performance WD-SE-R-180677-A0 EAC Standard IEC60950-1:2005, 2nd Edition + A2:2013 EN60950-1:2006 + A2:2013 IEC60601-1:2005 + A1:2012, 3rd Edition EN60601-1:2006 + A12:2014 RU-AT.49.09571 TP TC 004/2011 RoHS 2 RoHS-2011/65/EU + AM-2015/863 EMC Compliance Electromagnetic compatibility of multimedia equipment Emission requirements Condition Standard / Criterion with external filter (see filter suggestion below) EN55032, Class A and B EMC Filter Suggestion according to EN55032 C2 L1 +Vin +Vin +Vout -Vin -Vout +Vout C1 -Vin -Vout C3 Component List Class A MODEL RB-0505S RB-1205S RB-2405S C1 10F 100V MLCC Component List Class B L1 C2 (safety) C3 (safety) MODEL RB-0505S N/A N/A 2.2nF RB-1205S RB-2405S C1 L1 10F 22H choke 100V MLCC RLS-226 C2 (safety) C3 (safety) 1nF 2.2nF Notes: Note8: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice www.recom-power.com REV.: 1/2019 ECO-6 RB DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load otherwise stated) DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case potting PCB non-conductive black plastic, (UL94 V-0) epoxy, (UL94 V-0) FR4, (UL94 V-0) Dimension (LxWxH) 19.6 x 6.0 x 10.2mm Weight 2.2g typ. Dimension Drawing (mm) embossed logo 19.6 10.2 6.0 Pinning Information Pin # 1 2 4 5 6 0.50 Marking 2.0 4 5 6 5x2.54= 12.70 4.10 Recommended Footprint Details 1.00 O +0.15/-0 2.54 Bottom View 1 2 0.250.05 1.27 0.51+0.10/-0.05 1 2 Single +Vin -Vin NC -Vout +Vout Dual +Vin -Vin -Vout Com +Vout NC = No Connection Tolerance: xx.x= 0.5mm xx.xx= 0.25mm 4 5 6 Top View 2.54 PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 520.0 x 16.0 x 9.0mm Packaging Quantity tube Storage Temperature Range Storage Humidity 25pcs -55C to +125C non-condensing 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 1/2019 ECO-7