WKP Vishay Draloric Ceramic AC Capacitors Class X1, 760 VAC/Class Y1, 500 VAC DESIGN: D Max. S Max. Disc capacitors with epoxy coating (X1): COMPLIANT 760 VAC, 50 Hz (IEC 60384-14.2) (Y1): 500 VAC, 50 Hz (IEC 60384-14.2) L = 30 - 3 or L = 10 1 F 1.0 RoHS RATED VOLTAGE UR: 3 Max. 250 VAC, 60 Hz (UL1414, CSA C22.2) DIELECTRIC STRENGTH BETWEEN LEADS: V 0.5 O d 0.005 * Dimensions in mm Impedance (Z) as a function of frequency (f) at Ta = 20 C (average). Measurement with lead length 6 mm. Component test: 4000 VAC, 50 Hz, 2 s As repeated test admissible only once with 3600 VAC, 50 Hz, 2 s Random sampling test (destructive test): 4000 VAC, 50 Hz, 60 s Z [] DIELECTRIC STRENGTH OF BODY INSULATION: 10 1 4000 VAC, 50 Hz, 60 s (destructive test) DISSIPATION FACTOR tan : 25 * 10-3 10 0 4700 pF 3900 3300 2200 1500 1000 680 470 330 220 150 100 68 47 33 pF INSULATION RESISTANCE Ris: 10 - 1 10 * 109 CATEGORY TEMPERATURE RANGE A: (- 40 to + 125) C CLIMATIC CATEGORY ACC. TO EN60068-1: 10 - 2 1 100 10 300 [MHz] f I~ [A] I = f (UR) (typ.) 40/125/21 COATING: Epoxy dipped, insulating, flame retarding acc. to 800 4.7 nF UL 94V-0 700 TAPING AND SPECIAL LEAD CONFIGURATIONS: 600 3.3 nF On request 500 MARKING: 400 2.2 nF 300 WKP 200 1.0 nF 100 760 ~ X1 500 ~ Y1 47p M WKP 3n3 M IEC 384-14/2 760 500 250 ~ X1 Y1 470 pF 0 1 50 100 150 200 250 300 350 400 UR[V~] WKP 33 pF to 680 pF WKP 1.0 nF to 4.7 nF All approval marks are also shown on the label. www.vishay.com 52 For technical questions, contact slcap@vishay.com Document Number: 22206 Revision: 16-Nov-07 WKP Ceramic AC Capacitors Class X1, 760 VAC/Class Y1, 500 VAC Vishay Draloric ORDERING INFORMATION, CERAMIC X1 / Y1 CAPACITORS WKP CAPACITANCE** (pF) CLASS 1 33 CLASS 2 47 68 CLASS 2 100 CLASS 2 150 220 CLASS 2 330 470 680 1000 1500 2200 3300 3900 4700 TOL. (%) Dxs (mm) F 1* (mm) d 0.05* (mm) V 0.5* (mm) 10 %, 20 % 8.0 x 6.0 12.5 0.6 1.9 WKP330 CP KR 10 %, 20 % 8.0 x 6.0 12.5 0.6 2.3 WKP470 CP WKP680 CP KR KR 10 %, 20 % 8.0 x 6.0 12.5 0.6 2.3 WKP101 CP KR 10 %, 20 % 8.0 x 6.0 12.5 0.6 2.3 WKP151 CP WKP221 CP KR KR 0.6 2.5 0.8 2.7 WKP331 WKP471 WKP681 WKP102 WKP152 WKP222 WKP332 WKP392 WKP472 KR KR KR KR KR KR KR KR KR ORDERING CODE N 750 K 1200 K 1500 K 2000 K 4000 8.0 x 6.0 10 %, 20 % 9.0 x 6.0 10.0 x 6.0 12.0 x 6.0 13.0 x 6.0 15.0 x 6.0 16.0 x 6.0 18.0 x 6.0 12.5 CP CP CP CP CP CP CP CP CP * Standard lead configuration, other lead spacing and diameter available on request. ** Capacitance values from 470 pF to 4700 pF: The alternative usage of smaller VKP series is recommended for new application. ORDERING CODE R 10 % = K 20 % = M 7th digit Capacitance Tolerance: 10th to 12th digit 14th digit Lead Configuration (see General Information) RoHS Compliant Component APPROVALS IEC 60384 - 14 / 2nd Issue (1993) incl. Am. 1 (1995) - Safety Tests EN 132 400 (1994) - Safety Tests That approval together with the CB Test Certificate substitutes the national approval of the following nations: Belgium France Italy Austria China Japan Denmark Greece Luxembourg Portugal Singapore Poland Germany Ireland Netherlands Sweden Slovenia Hungaria Finland Iceland Norway Switzerland Korea Israel Y1 - Capacitor: CB-Test Certificate: DE-1-11002-A1 X1 - Capacitor: CB-Test Certificate: DE-1-11002-A1 Minimum thickness of insulation: 0.4 mm 33 pF ... 4.7 nF 33 pF ... 4.7 nF 500 VAC 760 VAC 33 pF ... 4.7 nF 250 VAC 33 pF ... 4.7 nF 250 VAC Spain United Czech Republic Underwriters Laboratories Inc. UL 1414 Across-the-line, Antenna-coupling and Line-by-pass component. Agency Files / Licences E 183 844 V1 S1 Canadian Standards Association CSA C22.2 Across-the-line, antenna-coupling and line-by-pass component No 1-98 Agency Files / Licences E 183 844 V1 S1 ORDERING INFORMATION WKP SERIES 221 CAP. VALUE Document Number: 22206 Revision: 16-Nov-07 M CP ED0 K R TOLERANCE RATED VOLTAGE LEAD CONFIGURATION INTERNAL CODE RoHS COMPLIANT For technical questions, contact slcap@vishay.com www.vishay.com 53 Legal Disclaimer Notice Vishay Disclaimer All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Vishay"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permitted by law. The product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 18-Jul-08 www.vishay.com 1