NEW
Proximity Sensors
Long-distance Detection of Aluminum or Iron
A Proximity Sensor with a NEW Detection Principle
E2V-X@
Long-distance
Long-distance
aluminum detection
aluminum detection
Long-distance
aluminum detection
Embeddable Embeddable
in metalin metal
Embeddable
in metal
Aluminum chip
Aluminum chip
protection
protection
Aluminum chip
protection
30 Years of Innovation
Click!
1/8th of
a turn
Smartclick
Pre-wired Connector Models
Standard Models
Twice the max.
distance
360° Indicator
360° Indicator
360° Indicator
Aluminum Detection Distance: 1.5 to 2 Times Previous Models
Immunity against aluminum chips has enabled achieving long-distance detection of aluminum
workpieces. The same detection distance has also been achieved for iron, allowing the E2V-X@ to be
separated from workpieces made of either metal farther than any other Proximity Sensor.
*In-house comparison of M18
Shielded Long-distance Models
Detection Made Visible
An operation indicator that is visible from any direction is provided as a standard feature.
This indicator flashes under unstable conditions for easy installation condition verification at a glance.
Embeddable in Metal.
The first Long-distance Sensor that is shielded. Possible to be completely embedded in metal.
01234567
89
Excellent Performance, with Aluminum Chip Immunity!
Embedded Mounting in Metal
E2E
Standard Model
E2EM
Long-distance (Ferrous Metals)
E2EZ
Aluminum Chip Immunity
E2EV
All Metals
E2V
E2EM E2V
Workpiece
Protruding
distance
Bracket
Applications
Long-distance Detection of Crankshafts Cylinder Block Seating Detection Detect Passing Parts
01234567
89
Sensing distance (mm)
Sensing distance (mm)
E2E
E2EM
E2EZ
E2EV
E2V
Aluminum Also Detects Iron at Long Distances!
Iron
×1.5
Previous Sensor
Visible
The indicator
may be difficult
to see from some
directions.
The indicator is
visible from
any direction.
E2V Pre-wired Models
and Pre-wired Connector Models
E2V Connector Models
180° 180° 180°
Workpiece
The indicator is
visible from
any direction.
Ordering Information
Standard-distance Sensors, DC 3-wire, Pre-wired Models (Standard Cable Length: 2 m)
Sensing distance Output Operation mode NO Operation mode NC
Model
Appearance
M12
M18
M30
2mm
5mm
10mm
Shielded
PNP E2V-X2B1 E2V-X2B2
NPN E2V-X2C1 E2V-X2C2
PNP E2V-X5B1 E2V-X5B2
NPN E2V-X5C1 E2V-X5C2
PNP E2V-X10B1 E2V-X10B2
NPN E2V-X10C1 E2V-X10C2
Long-distance Sensors, DC 3-wire, Pre-wired Models (Standard Cable Length: 2 m)
M12
M18
M30
4mm
8mm
15mm
Shielded
PNP E2V-X4B1 E2V-X4B2
NPN E2V-X4C1 E2V-X4C2
PNP E2V-X8B1 E2V-X8B2
NPN E2V-X8C1 E2V-X8C2
PNP E2V-X15B1 E2V-X15B2
NPN E2V-X15C1 E2V-X15C2
Long-distance Sensors, DC 3-wire, Connector Models
M12
M18
M30
4mm
8mm
15mm
Shielded
PNP E2V-X4B1-M1 E2V-X4B2-M1
NPN E2V-X4C1-M1 E2V-X4C2-M1
PNP E2V-X8B1-M1 E2V-X8B2-M1
NPN E2V-X8C1-M1 E2V-X8C2-M1
PNP E2V-X15B1-M1 E2V-X15B2-M1
NPN E2V-X15C1-M1 E2V-X15C2-M1
Long-distance Sensors, DC 3-wire, Smartclick Pre-wired Connector (M12) Models
M12
M18
M30
4mm
8mm
15mm
Shielded
PNP E2V-X4B1-M1TJ
NPN E2V-X4C1-M1TJ
PNP E2V-X8B1-M1TJ
NPN E2V-X8C1-M1TJ
PNP E2V-X15B1-M1TJ
NPN E2V-X15C1-M1TJ
Standard “Twist-and-Click” Connectors
Model Applicable Proximity
Sensor Models
Cable
length (m)
Appearance Type
Standard
cable
Vibration-proof
robot cable
Oil-resistant
polyurethane
cable
2 XS5F-D421-D80-A E2V-X@@@-M1/M1TJ
5 XS5F-D421-G80-A E2V-X@@@-M1/M1TJ
2 XS5F-D421-D80-F E2V-X@@@-M1/M1TJ
5 XS5F-D421-G80-F E2V-X@@@-M1/M1TJ
2 XS5F-D421-D80-P E2V-X@@@-M1/M1TJ
5 XS5F-D421-G80-P E2V-X@@@-M1/M1TJ
Click!
Insert all
the way in. 1/8th of
a turn
Models with 5-m cables are also available and are ordered by adding “5M” to the end of the model number (e.g., E2V-X2B1 5M).
Models with 5-m cables are also available and are ordered by adding “5M” to the end of the model number (e.g., E2V-X4B1 5M).
Smartclick
Connector,
Straight
Sensing distance Output Operation mode NO Operation mode NC
Model
Appearance
Sensing distance Output Operation mode NO Operation mode NC
Model
Appearance
Sensing distance Output Operation mode NO
Model
Appearance
I/O Circuit Diagrams and Timing Charts
Safety Precautions
Engineering Data (Typical)
Ratings and Specifications
Timing chart
Size
Item Model
Sensing distance
Set distance
Differential travel
Detectable object
Standard sensing object
Response frequency*
Power supply voltage
(operating voltage range)
Current consumption
Control Load current
output Residual voltage
Indicators
Operation mode
Protection circuits
Ambient temperature
Ambient humidity
Temperature
influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Cable
Connector
Pre-wired Connector Models
Case
Sensing surface
Clamping nuts
Toothed washer
Accessories
M12 M18 M30
E2V-X2@@ E2V-X4@@ E2V-X5@@ E2V-X8@@ E2V-X10@@ E2V-X15@@
2mm±10% 4mm±10% 5mm±10% 8mm±10% 10mm±10% 15mm±10%
0 to 1.6 mm 0 to 3.2 mm 0 to 4.0 mm 0 to 6.4 mm 0 to 8.0 mm 0 to 12.0 mm
10% max. of sensing distance
Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Typical).)
Aluminum: 12 × 12 × 3 mm Aluminum: 12 × 12 × 3 mm Aluminum: 18 × 18 × 3 mm Aluminum: 24 × 24 × 3 mm Aluminum: 30 × 30 × 3 mm Aluminum: 45 × 45 × 3 mm
150Hz 40Hz 70Hz 40Hz 70Hz 30Hz
12 to 24 VDC (10 to 30 VDC),
ripple (p-p): 10% max.
450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V)
Open-collector output, 100 mA max.
2 V max. (Load current: 100 mA, Cable length: 2 m)
NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit)
B1/C1 Models: NO
B2/C2 Models: NC
Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor
Operating/Storage: 25 to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
Based on the sensing distance at 23°C in the temperature range of −25 to 70°C
±10% max. ±15% max. ±10% max. ±15% max. ±10% max. ±15% max.
±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 M min. (at 500 VDC) between current-carrying parts and case
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.)
Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm)
Approx. 120 g Approx. 150 g Approx. 200 g
Approx. 30 g Approx. 45 g Approx. 120 g
Approx. 50 g Approx. 70 g Approx. 140 g
Nickel-plated brass
Heat-resistant ABS
Nickel-plated brass
Zinc-plated iron
Instruction manual
(Refer to the timing charts under I/O Circuit Diagrams for details.)
E2V-X5
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
0 5 10 15 20 25 30 35 40
0 102030405060
0 102030405060
E2V-X15
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
E2V-X10
0.0
2.0
4.0
6.0
8.0
10.0
12.0
E2V-X4
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0 5 10 15 20 25 30
E2V-X8
0.0
2.0
4.0
6.0
8.0
10.0
0 5 10 15 20 25 30 35 40
Side length of sensing object d (mm) Side length of sensing object d (mm) Side length of sensing object d (mm)
Side length of sensing object d (mm)
Side length of sensing object d (mm)
Side length of sensing object d (mm)
E2V-X2 E2V-X5
E2V-X15
E2V-X10
E2V-X4
E2V-X8
E2V-X2
0.0
0.5
1.0
1.5
2.0
2.5
3.0
0 5 10 15 20 25 30
Sensing distance X (mm)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
0.0
2.0
4.0
6.0
8.0
10.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0123456
0123456
012345678
012345678
024681012 0 2 4 6 8 10 12
+V
0 V
Proximity
Sensor
main
circuit
0 V
Load
+V
Sensing
object
(%) 100 0 80
Flashing
Stable sensing areaNon-sensing area
Unstable
sensing
area
Set position
Proximity sensor
ON
OFF
ON
OFF
Rated
sensing
distance
Sensing
object
(%) 100 0
Non-sensing area
Proximity sensor
ON
OFF
ON
OFF
Sensing area
Ye l l o w
indicator
Control
output
Ye l l o w
indicator
Control
output
E2V-X@C@ (-M1/-M1TJ)
E2V-X@B@ (-M1/-M1TJ)
Note: Connector Models
NO Models:
NC Models:
Compatible Connector Cables: XS5F Series
XS2F Series
Operation mode
NO Models NC Models
M1:
M1TJ:
* The response frequency is an average value.
Measurement conditions are as follows: Standard sensing object, a distance between target objects of twice the size of the standard sensing object, and a set distance of half the sensing distance.
Copper
Aluminum Brass
Iron
Stainless steel
(SUS304)
@d
X
Brass
Aluminum
Iron
Copper
@d
t=3
mm
t=3
mm
X
Brass
Aluminum
Copper
Iron
Stainless steel
(SUS304)
@d
X
Iron
Brass
Aluminum
Copper
Stainless steel
(SUS304)
@d
X
Iron
Brass
Aluminum
Copper
Stainless steel
(SUS304)
@d
X
Stainless steel
(SUS304)
Copper
Brass
Iron
Aluminum
@d
X
Stainless steel
(SUS304)
Copper
Iron
Aluminum Brass
t
X
Sensing object size: 45 × 45 mm
Copper
Brass
Aluminum
Iron
Stainless steel
(SUS304) t
X
Sensing object size: 24 × 24 mm
IronBrass
Aluminum
Copper
Stainless steel
(SUS304)
Thickness of sensing object: t (mm) Thickness of sensing object: t (mm) Thickness of sensing object: t (mm)
Thickness of sensing object: t (mm)Thickness of sensing object: t (mm)
Thickness of sensing object: t (mm)
t
X
Sensing object size: 12 × 12 mm
Iron
Aluminum
Brass
Copper
Stainless steel
(SUS304) t
X
Sensing object size: 18 × 18 mm
Iron
Brass
Aluminum
Copper
Stainless steel
(SUS304)
t
X
Sensing object size: 12 × 12 mm
Brass
Aluminum
Copper
Iron
Stainless steel
(SUS304) t
X
Sensing object size: 30 × 30 mm
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
-12.0 -9.0 -6.0 -3.0 0.0 3.0 6.0 9.0 12.0
Sensing area (aluminum) (Thickness: 3.0 mm)
Sensing distance Y (mm)
-12.0 -9.0 -6.0 -3.0 0.0 3.0 6.0 9.0 12.0
Sensing distance Y (mm)
E2V-X5@
E2V-X4@
E2V-X2@
E2V-X10@
E2V-X8@
E2V-X15@
Sensing area (Iron) (Thickness: 3.0 mm)
E2V-X10@
E2V-X8@
E2V-X4@
E2V-X5@
E2V-X2@
X
Y
X
Y
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
E2V-X15@
t=3
mm
t=3
mm
t=3
mm
t=3
mm
Stainless steel
(SUS304)
This product is not designed or rated for ensuring
safety of persons. Do not use it for such purposes.
Never use the product with an AC power supply.
Otherwise, explosion may result.
WARNING
Influence of Sensing Object Size and Material
Sensing distance X (mm)
Sensing distance X (mm)
Sensing distance X (mm)
Sensing distance X (mm)
Sensing distance X (mm)
Sensing distance X (mm)
Sensing distance X (mm)
Sensing distance X (mm)
Sensing distance X (mm)
Sensing distance X (mm)
Sensing distance X (mm)
Sensing distance X (mm) Sensing distance X (mm)
Influence of Sensing Object Size and Material Sensing Area
Output Circuit Diagrams and Connections
Brown
Black
Blue
Proximity
Sensor
main
circuit
Load
Brown
Black
Blue
Note: Connector Models
NO Models:
NC Models:
Compatible Connector Cables: XS5F Series
XS2F Series
M1:
M1TJ:
Rated
sensing
distance
Weight
(packed
state)
Materials
Influence of Surrounding Metal Mutual Interference
Other Information
A
B
When installing Sensors face-to-face or side-by-side, be sure
that the minimum distances given in table 2 are maintained.
(Unit: mm)
E2V-X2 E2V-X5 E2V-X10
0 0 0
d dia. 12 18 30
D 0 0 0
m 12 24 45
n 18 27 45
Table 1. Influence of Surrounding Metal
When embedding the Sensor in metal, be sure that the
clearances given in the following table are maintained.
m
n
t t t
mD
d dia.
d
DSensing
surface
Cutting
Cutting
Pressed against
sensing surface.
Sensing Distance
The sensing distance depends on the sensing object size, material, and
thickness.
If the sensing object has a thickness of less than 1 mm, the sensing
distance will decrease.
In some cases, it may not be possible to detect stainless steel.
Use the following graph and the Influence of Sensing Object Size and
Material information in Engineering Data (Typical) as a reference.
Aluminum and Iron Cuttings
Normally aluminum or iron cuttings will not be detected even if they adhere
to or accumulate on the sensing surface. Detection signals may be output
for the following. If this occurs, remove the cuttings from the sensing
surface.
Diameter of cutting = d and diameter of sensing surface = D
Cuttings in center of sensing surface
with d 2/3D
Tightening Torque
Do not tighten the nut with excessive force.
A washer must be used with the nut.
Item Model
(Unit: mm)
(Unit: mm)
E2V-X2 E2V-X5 E2V-X10
A 30 50 100
B 20 30 50
Chart 2. Mutual Interference
Item Model
E2V-X4 E2V-X8 E2V-X15
A 35 60 120
B 25 35 70
Item Model
Part A Part B
Dimension(mm) Torque Torque
E2V-X2/X4 17 5.9N•m 9.8N•m
E2V-X5/X8 22 15N•m 45N•m
E2V-X10/X15 26 39N•m 78N•m
Model
Tightening
To r q u e
E2V-X4 E2V-X8 E2V-X15
0 0 0
(See Note 1.)
d dia. 12 18 30 (See Note 1.)
D 0 0 0 (See Note 1.)
m 12 24 45
n 18 27 45
Item Model
D
E2V-X2@/X4@ 10
E2V-X5@/X8@ 16
E2V-X10@/X15@ 28
Model Size
Part B Part A
(Shielded Model)
Dimensions
47
60
4
M12×1 Two clamping nuts
Toothed washer
Indicator*1
6-dia. vinyl-insulated round cable
with 3 conductors
(Conductor cross section: 0.5 mm
2
,
Insulator diameter: 1.9 mm),
Standard length: 2 m
17
21 dia.
42
60
4
52
M18×1 Two clamping nuts
Toothed washer
Indicator*1
6-dia. vinyl-insulated round cable
with 3 conductors
(Conductor cross section: 0.5 mm
2
,
Insulator diameter: 1.9 mm),
Standard length: 2 m
24
29 dia.
E2V-X4@-M1TJ E2V-X8@-M1TJ E2V-X15@-M1TJ
A M12×1 M18×1 M30×1.5
B 60 60 60
C --- 52 52
D 47 42 42
E 21 dia. 29 dia. 42 dia.
F 17 24 36
G 4 4 5
Item Model
Pre-wired Models
Pre-wired Connector Models
Connector Models
Pre-wired Connector Models
E2V-X2/X4
E2V-X5/X8
E2V-X10/X15
E2V-X4@-M1
E2V-X8@-M1
E2V-X15@-M1
47
65
4
M12×1
Two
clamping nuts
Toothed washer Four indicators.*
17
21 dia.
42 dia.
5
44
63
42
M30×1.5
Two
clamping nuts
Toothed washer
36
42
47
60
4
M18×1
Two
clamping nuts
Toothed washer
24
29 dia.
42
60
52
5
M30×1.5
Two clamping nuts
Toothed washer
Indicator*1
6-dia. vinyl-insulated round cable
with 3 conductors
(Conductor cross section: 0.5 mm
2
,
Insulator diameter: 1.9 mm),
Standard length: 2 m
*1 NO Models: Operation indicator (yellow) (flashing)
Setting indicator (yellow) (ON)
NC Models: Operation indicator (yellow) (ON)
* Setting indicator (ON)
Operation indicator (flashing)
36
42 dia.
12.5 dia. 18.5 dia. 30.5 dia.
M12 M18 M30
Proximity Sensor dimensions
Dimension H (mm)
Mounting Hole Dimensions
H
+0.5
0
+0.5
0
+0.5
0
D
C
B
G
6-dia. vinyl-insulated round cable,
Standard length: 300 mm
M12×1
A
Indicator*1
Two clamping nuts
Toothed washer
F
E
M12×1
Four indicators.*
M12×1
52
Four indicators.*
M12×1
49
Note 1: If the thickness of the mounting bracket (t) exceeds 5 mm,
be sure to install the Sensor so that 2, d (dia.) 45, and D 2.
*1 NO Models: Operation indicator (yellow) (flashing)
Setting indicator (yellow) (ON)
NC Models: Operation indicator (yellow) (ON)
This document provides information mainly for selecting suitable models. Please read the document Instruction Sheet carefully for information that the user must understand and accept
before purchase, including information on warranty, limitations of liability, and precautions.
Authorized Distributor:
Note: Specifications subject to change without notice. Cat. No. D107-E1-01
0907
OMRON Corporation
Industrial Automation Company
Sensing Devices Division H.Q.
Industrial Sensors Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7022
Fax: (81)75-344-7107
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen,
Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark, Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
Pu Dong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
(Unit:mm)
2007.10
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
speci ed) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE
HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL
LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR
STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the product.
At the customer's request, OMRON will provide applicable third party certi cation documents identifying ratings and limitations of use that apply to the
products. This information by itself is not suf cient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Disclaimers
CHANGE IN SPECIFICATIONS
Product speci cations and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when signi cant construction changes are made.
However, some speci cations of the product may be changed without any notice. When in doubt, special model numbers may be assigned to x
or establish key speci cations for your application on your request. Please consult with your OMRON representative at any time to con rm actu a l
speci cations of purchased product.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent
the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This catalog shall not be copied for sales or promotions without permission.
This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this
catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.
Cat. No. D107-E1-01