I-2018,www.findernet.com
7
A
60
SERIES
60 SERIES
General purpose relays 6 - 10A
Technical data
Insulation according to EN61810-1 2 pole 3 pole
Nominal voltage of supply system VAC 230/400 230/400
Rated insulation voltage VAC 250 400 250 400
Pollution degree 3 2 3 2
Insulation between coil and contact set
Type of insulation Basic Basic
Overvoltage category III III
Rated impulse voltage kV (1.2/50μs) 4 3.6
Dielectric strength VAC 2000 2000
Insulation between adjacent contacts
Type of insulation Basic Basic
Overvoltage category III III
Rated impulse voltage kV (1.2/50μs) 4 3.6
Dielectric strength VAC 2000 2000
Insulation between open contacts
Type of disconnection Micro-disconnection Micro-disconnection
Dielectric strength VAC/kV (1.2/50μs) 1000/1.5 1000/1.5
Insulation between coil terminals
Rated impulse voltage (surge) differential mode
(according to EN 61000-4-5) kV(1.2/50µs) 4
Other data
Bounce time: NO/NC ms 1/4
Vibration resistance (5…55)Hz: NO/NC g 22/22
Shock resistance g 20
Power lost to the environment without contact current W 1.3 1.3
with rated current W 2.7 (60.12, 60.62) 3.4 (60.13, 60.63)
Contact specification
F 60 - Electrical life (AC) v contact current H 60 - Maximum DC1 breaking capacity
Resistive load - cosφ = 1
Inductive load - cosφ = 0.4
Cycles
contacts in series
DC breaking current (A)
DC voltage (V)
• When switching a resistive load (DC1) having voltage and current values
under the curve, an electrical life of ≥100·103 can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with the
load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
Coil specifications AC coil data
Nominal
voltage
Coil code Operating range Resistance Rated coil
absorption
UNUmin Umax RI at UN (50Hz)
V V V ΩmA
68.006 4.8 6.6 4.6 367
12 8.012 9.6 13.2 19 183
24 8.024 19.2 26.4 74 90
48 8.048 38.4 52.8 290 47
60 8.060 48 66 450 37
110 8.110 88 121 1600 20
120 8.120 96 132 1940 18.6
230 8.230 184 253 7250 10.5
240 8.240 192 264 8500 9.2
400 8.400 320 440 19800 6
DC coil data
Nominal
voltage
Coil code Operating range Resistance Rated coil
absorption
UNUmin Umax RI at UN
V V V ΩmA
69.006 4.8 6.6 28 214
12 9.012 9.6 13.2 110 109
24 9.024 19.2 26.4 445 53.9
48 9.048 38.4 52.8 1770 27.1
60 9.060 48 66 2760 21.7
110 9.110 88 121 9420 11.7
125 9.125 100 138 12000 10.4
220 9.220 176 242 37300 5.8