www.recom-power.com REV.: 3/2019 L-3
AC/DC Converter
Specifications (measured @ Ta= 25°C, 240VAC, rated load unless otherwise specified)
RACT18
Series
-20 -10 0 10 20 30 40 50 60
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
Derating Graph
(@ Chamber and natural convection 0.1m/s)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report Number Standard
Lamp controlgear Part 1: General and safety requirements (CB Scheme) 325797 IEC61347-1:2007 2nd Edition + A2:2012
Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic
controlgear for LED modules (CB Scheme) 325797 IEC61347-2-13:2014 2nd Edition
Lamp controlgear Part 1: General and safety requirements (LVD) EN61347-1:2015
Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic
controlgear for LED modules (LVD) EN61347-2-13:2014 + A1:2017
Lamp controlgear Part 1: General and safety requirements 325797 EN61347-1:2008 + A2:2013
Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic
controlgear for LED modules 325797 EN61347-2-13:2014
EAC RU-AT.49.09571 TP TC 004/2011
RoHS 2+ RoHS 2011/65/EU + AM2015/863
EMC Compliance Condition Standard / Criterion
Limits and methods of measurement of radio disturbance characteristics of electrical
lighting and similar equipment 305985
EN55015:2013 + A1:2015
Equipment for general lighting purposes – EMC immunity requirements
EN61547:2009
Assessment of lighting equipment related to human exposure to electromagnetic fields EN62493:2015
ESD Electrostatic discharge immunity test Air ±8kV, Contact ±4kV EN61000-4-2:2009, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test 3V/m EN61000-4-3:2006 + A2:2010, Criteria A
Fast Transient and Burst Immunity AC Power Port: ±1kV
DC Power Port: ±0.5kV EN61000-4-4:2012, Criteria A
Surge Immunity AC Power Port: ±0.5kV EN61000-4-5:2014, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields 3V/m EN61000-4-6:2014, Criteria A
Voltage Dips and Interruptions Voltage Dips >95% EN61000-4-11:2004, Criteria B
Voltage Dips and Interruptions Voltage Dips 30% EN61000-4-11:2004, Criteria B
Limits of Harmonic Current Emissions EN61000-3-2:2014, Class C
Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013, Clause 5