SR202 - SR215
Current
2.0 A
Voltage
20 V to 150 V
MECHANICAL DATA
2.0 Amp. Schottky Barrier Rectifier
TYPICAL APPLICATIONS
Used in low voltage high frequency inverters, freewheeling,
dc-to-dc converters, and polarity protection applications.
FEATURES
Guarding for overvoltage protection
DO-204AC (DO-15)
Maximum Ratings and Electrical Characteristics at 25 ºC
V
RRM
Maximum Recurrent Peak Reverse Voltage (V)
Maximum RMS Voltage (V)
I
FSM
8.3 ms.Peak Forward Surge Current
V
DC
Maximum DC Blocking Voltage (V)
50 A
V
RMS
T
j
Operating Temperature Range -55°C to +150°C
(Jedec Method)
20
20
14
SR202
40
40
28
SR204
60
60
42
SR206
100
100
70
SR210
150
150
105
SR215
Typical Thermal Resistance
I
F(AV)
Max. Average Forward Rectifier Current (See graphic)
2.0 A
75 °C/W
R
th (j-a)
T
stg
Storage Temperature Range
-55°C to +150°C
Electrical Characteristics at Tamb = 25 °C
0.70 V
V
F
Maximum Instantaneous Forward Voltage
I
F
= 2
.0
A
0.55 V 0.85 V 0.95 V
I
R
10 mA
0.5 mA
15 mA
0.1 mA
2.0 mA
C
j
Typical Junction Capacitance
85 pF120 pF 65 pF
(Note 2)
Maximum D.C. Reverse Current @ Tj = 25 ºC
at Rated DC Blocking Voltage @ Tj = 125 ºC
(Note 3)
(Note 1)
Notes: 1. Pulse Test: 300µ Pulse Width, 1% Duty Cycle
Halogen Free Marking Code
SR202 HF SR204 HF SR206 HF SR210 HF SR215 HF
Low power losses, high efficiency
High surge current capability
Solder dip 260ºC, 10s
Component in accordance to RoHS 2011/65/EU
and WEEE 2002/96/EC
Low forward voltage drop
High frequency operation
Halogen-free available according to IEC 61249-2-21
definition
Marking Code
SR202 SR204 SR206 SR210 SR215
www.fagorelectronica.com
Document Name: sr2 Version: Feb-13
Page Number: 1/4

Case: DO-204AC (DO-15). Epoxy meets UL 94V-0
flammability rating.

Polarity: Color band denotes cathode end.

Terminals:
Matte tin plated leads, solderable per
MIL-STD-750 Method 2026, J-STD-002 and JESD22-B102.
Consumer grade, meets JESD 201 class 1A whisker test
2. Thermal Resistance from Junction to Case per diode
3. Pulse test: Pulse width £ 40ms
Package Outline Dimensions
:
(mm)
SR202 - SR215
2.0 Amp. Schottky Barrier Rectifier
Ordering information
AMP
DO-204AC / DO-15
SR206 AMP
TR
SR206 TR 13" diameter tape and reel 4,000 0.378
AMMO BOX 1,800 0.378
ø0.8±0.1
60.5±0.5
ø3.1±0.5
6.7±0.9
AMP
SR206 HF AMP
TR
SR206 HF TR 13" diameter tape and reel 4,000 0.378
AMMO BOX 1,800 0.378
www.fagorelectronica.com
Document Name: sr2 Version: Feb-13
Page Number: 2/4
PREFERRED P/N PACKAGE CODE DELIVERY MODE BASE QUANTITY UNIT WEIGHT (g)
SR202 - SR215
Ratings and Characteristics (Ta 25 ºC unless otherwise noted)
2.0 Amp. Schottky Barrier Rectifier
0.1
I
F
, instantaneous forward current (A)
1
VF
, forward voltage (V)
0.1 0.5 0.9 1.3 1.7
TYPICAL FORWARD CHARACTERISTIC
20
Tamb, ambient temperature (°C)
0
I
F(AV)
, average forward Current (A)
100
100
MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
50
10
0
10
1
I
FSM
, peak forward surge current (A)
400
10
100.1
Cj, junction capacitance (pF)
2.0
0
1.0
100
20
30
0.3 0.7 1.1 1.5
25 75 150
MAXIMUM FORWARD CURRENT DERATING
CURVE
Number of cycles (Cycle)
100
TYPICAL JUNCTION CAPACITANCE
10
40
V
R
, reverse voltage (V)
17550
1.0
125
SR202-SR206
SR210-SR215
1.5
0.5
1.9 2.1
PULSE WIDTH = 300 µs
1% DUTY CYCLE
Tj = 25 °C
200
80
60
40
20
Transient thermal impedance (°C/W)
TYPICAL REVERSE CHARACTERISTIC TYPICAL TRANSIENT THERMAL IMPEDANCE
Percent of rated peak reverse voltage (%)
I
R
, Instantaneous reverse
current (mA)
0 100
0.1
0.01
0.001
20
20 40 60 80 120
10
140
1
T, Pulse duration (sec)
0.1
100
0.01
1
10
0.1 1 10 100
www.fagorelectronica.com
Document Name: sr2 Version: Feb-13
Page Number: 3/4
SR210
SR202-SR204
SR206
SR215
SR202-SR204
SR206
SR210-SR215
T
j
= 125 °C
T
j
= 75 °C
T
j
= 25 °C SR202-SR204
SR206-SR215
SR202 - SR215
Disclaimer
2.0 Amp. Schottky Barrier Rectifier
www.fagorelectronica.com
Document Name: sr2 Version: Feb-13
Page Number: 4/4
All product, product specifications and data are subject to change without notice to improve reliability,
function or design or otherwise.
Fagor Electrónica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their
behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained
in any datasheet or in any other disclosure relating to any product.
Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular
purpose or the continuing production of any product. To the maximum extent permitted by applicable law,
Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all
liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied
warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge
of typical requirements that are often placed on Fagor products in generic applications. Such statements are not
binding statements about the suitability of products for a particular application. It is the customer's responsibility
to validate that a particular product with the properties described in the product specification is suitable for use in a
particular application. Parameters provided in datasheets and/or specifications may vary in different applications
and performance may vary over time. All operating parameters, including typical parameters, must be validated
for each customer application by the customer's technical experts. Product specifications do not expand or
otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed
therein.
Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or
life-sustaining applications or for any other application in which the failure of the Fagor product could result in
personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such
applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from
and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use
or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding
the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and
conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their
respective owners.