L P V- 6 0 60W Single Output Switching Power Supply series Features : Constant voltage design Universal AC input / Full range Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Over load / Over voltage Cooling by free air convection Fully encapsulated with IP67 level (Note.8) Fully isolated plastic case Class power unit, no FG Class 2 power unit Pass LPS Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices)(Note.7) 100% full load burn-in test Low cost, high reliability 2 years warranty IS 15885(Part 2/Sec13) LPS IP67 R-41027766 THOMAS SAMUEL THOMAS SAMUEL (except for 5V) SPECIFICATION MODEL OUTPUT LPV-60-12 LPV-60-15 LPV-60-24 LPV-60-36 LPV-60-48 DC VOLTAGE 5V 12V 15V 24V 36V 48V RATED CURRENT 8A 5A 4A 2.5A 1.67A 1.25A CURRENT RANGE 0 ~ 8A 0 ~ 5A 0 ~ 4A 0 ~ 2.5A 0 ~ 1.67A 0 ~ 1.25A RATED POWER 40W 60W 60W 60W 60W 60W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 150mVp-p 150mVp-p 150mVp-p VOLTAGE TOLERANCE Note.3 8.0% 5.0% 1.0% LINE REGULATION 6.0% LOAD REGULATION SETUP, RISE TIME VOLTAGE RANGE 50ms/230VAC Note.4 90 ~ 264VAC 47 ~ 63Hz EFFICIENCY (Typ.) 76% AC CURRENT (Typ.) INRUSH CURRENT(Typ.) 1.2A/115VAC 1A/230VAC COLD START 60A(twidth=525s measured at 50% Ipeak) at 230VAC MAX. No. of PSUs on 16A CIRCUIT BREAKER 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING NOTE 16ms/115VAC at full load 127 ~ 370VDC FREQUENCY RANGE LEAKAGE CURRENT OTHERS 2.0% Note.6 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V) HOLD UP TIME (Typ.) INPUT (for 12V,24V only) (for 48V only) (except for 5V,48V) LPV-60-5 83% 83% 86% 86% 86% 41.4 ~ 48.6V 55.2 ~ 64.8V 0.25mA / 240VAC 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +80, 10 ~ 95% RH 0.03%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), BIS IS15885(for LPV-60-12,LPV-60-24 only), EAC TP TC 004, IP67, IEC60950-1:2005+A2:2013 approved ; design refer to TUV EN60950-1 I/P-O/P:3KVAC I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55032 (CISPR32) Class B, EN61000-3-2 Class A, EN61000-3-3, EAC TP TC 020 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020 732Khrs min. MIL-HDBK-217F (25) 162.5*42.5*32mm (L*W*H) 0.4Kg; 32pcs/13.8Kg/0.56CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit. 8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute. 9. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 10.Products sourced from the Americas regions may not have the BIS logo. Please contact your MEAN WELL sales for more information. 11. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf File Name:LPV-60-SPEC 2019-01-25 L P V- 6 0 60W Single Output Switching Power Supply Mechanical Specification Case No. 976A 60030 series Unit:mm 60030 162.5 3.6 42.5 3.5 15 UL1015 18AWG AC/N(Blue) AC/L(Brown) 3.6 81.5 T case 3.5 3.5 UL1007 16AWG +V(Red) -V(Black) 3.5 32 T case: Max. Case Temperature. Recommend Mounting Direction Block Diagram fosc : 65KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING O.L.P. +V -V DETECTION CIRCUIT PWM CONTROL O.V.P. Derating Curve Static Characteristics 100 100 230VAC 90 80 60 LOAD (%) LOAD (%) 80 115VAC 40 70 60 50 20 -30 40 -15 0 15 30 40 50 AMBIENT TEMPERATURE () 60 70 (HORIZONTAL) 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:LPV-60-SPEC 2019-01-25