SPECIFICATION
MODEL LPV-60-5 LPV-60-12 LPV-60-15 LPV-60-24 LPV-60-36 LPV-60-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
5V 12V 15V 24V 36V 48V
8A 5A 4A 2.5A 1.67A 1.25A
0 ~ 8A 0 ~ 5A 0 ~ 4A 0 ~ 2.5A 0 ~ 1.67A 0 ~ 1.25A
40W 60W 60W 60W 60W 60W
80mVp-p 120mVp-p 120mVp-p 150mVp-p 150mVp-p 150mVp-p
±8.0%
±1.0%
±6.0%
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
76% 83%
±2.0%
±5.0%
83% 86% 86% 86%
5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 41.4 ~ 48.6V 55.2 ~ 64.8V
1.2A/115VAC 1A/230VAC
COLD START 60A(twidth=525 s measured at 50% Ipeak) at 230VACμ
0.25mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2 Class A, EN61000-3-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
732Khrs min. MIL-HDBK-217F (25 )
162.5*42.5*32mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
10.Products sourced from the Americas regions may not have the BIS logo. Please contact your MEAN WELL sales for more information.
11. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
0.4Kg; 32pcs/13.8Kg/0.56CUFT
Protection type : Shut down o/p voltage, re-power on to recover
60W Single Output Switching Power Supply
Features :
LPV-60 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
File Name:LPV-60-SPEC 2019-01-25
Constant voltage design
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Over load / Over voltage
Cooling by free air convection
Fully encapsulated with IP67 level (Note.8)
Fully isolated plastic case
Class power unit, no FG
Class 2 power unit
ass LPSP
Suitable for LED related fixture or appliance
(such as LED Decoration or Advertisement devices)(Note.7)
100% full load burn-in test
Low cost, high reliability
2 years warranty
500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V)
50ms/230VAC 16ms/115VAC at full load
EMC IMMUNITY
EMC EMISSION
IP67
MAX. No. of PSUs on 16A
CIRCUIT BREAKER 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LPS
(except for 5V) (for 48V only) (except for 5V,48V)
IS 15885(Part 2/Sec13)
R-41027766
THOMAS SAMUEL
THOMAS SAMUEL
(for 12V,24V only)
UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48),
CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), BIS IS15885(for LPV-60-12,LPV-60-24 only),
EAC TP TC 004, IP67, IEC60950-1:2005+A2:2013 approved ; design refer to TUV EN60950-1
Mechanical Specification
File Name:LPV-60-SPEC 2019-01-25
fosc : 65KHz
PWM
O.L.P.
EMI FILTER
RECTIFIERS
POWER
SWITCHING FILTER
&
RECTIFIERS +V
-V
I/P
CONTROL
&
Block Diagram
+V(Red)
-V(Black)
600 30±
ψ3.6
ψ3.6
162.5
3.5
3.5
3.5
3.5
42.5
600 30±
32
DETECTION
CIRCUIT
O.V.P.
230VAC
115VAC
AC/N(Blue)
AC/L(Brown)
Recommend Mounting Direction
T case: Max. Case Temperature.
81.5
Tcase
15
UL1007 16AWG
UL1015 18AWG
20
40
60
80
100
INPUT VOLTAGE (V) 60Hz
90 100 125 135 145 155 165 175 180 200 230 264
100
90
80
70
60
50
40
Derating CurveDerating Curve Static Characteristics
AMBIENT TEMPERATURE ( )
LOAD (%)
175
LOAD (%)
60W Single Output Switching Power Supply LPV-60 series
(HORIZONTAL)
-15 0 15 30
04050-30 60 70
Case No. 976A Unit:mm