______________________________________________________________________________________________________________________________ 1 of 3
SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 • Phone 805.486.4565 • Fax 858.712.2040 • Email: info@slpower.com • www.slpower.com
100-240VAC, 50/60 Hz, single phase
80-270VAC, 45-65 Hz max
500 ms max
120VAC: 3A. 230VAC: 1.5A
See chart
Limited by internal thermistor. The inrush at 240Vac,
averaged over the first AC half-cycle under cold start
conditions will not exceed 38A.
Keeping the following components below
these temps indicates sufficient cooling:
Q1: 90°C max., T4: 110°C max
F1 and F2, 4A/250V
3.5% max
0.98 typical, 0.96 minimum
Cycling type, 250W nominal limit
100µA at 120VAC NC, 400µA at 264VAC, SFC
See chart
200W continuous with 200lfm airflow
See chart for convection ratings
1% pk-pk max., 20MHz BW,
0.1µF and 10 µF caps on probe
240W for 1 minute, 10% duty cycle
CSA/EN/IEC/UL 60950-1, 2
Edition
See chart
EN/IEC/UL 60601-1, CSA22.2 No. 601-1
Adjustable potentiometer, capable of
±5% change from the nominal setting
Output: 195kHz ±12kHz, PFC: 130kHz
Not required
300K hours per Telcordia
See chart
Overtemperature Protection
Automatic
500µs to 1%, 50% load step, ∆i/∆t < 0.2A/µ
Maximum voltage deviation is 3.5%
90% typical at 230VAC, 87% typical at 120VAC
Temperature Coefficient 0.03% per
C typical on all units Operating Temperature 0 to 70
C (see chart)
500 to 10,000 ft
Storage Temperature -40 to +85
C
-500 to 40,000 ft
5% to 95%, non-condensing
5 Hz – 500 Hz, 5 grms
MIL-STD-810E, 516.4 part IV
Model Number Key
GNT
Product Family (GNT = Class I input, G2T = Class II input)
2
Output Pow er (Watts): "2" = 200W
XX
Output Voltage: (See models chart below )
X
Enclosure Options: Blank - no enclosure; F = Fan Cover w ith "U" channel; L = L
bracket, no cover; T = Slotted cover w ith U channel; U = U channel, no cover.
G
GNT200
Front End Series 200W AC/DC
Universal Input Power Supply 2 Year Warranty
•Wide Range Input 100-240 VAC with PFC
•Inhibit, Enable, Power Signals and Remote Sense Standard
•Power Density 10-13W/in³
•Compact (3.0” x 5.0” x 1.25”)
•High Efficiency: 90% Typical
•Main Output and Two Auxiliary Outputs
•Conducted EMI meets Class B
•Approved to CSA/EN/IEC/UL 60950-1, 2
nd
Edition for ITE
•Approved to EN/IEC/UL60601-1 and CSA 22.2 No. 601 for Medical
•Also Available in Class II (G2T200)
•CB Report Available (for IEC60601-1 standard)
Specifications
All Specifications are typical at nominal input, full load at 25
°
C unless otherwise stated.