REVISIONS
LTR DESCRIPTION DATE (YR-MO-DA) APPROVED
A
Changes in accordance with NOR 5962-R231-93. 93-09-21 M. A. Frye
B
Updated boilerplate. Added device types 03-05.
Removed programming requirements from drawing.
TABLE I. changes. Editorial changes throughout.
94-08-19 M. A. Frye
C
Boilerplate update, part of 5 year review. ksr 07-01-30 Joseph Rodenbeck
REV
SHEET
REV
SHEET
REV STATUS REV C C C C C C C C C C C
OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11
PMIC N/A PREPARED BY
James E. Jamison
DEFENSE SUPPLY CENTER COLUMBUS
STANDARD
MICROCIRCUIT
DRAWING
CHECKED BY
Ray Monnin
COLUMBUS, OHIO 43218-3990
http://www.dscc.dla.mil
THIS DRAWING IS AVAILABLE
FOR USE BY ALL
DEPARTMENTS
APPROVED BY
Michael A. Frye
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
DRAWING APPROVAL DATE
88-09-22
MICROCIRCUIT, MEMORY,
DIGITAL, CMOS, 1K X 8
REGISTERED PROM,
MONOLITHIC SILICON
AMSC N/A
REVISION LEVEL
C SIZE
A CAGE CODE
67268
5962-88636
SHEET
1 OF
11
DSCC FORM 2233
APR 97 5962-E204-07
.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-88636
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
C SHEET 2
DSCC FORM 2234
APR 97
1. SCOPE
1.1 Scope. This drawing describes device requirements for MIL-STD-883 compliant, non-JAN class level B microcircuits in
accordance with MIL-PRF-38535, appendix A.
1.2 Part or Identifying Number (PIN). The complete PIN is as shown in the following example:
5962-88636 01 K A
Drawing number Device type
(see 1.2.1) Case outline
(see 1.2.2) Lead finish
(see 1.2.3)
1.2.1 Device type(s). The device type(s) identify the circuit function as follows:
Device type Generic number 1/ Circuit function Access time
01 7C235 1K X 8-bit registered PROM 40
02 7C235 1K X 8-bit registered PROM 30
03 7C235A 1K X 8-bit registered PROM 40
04 7C235A 1K X 8-bit registered PROM 30
05 7C235A 1K X 8-bit registered PROM 25
1.2.2 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter Descriptive designator Terminals Package style
K CDFP3-F24 or GDFP2-F24 24 flat package
L CDIP4-T24 or GDIP3-T24 24 Dual-in-line
3 CQCC1-N28 28 Square chip carrier
1.2.3 Lead finish. The lead finish is as specified in MIL-PRF-38535, appendix A.
1.3 Absolute maximum ratings.
Supply voltage range to ground potential (VCC)--------------------------- -0.5 V dc to +7.0 V dc
DC voltage range applied to the outputs in the high Z state----------- -0.5 V dc to +7.0 V dc
DC input voltage - - - - - - - - - - - - - - - - - - - - - -------------------------- -3.0 V dc to +7.0 V dc
Maximum power dissipation ------------------------------------------------- 1.0 W 3/
Lead temperature (soldering, 10 seconds) ------------------------------- +260°C
Thermal resistance, junction-to-case (θJC) - - - - - - - - - --------------- See MIL-STD-1835
Junction temperature (TJ) - - - - - - - - - - - - - - - - - - ------------------- +150°C 4/
Storage temperature range (TSTG) - - - - - - - - - - - - - - ---------------- -65°C to +150°C
Temperature under bias ------------------------------------------------------- -55°C to +125°C
Data retention -------------------------------------------------------------------- 10 years, minimum
1.4 Recommended operating conditions.
Supply voltage range (VCC)---------------------------------------------------- +4.5 V dc minimum to +5.5 V dc maximum
Ground voltage (GND) -------------------------------------------------------- 0 V dc
Input high voltage range (VIH) ------------------------------------------------ +2.0 V dc to VCC
Input low voltage range (VIL) -------------------------------------------------- -0.5 V dc to +0.8 V dc
Case operating temperature range (TC) ----------------------------------- -55°C to +125°C
1/ Generic numbers are also listed on the Standard Microcircuit Drawing Source Approval Bulletin and
in MIL-HDBK-103.
2/ Unless otherwise specified, all voltages are referenced to ground.
3/ Must withstand the added PD due to short circuit test; e.g., IOS.
4/ Maximum junction temperature may be increased to +175°C during burn-in and steady state life tests.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-88636
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
C SHEET 3
DSCC FORM 2234
APR 97
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a
part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in
the solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATION
MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883 - Test Method Standard Microcircuits.
MIL-STD-1835 - Interface Standard Electronic Component Case Outlines.
DEPARTMENT OF DEFENSE HANDBOOKS
MIL-HDBK-103 - List of Standard Microcircuit Drawings.
MIL-HDBK-780 - Standard Microcircuit Drawings.
(Copies of these documents are available online at http://assist.daps.dla.mil/quicksearch/ or http://assist.daps.dla.mil or from
the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535, appendix A for non-
JAN class level B devices and as specified herein. Product built to this drawing that is produced by a Qualified Manufacturer
Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional certification to MIL-
PRF-38535 may be processed as QML product in accordance with the manufacturers approved program plan and qualifying
activity approval in accordance with MIL-PRF-38535. This QML flow as documented in the Quality Management (QM) plan
may make modifications to the requirements herein. These modifications shall not affect form, fit, or function of the device.
These modifications shall not affect the PIN as described herein. A "Q" or "QML" certification mark in accordance with MIL-
PRF-38535 is required to identify when the QML flow option is used.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as
specified in MIL-PRF-38535, appendix A and herein.
3.2.1 Terminal connections. The terminal connections shall be as specified on figure 1.
3.2.2 Truth table. The truth table shall be as specified on figure 2.
3.2.2.1 Unprogrammed devices. The truth table for unprogrammed devices for contracts involving no altered item drawing
shall be as specified on figure 2. When required in groups A, B, C, or D (see 4.3), the devices shall be programmed by the
manufacturer prior to test with a minimum of 50 percent of the total number of gates programmed or to any altered item
drawing pattern which includes at least 25 percent of the total number of gates programmed.
3.2.2.2 Programmed devices. The truth tables for programmed devices shall be as specified by an attached altered item
drawing.
3.2.3 Case outlines. The case outlines shall be in accordance with 1.2.2 herein.
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full case operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are described in table I.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-88636
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
C SHEET 4
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics.
Test
Symbol
Group A
subgroups
Device
type
Limits
Unit
Conditions
-55°C TC +125°C
4.5 V VCC 5.5 V
unless otherwise specified Min Max
Output high voltage VOH V
CC =Min, IOH = -4.0 mA, 1, 2, 3 All 2.4 V
V
IN = VIH or VIL
Output low voltage VOL V
CC = Min, IOL = 16.0 mA, 1, 2, 3 All 0.4 V
V
IN = VIH or VIL
Input high voltage
VIH 1/ 1, 2, 3 All 2.0 V
Input low voltage
VIL 1/ 1, 2, 3 All 0.8 V
Input leakage current
IIX V
CC =Max
VIN = 5.5 V and GND 1, 2, 3 All -10 10 µA
Output leakage current IOZ V
CC = Max 1, 2, 3 All -10 10 µA
V
OUT = 5.5 V and GND 2/
Outputs disabled
Output short circuit IOS V
CC = Max 3/, 4/ 1, 2, 3 All -20 -90 mA
current VOUT = GND
ICC V
CC = Max 1, 2, 3 All 120 mA Power supply current I
OUT = 0 mA
Input capacitance CIN V
CC = 5.0 V 4 All 10 pF
TC = +25°C
f = 1 MHz VIN = 0 V
Output capacitance
COUT (see 4.3.1c) VOUT = 0 V 4 All 10 pF
Functional tests
See 4.3.1e 7, 8A, 8B All
Address setup to clock tSA 9, 10, 11 01, 03 40 ns
high 02, 04 30
5/ 05 25
Address hold from clock tHA 9, 10, 11 ns
high
All 0
Clock high to output tCO 9, 10, 11 01, 03 20 ns
valid 02, 04 15
05 12
Clock pulse width tPWC 9, 10, 11 01, 03 20 ns
02, 04 15
05 12
Es setup to clock high tSEs 9, 10, 11 01, 03 15 ns
02, 04
05 10
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-88636
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
C SHEET 5
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Conditions
-55°C TC +125°C
4.5 V VCC 5.5 V
Group A
subgroups
Device
type
Limits
Unit
unless otherwise specified Min Max
Es hold from clock
high tHEs 5/ 9, 10, 11 All 5
ns
Inactive to valid output tCOS 9, 10, 11 01, 03 25 ns
from clock high 6/ 02, 04,
05 20
Inactive output from tHZC 9, 10, 11 01, 03 25 ns
clock high 3/, 6/, 7/ 02, 04,
05 20
Valid output from E low tDOE 9, 10, 11 01, 03 25 ns
8/ 02, 04,
05 20
Inactive output from E tHZE 9, 10, 11 01, 03 25 ns
high 3/, 7/, 8/ 02, 04,
05 20
Delay from INIT to tDI 9, 10, 11 01, 03 35
valid output 3/ 02, 04,
05 25 ns
INIT recovery to clock
high 3/ tRI 9, 10, 11 All 20
ns
INIT pulse width tPWI 9, 10, 11 01, 03 25
3/ 02, 04,
05 20 ns
1/ These are absolute values with respect to device ground pin and include all overshoots due to system or tester
noise. Do not attempt to test these values without suitable equipment.
2/ For devices using synchronous enable, the device must be clocked after applying these voltages to perform this
measurement.
3/ These parameters may not be tested, but shall be guaranteed to the limits specified in table I.
4/ For test purposes, not more than one output at a time should be shorted. Short circuit test duration should not exceed
30 seconds.
5/ AC tests are performed with input rise and fall times of 5 ns or less, timing reference levels of 1.5 V, input pulse levels of
0 V to 3.0 V, output loading of the specified IOL or IOH and 50 pF load capacitance. See figure 3.
6/ Applies only when the synchronous Es function is used.
7/ Transition is measured at steady state high level -500 mV or steady state low level +500 mV on the output from the
1.5 V level on the input and 5 pF load capacitance. See figure 3.
8/ Applies only when the asynchronous E function is used.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-88636
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
C SHEET 6
DSCC FORM 2234
APR 97
3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN
listed in 1.2 herein. In addition, the manufacturer's PIN may also be marked. For packages where marking of the entire SMD
PIN number is not feasible due to space limitations, the manufacturer has the option of not marking the "5962-" on the device.
3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in
compliance to MIL-PRF-38535, appendix A. The compliance indicator “C” shall be replaced with a "Q" or "QML" certification
mark in accordance with MIL-PRF-38535 to identify when the QML flow option is used.
3.6 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an
approved source of supply in MIL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DSCC-VA prior to
listing as an approved source of supply shall affirm that the manufacturer's product meets the requirements of MIL-PRF-
38535, appendix A and the requirements herein.
3.7 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38535, appendix A shall be provided
with each lot of microcircuits delivered to this drawing.
3.8 Notification of change. Notification of change to DSCC-VA shall be required for any change that affects this drawing.
3.9 Verification and review. DSCC, DSCC's agent, and the acquiring activity retain the option to review the manufacturer's
facility and applicable required documentation. Offshore documentation shall be made available onshore at the option of the
reviewer.
3.10 Processing options. Since the device is capable of being programmed by either the manufacturer or the user to result
in a wide variety of configurations; two processing options are provided for selection in the contract, using an altered item
drawing.
3.10.1 Unprogrammed device delivered to the user. All testing shall be verified through group A testing as defined in
3.2.2.1 and table II. It is recommended that users perform subgroups 7 and 9 after programming to verify the specific program
configuration.
3.10.2 Manufacturer-programmed device delivered to the user. All testing requirements and quality assurance provisions
herein, including the requirements of the altered item drawing, shall be satisfied by the manufacturer prior to delivery.
3.11 Data retention. A data retention stress test shall be completed as part of the vendor's reliability monitors.
This test shall be done initially and after any design or process change which may affect data retention. The methods and
procedures may be vendor specific, but will guarantee the number of years listed in section 1.3 herein over the
full military temperature range. The vendor's procedure shall be kept under document control and shall be made
available upon request.
4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535,
appendix A.
4.2 Screening. Screening shall be in accordance with method 5004 of MIL-STD-883, and shall be conducted on all
devices prior to quality conformance inspection. The following additional criteria shall apply:
a. Burn-in test, method 1015 of MIL-STD-883.
(1) Test condition C or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify
the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method
1015 of MIL-STD-883.
(2) TA = +125°C, minimum.
b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter
tests prior to burn-in are optional at the discretion of the manufacturer.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-88636
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
C SHEET 7
DSCC FORM 2234
APR 97
4.3 Quality conformance inspection. Quality conformance inspection shall be in accordance with method 5005 of MIL-
STD-883 including groups A, B, C, and D inspections. The following additional criteria shall apply.
4.3.1 Group A inspection.
a. Tests shall be as specified in table II herein.
b. Subgroups 5 and 6 in table I, method 5005 of MIL-STD-883 shall be omitted.
c. Subgroup 4 (CIN and COUT measurement) shall be measured only for the initial test and after process or design
changes which may affect capacitance. Sample size is fifteen devices with no failures and all input and output
terminals tested.
d. Unprogrammed devices shall be tested for programmability and ac performance compliance to the requirements of
group A, subgroups 9, 10, and 11. Either of two techniques is acceptable:
(1) Testing the entire lot using additional built-in test circuitry which allows the manufacturer to verify
programmability and ac performance without programming the user array. If this is done, the resulting test
patterns shall be verified on all devices during subgroups 9, 10, and 11, group A testing in accordance with
the sampling plan specified in MIL-STD-883, method 5005.
(2) If such compliance cannot be tested on an unprogrammed device, a sample shall be selected to satisfy
programmability requirements prior to performing subgroups 9, 10, and 11. Twelve devices shall be
submitted to programming (see 3.2.2.2). If more than two devices fail to program, the lot shall be rejected.
At the manufacturer's option, the sample may be increased to 24 total devices with no more than 4 total
device failures allowable. Ten devices from the programmability sample shall be submitted to the
requirements of group A, subgroups 9, 10, and 11. If more than two devices fail, the lot shall be rejected.
At the manufacturer's option, the sample may be increased to 20 total devices with no more than 4 total
device failures allowable.
e. Subgroups 7 and 8 shall include verification of the truth table.
4.3.2 Groups C and D inspections.
a. End-point electrical parameters shall be as specified in table II herein.
b. Steady-state life test conditions, method 1005 of MIL-STD-883.
(1) Test condition C or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified
in method 1005 of MIL-STD-883.
(2) TA = +125°C, minimum.
(3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
c. Group C, subgroup 1 sample shall include devices tested in accordance with 4.3.1d.
4.4 Programming procedures. The programming procedures shall be as specified by the device manufacturer.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-88636
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
C SHEET 8
DSCC FORM 2234
APR 97
Device types All
Case outlines K, L 3
Terminal
number
Terminal
symbol
1 A7 NC
2 A6 A
7
3 A5 A
6
4 A4 A
5
5 A3 A
4
6 A2 A
3
7 A1 A
2
8 A0 A
1
9 O0 A
0
10 O1 NC
11 O2 O
0
12 GND O1
13 O3 O
2
14 O4 GND
15 O5 NC
16 O6 O
3
17 O7 O
4
18 CP O5
19 Es O6
20 INIT O7
21 E NC
22 A9 CP
23 A8 Es
24 VCC INIT
25 ---
E
26 --- A9
27 --- A8
28 ---
VCC
NC = no connection
FIGURE 1. Terminal connections.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-88636
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
C SHEET 9
DSCC FORM 2234
APR 97
Read or Output disable A2 CP Es INIT E A1 Outputs
Mode Read 1/ 2/ 3 X X VIL V
IH V
IL X Data out
Output disable 1/ 4/ X X VIH V
IH X X High Z
Output disable 1/ X X X VIH V
IH X High Z
INIT 1/ 5/ X X X VIL V
IL X 1025th
word
1/ X = don't care, but not to exceed VPP = 13.0 V, maximum.
2/ During read operation, the output latches are loaded on a "0" to "1" transition of CP.
3/ Pin 19 must be LOW prior to the "0" to "1" transition on CP (18) that loads the register.
4/ Pin 19 must be HIGH prior to the "0" to "1" transition on CP (18) that loads the register.
5/ Low to high clock transition required to enable outputs.
FIGURE 2. Truth table.
NOTES:
1. CL includes probe and jig capacitance. CL = 50 pF for all switching characteristics except tHZC and tHZE.
C
L = 5 pF for tHZC and tHZE.
2. Tests are performed with rise and fall times of 5 ns or less.
3. All device test loads should be located within two inches of device outputs.
FIGURE 3. Output load circuit and test conditions.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-88636
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
C SHEET 10
DSCC FORM 2234
APR 97
NOTE: Transition is measured at steady-state high level -500 mV or steady-state low level +500 mV on the
output, from the 1.5 V level on the input and 5 pF load capacitance. See figure 3.
FIGURE 4. Switching waveforms.
STANDARD
MICROCIRCUIT DRAWING
SIZE
A
5962-88636
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
C SHEET 11
DSCC FORM 2234
APR 97
TABLE II. Electrical test requirements. 1/ 2/ 3/ 4/
MIL-STD-883 test requirements Subgroups
(per method
5005, table I)
Interim electrical parameters
(method 5004)
---
Final electrical test parameters
(method 5004) f
1*, 2, 3, 7*, 8A, 8B,
9, 10,11
Group A test requirements
(method 5005)
1,2,3,4**,7,8A,8B,
9, 10,11
Groups C and D end-point electrical
parameters (method 5005)
2, 3, 7, 8A, 8B
1/ * indicates PDA applies to subgroups 1 and 7.
2/ Any or all subgroups may be combined when using high-speed testers.
3/ ** see 4.3.1c.
4/ As a minimum, subgroups 7 and 8 shall consist of verifying the data pattern.
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-
prepared specification or drawing.
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
6.4 Record of users. Military and industrial users shall inform Defense Supply Center Columbus (DSCC) when a system
application requires configuration control and the applicable SMD. DSCC will maintain a record of users and this list will be
used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronics devices (FSC
5962) should contact DSCC-VA, telephone (614) 692-0544.
6.5 Comments. Comments on this drawing should be directed to DSCC-VA, Columbus, Ohio 43218-3990, or telephone
(614) 692-0547.
6.6 Approved sources of supply. Approved sources of supply are listed in MIL-HDBK-103. The vendors listed in MIL-
HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been submitted to and accepted
by DSCC-VA.
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 07-01-30
Approved sources of supply for SMD 5962-88636 are listed below for immediate acquisition information only and shall
be added to MIL-HDBK-103 and QML-38535 during the next revision. MIL-HDBK-103 and QML-38535 will be revised
to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a certificate
of compliance has been submitted to and accepted by DSCC-VA. This information bulletin is superseded by the next
dated revision of MIL-HDBK-103 and QML-38535. DSCC maintains an online database of all current sources of
supply at http://www.dscc.dla.mil/Programs/Smcr/.
Standard
microcircuit
drawing PIN 1/
Vendor
CAGE
number
Vendor
similar PIN 2/
5962-8863601KA 3/
0C7V7
0C7V7
CY7C235-40KMB
7C235A-40
QP7C235A-40KMB
5962-8863601LA 3/
0C7V7
0C7V7
CY7C235-40DMB
7C235A-40
QP7C235A-40DMB
5962-88636013A 3/
0C7V7
0C7V7
CY7C235-40LMB
7C235A-40
QP7C235A-40LMB
5962-8863602KA 3/
0C7V7
0C7V7
CY7C235-30KMB
7C235A-30
QP7C235A-30KMB
5962-8863602LA 3/
0C7V7
0C7V7
CY7C235-30DMB
7C235A-30
QP7C235A-30DMB
5962-88636023A 3/
0C7V7
0C7V7
CY7C235-30LMB
7C235A-30
QP7C235A-30LMB
5962-8863603KA 3/
0C7V7
0C7V7
CY7C235A-40KMB
7C235A-40
QP7C235A-40KMB
5962-8863603LA 65786
0C7V7
CY7C235A-40DMB
QP7C235A-40DMB
5962-88636033A 3/
0C7V7
0C7V7
CY7C235A-40LMB
7C235A-40
QP7C235A-40LMB
5962-8863604KA 3/
0C7V7
0C7V7
CY7C235A-30KMB
7C235A-30
QP7C235A-30KMB
5962-8863604LA 3/
3/
0C7V7
CY7C235A-30DMB
7C235A-30
QP7C235A-30DMB
5962-88636043A 3/
0C7V7
0C7V7
CY7C235A-30LMB
7C235A-30
QP7C235A-30LMB
See footnotes at end of table.
Page 1 of 2
STANDARD MICROCIRCUIT DRAWI NG BULLETIN – Continued.
Standard
microcircuit
drawing PIN 1/
Vendor
CAGE
number
Vendor
similar PIN 2/
5962-8863605KA 3/
0C7V7
0C7V7
CY7C235A-25KMB
7C235A-25
QP7C235A-25KMB
5962-8863605LA 3/
0C7V7
0C7V7
CY7C235A-25DMB
7C235A-25
QP7C235A-25DMB
5962-88636053A 3/
0C7V7
0C7V7
CY7C235A-25LMB
7C235A-25
QP7C235A-25LMB
1/ The lead finish shown for each PIN representing a hermetic package
is the most readily available from the manufacturer listed for that
part. If the desired lead finish is not listed, contact the Vendor to
determine its availability.
2/ Caution: Do not use this number for item acquisition. Items
acquired to this number may not satisfy the performance
requirements of this drawing.
3/ Not available from an approved source.
Vendor CAGE Vendor name
number and address
0C7V7 QP Semiconductor
2945 Oakmead Village Court
Santa Clara, CA 95051
65786 Cypress Semiconductor
3901 North First Street
San Jose, CA 95134-1506
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in the
information bulletin.
Page 2 of 2