4
Absolute Maximum Ratings
Description Symbol Min. Max. Unit
Storage Temperature, Ambient TS -65 +100 °C
Operating Temperature, Ambient[1] TA -55 +85 °C
Supply Voltage[2] VCC -0.5 +7.0 V
Voltage Applied to Input Logic, dp and Enable Pins VI, VDP , VE -0.5 VCC V
Voltage Applied to Blanking Input[2] VB -0.5 VCC V
Soldering Temperature [1.59 mm (0.063 inch) Below Body]
Solder Dipping, max. 5 Seconds 260 °C
Wave Soldering, max. 3 Seconds 250 °C
Recommended Operating Conditions
Description Symbol Min. Nom. Max. Unit
Supply Voltage[2] VCC 4.5 5.0 5.5 V
Operating Temperature, Ambient[1] TA -55 +85 °C
Enable Pulse Width tW 100 nsec
Time Data Must Be Held Before Positive Transition of Enable Line tSETUP 50 nsec
Time Data Must Be Held After Positive Transition of Enable Line tHOLD 50 nsec
Enable Pulse Rise Time tTLH 1.0 msec
Optical Characteristics at TA = 25°C, VCC = 5.0 V
Device Description Symbol Min. Typ. Max. Unit
HDSP-0760 Luminous Intensity per LED (Digit Average)[3,4] IV 65 140 µcd
Series Peak Wavelength lPEAK 635 nm
Dominant Wavelength[5] ld 626 nm
HDSP-0770 Luminous Intensity per LED (Digit Average)[3,4] IV 260 620 µcd
Series Peak Wavelength lPEAK 635 nm
Dominant Wavelength[5] ld 626 nm
HDSP-0860 Luminous Intensity per LED (Digit Average)[3,4] IV 215 490 µcd
Series Peak Wavelength lPEAK 583 nm
Dominant Wavelength[5,6] ld 585 nm
HDSP-0960 Luminous Intensity per LED (Digit Average)[3,4] IV 298 1100 µcd
Series Peak Wavelength lPEAK 568 nm
Dominant Wavelength[5,6] ld 574 nm
Notes:
1. The nominal thermal resistance of a display mounted in a socket that is soldered onto a printed circuit board is RqJA = 50°C/W/device. The
device package thermal resistance is RqJ-PIN = 15°C/W/device. The thermal resistance device pin-to-ambient through the PC board should not
exceed 35°C/W/device for operation at TA = +85°C.
2. Voltage values are with respect to device ground, pin 6.
3. These displays are categorized for luminous intensity with the intensity category designated by a letter code located on the back of the display
package. Case temperature of the device immediately prior to the light measurement is equal to 25°C.