ECONOLINE - DC/DC-Converter RK and RH Series, 1 Watt, SIP7, 3kV/4kV (Single & Dual Output) Features 3kVDC (4kVDC Option) Isolation Power Sharing on Dual Output Efficiency to 78% 1.8, 3.3, 5V, 9V, 12V, 15V and 24V Output Custom Solutions Available UL94V-0 Package Material Selection Guide Part Number SIP 7 Output Voltage (VDC) Output Current (mA) Efficiency (4kV) Input Voltage (VDC) RK-XX1.8S (H) 1.8, 3.3, 5, 9, 12, 15, 24 1.8 555 70 RK-XX3.3S (H) 1.8, 3.3, 5, 9, 12, 15, 24 3.3 303 75 RK-XX05S (H) 1.8, 3.3, 5, 9, 12, 15, 24 5 200 70-78 RK-XX09S (H) 1.8, 3.3, 5, 9, 12, 15, 24 9 111 70-80 RK-XX12S (H) 1.8, 3.3, 5, 9, 12, 15, 24 12 84 78-82 RK-XX15S (H) 1.8, 3.3, 5, 9, 12, 15, 24 15 66 78-82 RK-XX24S (H) 1.8, 3.3, 5, 9, 12, 15, 24 24 42 74-83 RH-XX1.8D (H) 1.8, 3.3, 5, 9, 12, 15, 24 1.8 278 70 RH-XX3.3D (H) 1.8, 3.3, 5, 9, 12, 15, 24 3.3 152 70 RH-XX05D (H) 1.8, 3.3, 5, 9, 12, 15, 24 5 100 70-78 RH-XX09D (H) 1.8, 3.3, 5, 9, 12, 15, 24 9 56 75-80 RH-XX12D (H) 1.8, 3.3, 5, 9, 12, 15, 24 12 42 78-84 RH-XX15D (H) 1.8, 3.3, 5, 9, 12, 15, 24 15 33 80-84 RH-XX24D (H) 1.8, 3.3, 5, 9, 12, 15, 24 24 21 80-84 (%) Specifications (Core Operating Area) and Operating Temperature / Derating-Graph Input Voltage 10% Input Filter Capacitor Type Output Voltage Accuracy 5% Load Voltage Regulation (10% to 100% full load) Ripple and Noise (20MHz limited) 1,2%/1% V Input 1.8V, 3.3V output types 5V output type 9V, 12V, 15V, 24V output types 20% max. 15% max. 10% max. Single output types Dual output types 100mVp-p max. 75mVp-p max. Efficiency at Full Load Isolation Voltage 70% min. 3.000VDC min. (also available with 4.000VDC, Suffix `H') Isolation Resistance (Viso = 500VDC) Isolation Capacitance 15 G min. 20pF min./65pF max. Short Circuit Protection Switching Frequency at Full Load Operating Temperature Storage Temperature 1 Second 1.5 1.0 Safe Operating Area 0.5 0 -40 0 50 100 85 Operating Temperature C 150 125 57kHz min. / 105kHz max. -40C to +85C (see Graph) -55C to +125C Package Weight EC 26 2.0 Output Power (Watts) Line Voltage Regulation 2.8g August 2002 www.recom-international.com ECONOLINE - DC/DC-Converter RK and RH Series, 1 Watt, SIP7, 3kV/4kV (Single & Dual Output) Package Style and Pinning (mm) 3rd angle projection 7 PIN SIP Package, RK-xxxx & RH-xxxx Converters with 3kV Isolation Voltage 19.60 RK & RH Converters with 3kV Isolation 6.00 RH-0512D RECOM **** 10.20 Single Output RH-0512D RECOM **** RK-0512S RECOM **** 0.51 typ. 1 2 0.51 typ. 4.10 Dual Output 5 6 7 1 2 5 7 Footprint Details 1.00 o+0.15/-0 1.00 o+0.15/-0 2.54 1.27 2.0 2.54 0.25 1 2 5 6 7 15.24 2.54 2.54 7 PIN SIP Package, RK-xxxxH & RH-xxxxH Converters with 4kV Isolation Voltage 19.60 7.05 10.20 RH-0512DH RECOM **** 0.51 typ. RH-0512DH RECOM **** RK-0512SH RECOM **** 5 6 7 1 2 5 7 Footprint Details Pin Connections Pin # Single Dual 1 +Vin +Vin 2 -Vin -Vin 1.27 5 1 2 -Vout 6 No Pin 5 6 7-Vout Com 2.07 Single Output 1 2 0.51 typ. 4.10 Dual Output 1.00 o+0.15/-0 2.54 1.00 o+0.15/-0 2.54 0.25 +Vout 15.24 +Vout 2.54 2.54 XX.X 0.5 mm XX.XX 0.25 mm www.recom-international.com August 2002 EC 27