BABT
BABT Approved Relay G6A–BS
BABT Approved Relay Meeting the
Requirements of EN41003:1993 as
endorsed, formerly BS6301:1989
Amendment 5 for Supplementary
Isolation
BABT Approved No. CR/0098.
Height of only 8mm from PCB.
Wide switching load – 10µA to 2A.
Fully sealed construction.
Ordering Information
Single-side Stable Type
Model Classification
G6A–234P–BS Contact
Form – DPDT Contact T
ype – Bifurcated
crossbar
Contact Material –
AgPd+Au clad
Structure – Plastic sealed
Rated coil voltage
Note:
When ordering, add the rated coil voltage to the model number
.
Example: G6A-234P-BS 12 VDC
Specifications
Coil Ratings
General purpose, DPDT Relays
Rated voltage (VDC) 3 4.5 5 6 9 12 24 48
Rated current (mA) 93.8 62.5 56.2 46.5 31.1 23.3 11.7 7.0
Coil resistance (
Ω)32 72 89 129 289 514 2,057 6,882
Coil inductance
Armature OFF 0.07 0.16 0.2 0.29 0.63 1.1 4.5 13.7
(H) (ref. value)
Armature ON 0.065 0.14 0.18 0.26 0.57 1.06 4.1 12.5
Must operate voltage
70% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. voltage
150% of rated voltage at 23
_
C, 150% at 70
_C
Power consumption
Approx. 280 mW
Approx.
330 mW
Contact Ratings
Item G6A-234P-BS
Load Resistive
load
(cos∅
= 1)
Inductive load
(cos∅
= 0.4; L/R = 7 ms)
Rated load
0.3 A at 125 V
AC;
1 A at 30 VDC
0.2 A at 125 V
AC;
0.5 A at 30 VDC
Contact material
AgPd (Au-clad)
Rated carry current
3 A
Max. switching voltage
250 V
AC, 220 VDC
Max. switching current
DC: 2A; AC: 2 A
DC: 1 A; AC: 1 A
Max. switching capacity
125 V
A, 60 W
62.5 V
A, 30 W
Min. permissible load
0.01 mA at 10 mVDC