Previous Vectron Model Numbers C4605
Frequency Range 5 MHz – 20 MHz
Standard Frequencies 5, 10 MHz
Parameter Min Typ Max Units Operating temp range
vs. operating temperature range
(Referenced to +25°C)
-0.4
-0.2
-0.4
+0.4
+0.2
+0.4
ppb
ppb
ppb
0 … +70°C
0 … +70°C
-20 … +70°C
Parameter Min Typ Max Units Condition
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging / 1 day
vs. aging / 1 day
vs. aging / 1 year
-100
-0.2
-0.2
-0.5
-0.2
-25
+100
+0.2
+0.2
+0.5
+0.2
+25
ppb
ppb
ppb
ppb
ppb
ppb
at time of shipment, nominal EFC
VS ± 5%
Load ± 5%
after 72 hours of operation
after 7 days of operation
after 72 hours of operation
Warm-up Time 5 minutes to ± 10ppb of fi nal frequency
(1 hour reading) @ +25°C
DX-170
Oven Controlled Crystal Oscillator
Frequency stabilities1 [SC Cut Crystal)
CDMA2000 and UMTS Base Stations
Test and Measurement Equipment
Ultra-High Stability
Excellent Temperature Stability
SC-Cut Crystal
Features Typical Applications
http://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
DX-170