MEDICAL LINEARS MEDICAL LINEARS FEATURES * * * * * World-wide AC input ranges and safety standards Industry standard packages Approved to UL544, IEC601 and CSA234 L3 Burn-in with cycling; 3-year warranty MTBF over 200,000 hours per Mil-Hdbk 217E SPECIFICATIONS AC Input 100, 120, 220 and 240Vac: +10%, -13%, 47-63Hz. Tolerance for 230Vac operation is +15%, -10%. Derate output current 10% for 50Hz operation. L and LL case units have AC input of 95-132/190-264Vac, 47-63Hz. Range can be extended to 90-132/180-264Vac by derating output current 20%. DC Output See voltage rating chart. Adjustment range 5% minimum. Line Regulation 0.05% for a 10% change. Load Regulation 0.05% for a 50% load change. Output Ripple 3mV +0.05% of output voltage, peak to peak maximum. Transient Response 50 microseconds for 50% load change. Overvoltage Protection Built-in on all 5V models, set at 6.2V 0.4V. Other models use optional * * * * * Medical leakage current does not exceed 10A All electrolytic caps rated at 105C Transformer insulation meets Class F (155C) Exceed FCC and CISPR11 Class B conducted emissions marked to LVD overvoltage protection. OVP is not optional on L and LL case units; however, it is built in on 5V models. Short Circuit Protection Automatic current limit/foldback. Remote Sensing Provided on all models 3 amps and above; open sense lead protection built-in. Stability 0.05% for 24 hours after warmup. Temperature Rating 0 to 50C full rated, derated linearly to 40% at 70C. Temperature Coefficient 0.01%/C maximum. Efficiency 5V units: 45%; 12 and 15V units: 55%; 20 and 24V units: 60%. Vibration Per Mil-Std-810D, Method 514.3, Category 1, Procedure 1. Shock Per Mil-Std-810D, Method 516.3, Procedure III. Condor D.C. Power Supplies, Inc./A subsidiary of SL Industries, Inc. 2311 Statham Parkway, Oxnard, CA 93033 * 800-235-5929 * 805-486-4565 * FAX 805-487-8911 * www.condorpower.com/ 118 Voltage Current Leakage Current ML5-OV-A 5V 1.0A 2.0A Case L MB5-3-OV-A 5V 3.0A 6.0A B MC5-6-OV-A 5V 6.0A 6.0A C D MD5-12/OV-A 5V 12.0A 7.5A ML12-0.5-A 12V 0.5A 2.0A L MB12-1.7-A 12V 1.7A 6.0A B MC12-3.4-A 12V 3.4A 6.0A C MD12-6.8-A 12V 6.8A 7.5A D ML15-0.4-A 15V 0.4A 2.0A L MB15-1.5-A 15V 1.5A 6.0A B MC15-3-A 15V 3.0A 6.0A C MD15-6-A 15V 6.0A 7.5A D ML24-0.28-A 24V 0.28A 2.0A L MB24-1.2-A 24V 1.2A 6.0A B MC24-2.4-A 24V 2.4A 6.0A C MD24-4.8-A 24V 4.8A 7.5A D MB28-1-A 28V 1.0A 6.0A B MC28-2-A 28V 2.0A 6.0A C MD28-4-A 28V 4.0A 7.5A D Model (Dual) Output 1 Output 2 Leakage Current Case MLL12-0.25-A +12V@0.25A -12V@0.25A 2.0A L MLL15-0.2-A +15V@0.20A -15V@0.20A 2.0A L MAA15-0.8-A +12/15V@1.0/0.8A 12/15V@1.0/0.8A 6.0A AA MBB15-1.5-A +12/15V@1.7/1.5A -12/15V@1.7/1.5A 6.0A BB MCC15-3-A +12/15V@3.43/3.0A -12/15V@3.43/3.0A 7.5A CC MAA512-A 5V@2.0A 9-15V@0.5A 6.0A AA MBB512-A 5V@3.0A 9-15V@1.25A 6.0A BB MCC512-A 5V@6.0A 9-15V@2.5A 7.5A CC MAA524-A 5V@2.0A 18-24V@0.3A 6.0A AA MBB524-A 5V@3.0A 18-24V@0.8A 6.0A BB MCC524-A 5V@6.0A 18-24V@2.0A 7.5A CC Model (Triple) Output 1 Output 2 Output 3 Leakage Current Case MTLL-5W-A +5V@0.5A +12 to 15V@0.1A -12 to 15V@0.1A 2.0A L MTAA-16W-A 5V@2.0A +12 to 15V@0.4A -12 to 15V@0.4A 2.0A AA MBAA40W-A 5V@3.0A +12/15V@1.0/0.8A -12/15V@1.0/0.8A 6.0A BAA MCAA60W-A 5V@6.0A +12/15V@1.0/0.8A --12/15V@1.0/0.8A 6.0A D MCBB75W-A 5V@6.0A +12/15V@1.71/1.5A -12/15V@1.7/1.5A 7.5A CBB MEDICAL LINEARS Model (Single) NOTE: For medical linear mechanical specifications, see pp. 56-59. Condor D.C. Power Supplies, Inc./A subsidiary of SL Industries, Inc. 2311 Statham Parkway, Oxnard, CA 93033 * 800-235-5929 * 805-486-4565 * FAX 805-487-8911 * www.condorpower.com/ 119