Nominal capacity @ 0.5 mA, to 2V 0.55 Ah
Rated voltage 3.6 V
Maximum recommended continuous current 5 mA
Maximum pulse current capability 10 mA
Weight 8.8g (0.310 oz)
Volume 2.60 cc
Operating temperature range -55ºC to +85ºC
Li metal content approx. 0.2 g
U.L. Component Recognition MH 12193
SUFFIX- /P TIN PLATED NICKEL PINS
CATALOGUE NO.: 15-2450-41020
TECHNICAL DATA
(Typical values @+25ºC for batteries stored for one year or less)
MODEL TL-2450
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
ADDITIONAL INFORMATION
iXtra - Long Term High Performance
Rev. B 02/11 ECN 1502262
DISCHARGE CHARACTERISTICS @ + 25ºC
6.8 K
~0.5 mA
(0.55 Ah)
11 K
~300 µA
(0.55 Ah)
110 K
~30 µA
(0.5 Ah)
360 K
~10 µA
(0.45Ah)
680 K
~5 µA
(0.42 Ah)
1.8 K
~2 mA
(0.51 Ah)
1.0
1.5
2.0
2.5
3.0
3.5
4.0
1 10 100 1000 10000 100000
Hours
Volts
VOLTAGE VS. TEMPERATURE
2 mA
0.5 mA
30 µA
5 µA
0.1 mA
2.7
2.8
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.6
3.7
-50-30-101030507090
ºC
Volts CAPACITY VS. CURRENT
-30°C
0°C
25°C
50°C
80°C
10.10.01
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
mA
Ah
3.6 V Primary lithium-thionyl chloride (Li-SOCl2)
Fast voltage recovery after long term storage and/or usage
High energy density
High and stable operating voltage
Low self discharge rate
10 years shelf life
Wafer construction
Hermetic glass-to-metal-sealing
Non-flammable electrolyte
Non-restricted for trans
p
ortation
CELL FEATURES
TL-2450
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
iXtra - Long Term High Performance
Rev. B 02/11 ECN 1502262
MAIN APPLICATIONS
Utility meters (elect., water &
gas)
Automatic meter reading
RF systems
Sensors & monitoring systems
Tracking systems
Wireless security systems
Automotive electronics
Industrial electronics
Ultra Low Power
(
ULP
)
Cells should be stored in a
clean & dry (less than 30 %
RH) area
STORAGE CONDITIONS
For updated information please visit
our website www.tadiranbat.com
VOLTAGE RESPONSE AFTER STORAGE
After 1 year
After 2 years
After 5 years
After 10 years
2.6
2.7
2.8
2.9
3.0
3.1
3.2
3.3
3.4
3.5
0 200 400 600 800 1000 1200
msec
Volts
VOLTAGE RESPONSE
After 1 year
After 2 years
After 5 years
After 10 years
3.1
3.2
3.3
3.4
0 20 40 60 80 100 120
msec
Volts VOLTAGE RESPONSE
After 1 year
After 2 years
After 5 years
After 7 years
3.1
3.2
3.3
3.4
0 20 40 60 80 100 120
msec
Volts
Pulse applied: 5 mA for 100 msec
Temperature: RT
Background current: 2 µA
Pulse applied: 5 mA for 100 msec
Temperature: RT
Background current: 4 µA
Pulse applied: 5 mA for 1 sec
Storage: RT
Background current: None