Click on Series name for product info on aimtec.com Series AMEL5-MAZ 5 Watt | AC-DC / DC-DC Converter FEATURES: * * * * I/O Isolation 4000VAC Operating Temp: -40 C to +80 C or -25 C to +80 C Input: 90-264VAC, 47-440Hz, or 130-370VDC Over load, Over Voltage, Short Circuit Protection * * * * RoHS compliant Energy Star compliant Small package Soft start Models Single output Model CB Input Voltage (VDC) Input Voltage (VAC/Hz) Temperature range (C) Output Voltage (V) Efficiency (%) Maximum capacitive Load (F) Output Current max (A) AMEL5-3.3SMAZ 90-264/47-440 130-370 -40 to +80 3.3 1. 5 2200 AMEL5-5SMAZ 90-264/47-440 130-370 -40 to +80 5 1 1100 AMEL5-12SMAZ 90-264/47-440 130-370 -40 to +80 12 0.42 680 AMEL5-15SMAZ 90-264/47-440 130-370 -40 to +80 15 0.333 330 AMEL5-24SMAZ 90-264/47-440 130-370 -40 to +80 24 0.21 220 AMEL5-3.3SEMAZ 90-264/47-440 130-370 -40 to +80 3.3 1. 5 2200 AMEL5-5SEMAZ 90-264/47-440 130-370 -40 to +80 5 1 1100 AMEL5-12SEMAZ 90-264/47-440 130-370 -40 to +80 12 0.42 680 AMEL5-15SEMAZ 90-264/47-440 130-370 -40 to +80 15 0.333 330 AMEL5-24SEMAZ 90-264/47-440 130-370 -40 to +80 24 0.21 220 Note: Optional mounting plate version can be ordered by adding "-ST" suffix to part number (ex. AMEL5-5SMAZ-ST) 115 VAC 230 VAC 71 74 77 77 76 71 74 76 76 76 70 74 75 76 75 70 74 76 76 75 Models Dual output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Temperature range (C) Output Voltage (V) Efficiency (%) Maximum capacitive load (F) Output Current max (A) AMEL5-5DMAZ 90-264/47-440 130-370 -40 to +80 5 0.5 470 AMEL5-12DMAZ 90-264/47-440 130-370 -40 to +80 12 0.21 220 AMEL5-15DMAZ 90-264/47-440 130-370 -40 to +80 15 0.168 150 AMEL5-5DEMAZ 90-264/47-440 130-370 -40 to +80 5 0.5 470 AMEL5-12DEMAZ 90-264/47-440 130-370 -40 to +80 12 0.21 220 AMEL5-15DEMAZ 90-264/47-440 130-370 -40 to +80 15 0.168 150 Note: Optional mounting plate version can be ordered by adding "-ST" suffix to part number (ex. AMEL5-5SMAZ-ST) 115 VAC 230 VAC 72 73 72 72 73 72 72 73 73 72 73 73 Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse Input Dissipation (No Load) Start up time Under Voltage Protection Conditions Typical 115 VAC 230 VAC 115 VAC 230 VAC 1.5 0.1 780 85 Recommended slow blow type No load (110/230VAC) Soft Start Maximum 120 70 15 30 0.2 Units mA mA A A mA A W mS VAC Output Specifications Parameters Conditions Voltage accuracy Line regulation www.aimtec.com F 052e R8.U Typical 2 1 Tel: +1 514 620 2722 1 of 5 Maximum Units % % Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL5-MAZ 5 Watt | AC-DC / DC-DC Converter Load regulation (single output) Cross Regulation (dual output) Transient Recovery Time Transient Response Deviation Minimum load 0-100% load 25% load - 1st out, 100% load - 2nd out 1 5 % % 300 2 0 3.3 / 5V models 75 Ripple & Noise * 12 / 15V models 100 24V 150 Hold-up time (minimum) 15 *Ripple and Noise are measured at 20MHz bandwidth by using a 0.1F (M/C) and 47F (E/C) parallel capacitor. s % of Vout % 25% load step mV p-p ms Isolation Specifications Parameters Tested I/O voltage Isolation Resistance Conditions Typical 60 sec 4000 >1000 Rated Units VAC M General Specifications Parameters Switching frequency Protection class Over Load protection Over voltage protection Short circuit protection Operating temperature Storage temperature Maximum Case temperature Temperature coefficient Cooling Humidity Case material Weight Dimensions (L x W x H) Conditions With derating above 50C Typical Maximum 132 Class II Fold back Zener diode clamp Auto recovery Refer to the models table above -40 to +95 100 0.02 Units KHz oC oC oC % / oC Free air convection Non condensing 20 ~ 95 % RH Plastic (flammability to UL 94V-0) 30 g 2.03 x 1.10 x 0.70 inches 51.5 x 28 x 17.8mm > 400,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load MTBF > 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Shock Vibrations Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) www.aimtec.com F 052e R8.U Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL5-MAZ 5 Watt | AC-DC / DC-DC Converter Safety Specifications Parameters Agency approvals cULus, CE, CB Medical Electrical Equipment Information technology Equipment EMI - Conducted and radiated emission Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Standards IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1-M90 EN 60950-1:2006+A11:2009 EN55032, class B with the recommended External EMI circuit IEC/EN 61000-3-2, Class A IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 Level 3 IEC 61000-4-3 Level 2 IEC 61000-4-4 Level 3 IEC 61000-4-5 Level 3 IEC 61000-4-6 Level 2 IEC 61000-4-8 Level 2 IEC 61000-4-11 Dimensions 2.03 (51.50) 1.80 (45.72) 1 Case Temperature Measurement point 3 1 0.40 (10.16) 1.10 0.80 (28.00) (20.32) TOP VIEW TOP VIEW 4 + 4 0.40 (10.16) 2 5 3 2 5 0.11 (2.89) 17.80 (0.70) 5 O- 0.047 (O 1.2) O 0.04 (1.00) 0.2 (5.08) (Min) DIV: 0.2 (5.08) Dimensions: inch (mm) Case Tolerance: 0.02 (0.50) Pin Pitch Tolerance: 0.012 (0.30) Pin Out Specifications Derating Pin Single Dual 1 2 3 4 5 AC Input (N) AC Input (L) +V Output -V Output No pin AC Input (N) AC Input (L) +V Output Common -V Output Free Air Convection 50 C 100 80 Safe Operating Area 60 70C 50% 40 25% 80C 20 0 - 40 - 25 - 20 0 20 40 60 80 100 Ambient Temperature C www.aimtec.com F 052e R8.U Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL5-MAZ 5 Watt | AC-DC / DC-DC Converter Additional Surge Protective Circuitry The AMEL5-MAZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However greater protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal Oxide Varistor) device example TVR10471KSY to the N / L input lines 2KV surge protection or greater, can be achieved. Fuse + Vo+ Aimtec AC-DC Converter MOV N - Load L Vo- MOV PN Vrms V Vdc V Wmax (2ms) J Pmax W TVR10471KSY 300 385 70 0.4 Recommended EMI Circuit for Dual output models LCM AC L AC L + Vout +Vout CY1 AC CX Common DC CY2 AC N AC N - Vout - Vout GND CX LCM PN CY1/CY2 330nF/275VAC 2mH, Recommended SU9V-05020 1000pF/400VAC www.aimtec.com F 052e R8.U Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL5-MAZ 5 Watt | AC-DC / DC-DC Converter Dimensions of Optional ST Mounting Plate Version Pin Out Specification ST Version 86.00 38.00 25.00 70.00 AIMTEC NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec's standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.U Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only