Series AMEL5-MAZ
5 Watt | AC-DC / DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052e R8.U 1 of 5 North America only
FEATURES:
Models
Single output
Model
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
Output
Voltage
(V)
Output
Current max
(A)
Maximum
capacitive
Load
(µF)
115
VAC
230
VAC
AMEL5-3.3SMAZ
90-264/47-440
130-370
-40 to +80
3.3
1. 5
2200
71
70
AMEL5-5SMAZ
90-264/47-440
130-370
-40 to +80
5
1
1100
74
74
AMEL5-12SMAZ
90-264/47-440
130-370
-40 to +80
12
0.42
680
77
75
AMEL5-15SMAZ
90-264/47-440
130-370
-40 to +80
15
0.333
330
77
76
AMEL5-24SMAZ
90-264/47-440
130-370
-40 to +80
24
0.21
220
76
75
AMEL5-3.3SEMAZ
90-264/47-440
130-370
-40 to +80
3.3
1. 5
2200
71
70
AMEL5-5SEMAZ
90-264/47-440
130-370
-40 to +80
5
1
1100
74
74
AMEL5-12SEMAZ
90-264/47-440
130-370
-40 to +80
12
0.42
680
76
76
AMEL5-15SEMAZ
90-264/47-440
130-370
-40 to +80
15
0.333
330
76
76
AMEL5-24SEMAZ
90-264/47-440
130-370
-40 to +80
24
0.21
220
76
75
Note: Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL5-5SMAZ-ST)
Models
Dual output
Model
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
Output
Voltage
(V)
Output
Current max
(A)
Maximum
capacitive
load
(µF)
115
VAC
230
VAC
AMEL5-5DMAZ
90-264/47-440
130-370
-40 to +80
±5
±0.5
±470
72
72
AMEL5-12DMAZ
90-264/47-440
130-370
-40 to +80
±12
±0.21
±220
73
73
AMEL5-15DMAZ
90-264/47-440
130-370
-40 to +80
±15
±0.168
±150
72
73
AMEL5-5DEMAZ
90-264/47-440
130-370
-40 to +80
±5
±0.5
±470
72
72
AMEL5-12DEMAZ
90-264/47-440
130-370
-40 to +80
±12
±0.21
±220
73
73
AMEL5-15DEMAZ
90-264/47-440
130-370
-40 to +80
±15
±0.168
±150
72
73
Note: Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL5-5SMAZ-ST)
Input Specifications
Parameters
Conditions
Typical
Maximum
Units
Current (full load)
115 VAC
120
mA
230 VAC
70
mA
Inrush current <2ms (cold start)
115 VAC
15
A
230 VAC
30
A
Leakage current
0.2
mA
External fuse
Recommended slow blow type
1.5
A
Input Dissipation (No Load)
No load (110/230VAC)
0.1
W
Start up time
Soft Start
780
mS
Under Voltage Protection
85
VAC
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
±2
%
Line regulation
±1
%
I/O Isolation 4000VAC
RoHS compliant
Operating Temp: -40 °C to +80 °C or -25 °C to +80 °C
Energy Star compliant
Input: 90-264VAC, 47-440Hz, or 130-370VDC
Small package
Over load, Over Voltage, Short Circuit Protection
Soft start
CB
Click on Series name for product info on aimtec.com
Series AMEL5-MAZ
5 Watt | AC-DC / DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052e R8.U 2 of 5 North America only
Load regulation (single output)
0-100% load
±1
%
Cross Regulation (dual output)
25% load 1st out, 100% load 2nd
out
±5
%
Transient Recovery Time
300
µs
Transient Response Deviation
25% load step
±2
% of Vout
Minimum load
0
%
Ripple & Noise *
3.3 / 5V models
12 / 15V models
24V
75
100
150
mV p-p
Hold-up time (minimum)
15
ms
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1µF (M/C) and 47µF (E/C) parallel capacitor.
Isolation Specifications
Parameters
Conditions
Typical
Rated
Units
Tested I/O voltage
60 sec
4000
VAC
Isolation Resistance
>1000
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
132
KHz
Protection class
Class II
Over Load protection
Fold back
Over voltage protection
Zener diode clamp
Short circuit protection
Auto recovery
Operating temperature
With derating above 50ºC
Refer to the models table above
oC
Storage temperature
-40 to +95
oC
Maximum Case temperature
100
oC
Temperature coefficient
0.02
% / oC
Cooling
Free air convection
Humidity
Non condensing
20 ~ 95
% RH
Case material
Plastic (flammability to UL 94V-0)
Weight
30
g
Dimensions (L x W x H)
2.03 x 1.10 x 0.70 inches 51.5 x 28 x 17.8mm
MTBF
> 400,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
> 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Parameters
Conditions
Shock
Wave form: Half sine wave
Acceleration amplitude: 5gn
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Vibrations
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Series AMEL5-MAZ
5 Watt | AC-DC / DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052e R8.U 3 of 5 North America only
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB
Standards
Medical Electrical Equipment
IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1-M90
Information technology Equipment
EN 60950-1:2006+A11:2009
EMI - Conducted and radiated emission
EN55032, class B with the recommended External EMI circuit
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2 Level 3
RF, Electromagnetic Field Immunity
IEC 61000-4-3 Level 2
Electrical Fast Transient/Burst Immunity
IEC 61000-4-4 Level 3
Surge Immunity
IEC 61000-4-5 Level 3
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 2
Power frequency Magnetic Field Immunity
IEC 61000-4-8 Level 2
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
Dimensions
Pin Out Specifications Derating
Pin
Single
Dual
1
AC Input (N)
AC Input (N)
2
AC Input (L)
AC Input (L)
3
+V Output
+V Output
4
-V Output
Common
5
No pin
-V Output
DIV: 0.2 (5.08)
5 Ø- 0.047 (Ø 1.2)
TOP VIEW
1
2
3
4
5
Dimensions: inch (mm)
Case Tolerance:± 0.02 (0.50)
Pin Pitch Tolerance: ± 0.012 (0.30)
1.10
(28.00)
0.40
(10.16)
0.40
(10.16)
2.03
(51.50)
1.80
(45.72)
0.80
(20.32)
0.11
(2.89)
TOP VIEW
1
2
3
4
5
17.80
(0.70)
0.2
(5.08)
(Min)
Ø 0.04
(1.00)
+
Case Temperature
Measurement point
-40 -20 020 40 60 80 100
100
80
60
40
20
0
50 º C
Safe Operating Area
-25
Free Air Convection
Ambient Temperature º C
25%
50%70C
80C
Series AMEL5-MAZ
5 Watt | AC-DC / DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052e R8.U 4 of 5 North America only
Additional Surge Protective Circuitry
The AMEL5-MAZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However
greater protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal
Oxide Varistor) device example TVR10471KSY to the N / L input lines 2KV surge protection or greater, can be achieved.
Aimtec
AC-DC
Converter
Load
L
N
+
-
Vo+
Vo-
MOV
Fuse
Recommended EMI Circuit for Dual output models
AC L
AC N
AC DC
+Vout
- Vout
AC L
AC N
+ Vout
- Vout
CY2
CX
LCM
Common
CY1
GND
MOV PN
Vrms
V
Vdc
V
Wmax (2ms)
J
Pmax
W
TVR10471KSY
300
385
70
0.4
CX
LCM PN
CY1/CY2
330nF/275VAC
2mH, Recommended SU9V-05020
1000pF/400VAC
Series AMEL5-MAZ
5 Watt | AC-DC / DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052e R8.U 5 of 5 North America only
Dimensions of Optional ST Mounting Plate Version
70.00
86.00
38.00
25.00
AIMTEC
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
Pin Out Specification ST
Version